This manual provides detailed instructions for the installation, operation, and maintenance of your AIDA Single Pole Motion Sensor Light Switch. This device is designed to enhance convenience and energy efficiency by automatically controlling lighting based on occupancy. Please read this manual thoroughly before installation and use to ensure proper function and safety.
Image: The AIDA Single Pole Motion Sensor Light Switch shown alongside its product packaging, highlighting its design and key features.
ข้อมูลด้านความปลอดภัยที่สำคัญ
WARNING: RISK OF ELECTRIC SHOCK. Improper installation can be dangerous or illegal. Always consult a qualified electrician if you are unsure about any part of the installation process.
- ปิดไฟ: Always disconnect power at the circuit breaker or fuse box before installing or servicing the switch.
- ต้องการลวดเป็นกลาง: This device requires a neutral wire for proper operation. If your electrical box does not have a neutral wire, this switch is not compatible.
- ใช้ได้เฉพาะเสาเดี่ยวเท่านั้น: This switch is designed for single-pole control only and is not suitable for 3-way or multiple-way circuits.
- UL/CUL Certified: The switch is UL and CUL listed, ensuring compliance with safety standards.
- ปฏิบัติการฉบับที่tage: Ensure your electrical system operates at 120 Volts (AC).
เนื้อหาแพ็คเกจ
ตรวจสอบว่าส่วนประกอบทั้งหมดมีอยู่ก่อนเริ่มการติดตั้ง:
- AIDA Single Pole Occupancy Motion Sensor Light Switch
- แผ่นผนังไร้สกรู
- Wire Nuts (Terminal caps)
- สกรูยึด
- คู่มือการใช้งาน (เอกสารนี้)
ข้อมูลจำเพาะผลิตภัณฑ์
| คุณสมบัติ | รายละเอียด |
|---|---|
| คะแนนอินพุต | 120/277V~50/60Hz |
| Applicable Load Types | 200W LED/CFL, 500W MLV, 500W INC/HAL, 5A Ballast (120V), 1/6HP Fan (4.4A 120V) |
| ประเภทสวิตซ์ | เสาเดี่ยว |
| เครื่องวัดสายไฟ | #14 - #12 AWG |
| ประเภทสายไฟ | ฝาครอบขั้ว |
| อุณหภูมิในการทำงาน | 32°F ถึง 104°F (0°C ถึง 40°C) |
| ขนาดสินค้า | 4.17"x1.73"x1.77" (106x44x45mm) |
| วัสดุ | ทองแดง, ทองเหลือง (วัสดุสัมผัส) |
| วิธีการควบคุม | Sensor, Touch |
Image: A visual representation of the product dimensions and a detailed table of specifications for the AIDA motion sensor switch.
Image: A chart illustrating the universal compatibility of the AIDA motion sensor switch with various load types including LED/CFL, MLV, INV/HAL, Ballast, and Fan.
การติดตั้งและการตั้งค่า
ก่อนที่คุณจะเริ่มต้น:
- ปิดไฟ: Locate your circuit breaker panel and turn off the power to the switch box you will be working on. Verify power is off using a voltagอีผู้ทดสอบ
- ระบุสายไฟ: Carefully remove the existing wall plate and switch. Identify the following wires:
- Line Wire (Black): รับกระแสไฟฟ้าจากเบรกเกอร์วงจร
- Load Wire (Black): Carries power to the light fixture.
- สายกลาง (สีขาว): Required for this switch.
- Ground Wire (Green or Bare Copper): เพื่อความปลอดภัย
- Confirm Neutral Wire: This switch requires a neutral wire. If you do not have a neutral wire (typically white) in your electrical box, this switch is not compatible.
คำแนะนำในการเดินสายไฟ:
Follow the wiring diagram carefully. Use the provided wire nuts to secure connections.
Image: A detailed wiring diagram showing connections for the AIDA motion sensor light switch, including Line, Load, Neutral, and Ground wires. It explicitly states that a neutral wire is required and the switch is not suitable for 3-way or multiple-way circuits.
- เชื่อมต่อ สีเขียว wire from the switch to your house's พื้น ลวด.
- เชื่อมต่อ สีขาว wire from the switch to your house's เป็นกลาง ลวด.
- เชื่อมต่อ สีดำ wire from the switch to your house's เส้น ลวด (ร้อน)
- เชื่อมต่อ สีแดง wire from the switch to your house's โหลด wire (to the light fixture).
Important: Ensure all connections are secure and insulated with wire nuts. This switch is for single-pole applications only. Do not use in 3-way or multi-way circuits.
การติดตั้งสวิตช์:
- Carefully fold the wires and push the switch into the electrical box.
- Secure the switch to the electrical box using the provided screws.
- Attach the screwless wall plate.
- เรียกคืนพลังงานที่เบรกเกอร์
Image: A diagram showing the precise dimensions of the AIDA motion sensor light switch, its mounting bracket, and the screwless wall plate for easy installation.
Operating Instructions and Customization
The AIDA motion sensor switch offers various modes and adjustable settings to suit your needs.
โหมดการทำงาน:
- Occupancy Mode (Auto-On/Auto-Off): Lights automatically turn ON when motion is detected and OFF after a set delay when no motion is detected. Ideal for high-traffic areas like bathrooms, laundry rooms, and kitchens.
- Vacancy Mode (Manual-On/Auto-Off): Lights must be manually turned ON, but will automatically turn OFF after a set delay when no motion is detected. Suitable for bedrooms or TV rooms where you prefer manual control for turning on lights.
การตั้งค่าที่ปรับได้:
The switch features internal dip switches for customizing settings. Carefully remove the faceplate to access these controls.
ภาพ: ภาพระยะใกล้ view of the AIDA motion sensor switch's internal settings, showing dip switches for Adjustable Light Level (Timeout), PIR Sensitivity, and Ambient Light Sensor Mode.
- Adjustable Light Level (Timeout): This setting determines how long the light stays on after the last detected motion. Options typically include 30 seconds, 1 minute, 5 minutes, 15 minutes, or 30 minutes. Refer to the switch's internal labels for specific settings.
- ความไว PIR: Adjusts the sensitivity of the Passive Infrared (PIR) sensor to detect motion. Settings range from Low (L) to High (H). A higher sensitivity detects smaller movements or movements at a greater distance.
- Ambient Light Sensor Mode: Controls how the switch reacts to ambient light.
- ต่ำ/สูง: The switch will only turn on lights if the ambient light level is below a certain threshold (e.g., only turn on at night).
- ปิด: The ambient light sensor is disabled, and the switch will turn on lights regardless of ambient light.
- กำหนดเอง: Allows for more specific ambient light level adjustments.
Note: After adjusting any internal settings, reattach the faceplate securely.
ภาพ: รายละเอียด view of the AIDA motion sensor switch with its cover removed, showing the dip switches for adjusting timeout, PIR sensitivity, and ambient light sensor mode.
การซ่อมบำรุง
The AIDA Motion Sensor Light Switch is designed for long-lasting, maintenance-free operation. To ensure optimal performance:
- การทำความสะอาด: Periodically wipe the switch and wall plate with a soft, damp ผ้า ห้ามใช้น้ำยาทำความสะอาดที่มีฤทธิ์กัดกร่อนหรือตัวทำละลาย เพราะอาจทำให้พื้นผิวหรือส่วนประกอบภายในเสียหายได้
- สิ่งกีดขวาง: Ensure the sensor lens is not obstructed by furniture, decorations, or other objects, as this can impair motion detection.
- ไม่มีชิ้นส่วนที่ผู้ใช้สามารถซ่อมบำรุงได้: There are no user-serviceable parts inside the switch. Do not attempt to open or repair the unit beyond adjusting the dip switches.
การแก้ไขปัญหา
| ปัญหา | สาเหตุที่เป็นไปได้ | สารละลาย |
|---|---|---|
| Light does not turn ON with motion. |
|
|
| Light stays ON constantly. |
|
|
| Light turns OFF too quickly or too slowly. |
|
|
| Switch makes a clicking noise. |
|
|
การรับประกันและการสนับสนุนลูกค้า
AIDA products are manufactured to high-quality standards and are backed by a limited warranty. For specific warranty details, please refer to the warranty card included with your purchase or visit the official AIDA webเว็บไซต์.
If you encounter any issues or have questions regarding your AIDA Single Pole Motion Sensor Light Switch, please contact our customer support team:
- Webเว็บไซต์: Visit the AIDA Store on Amazon (สำหรับข้อมูลผลิตภัณฑ์ทั่วไป)
- อีเมล: โปรดดูที่บรรจุภัณฑ์ของผลิตภัณฑ์หรือเอกสารอย่างเป็นทางการ webเว็บไซต์สำหรับติดต่ออีเมล์
- โทรศัพท์: โปรดดูที่บรรจุภัณฑ์ของผลิตภัณฑ์หรือเอกสารอย่างเป็นทางการ webเว็บไซต์สำหรับเบอร์โทรศัพท์ติดต่อ
Please have your model number (B0DM4SGNBQ) and purchase date ready when contacting support.