ACiQ B0DHFF2DKL

คู่มือผู้ใช้ระบบปั๊มความร้อนอินเวอร์เตอร์กลาง ACiQ 2.5 ตัน 17 SEER2

Model: B0DHFF2DKL

1. บทนำ

This manual provides essential information for the installation, operation, and maintenance of your ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System. This system is designed to provide efficient heating and cooling for residential and light commercial applications. Please read this manual thoroughly before attempting any installation or operation to ensure proper function and safety.

2. ข้อมูลด้านความปลอดภัย

Always prioritize safety. Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or death. Consult a qualified installer, service agency, or the gas supplier for information or assistance. The information contained in this manual is intended for use by qualified service personnel only.

  • ความปลอดภัยทางไฟฟ้า: Ensure the power supply is disconnected before performing any service or maintenance. All electrical wiring must comply with local and national electrical codes.
  • การจัดการสารทำความเย็น: This system uses R-454B refrigerant. Only certified technicians should handle refrigerants.
  • การติดตั้ง: Installation must be performed by a licensed HVAC professional.
  • อุปกรณ์ป้องกันภัยส่วนบุคคล: Always wear appropriate personal protective equipment (PPE) such as gloves and safety glasses during installation and maintenance.

3. คุณสมบัติหลัก

  • เทคโนโลยีอินเวอร์เตอร์: Provides precise temperature control, reduced energy consumption, and quieter operation.
  • ประสิทธิภาพสูง: 18.8 SEER2 and 9.7 HSPF2 ratings for energy savings.
  • ช่วงการทำงานกว้าง: Reliable performance from -13°F to 122°F.
  • การทำงานที่เงียบ: Indoor noise levels as low as 44 dBA, outdoor unit at 60 dBA.
  • ส่วนประกอบที่ทนทาน: Rotary compressor, aluminum coil, and fiberglass-free insulation.
  • สารทำความเย็นที่เป็นมิตรต่อสิ่งแวดล้อม: Utilizes R-454B refrigerant.
  • การติดตั้งแบบยืดหยุ่น: Supports horizontal and vertical air handler installation.
  • การควบคุมอัจฉริยะ: Compatible with wired controllers, WiFi, and third-party thermostats.
  • Integrated Back-up Heat: Includes a 10kW back-up heat kit for supplemental heating.

4. ส่วนประกอบมากกว่าview

The ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System includes the following main components:

  • Outdoor Condensing Unit (Heat Pump)
  • หน่วยจัดการอากาศภายในอาคาร
  • 10kW Back-up Heat Kit
  • 30' Line Set
  • Gauge Electrical Whip
  • 60A Non-Fused Disconnect Switch
  • WiFi เทอร์โมสตัท
  • อุปกรณ์ป้องกันไฟกระชาก
  • CPS Charging Adapter
  • แขนติดผนัง
ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System components

รูปที่ 1: เกินview of the ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System, showing the outdoor unit, indoor air handler, 10kW back-up heat kit, thermostat, line set, and various installation accessories.

5. การตั้งค่าและการติดตั้ง

Installation of this ACiQ heat pump system requires specialized knowledge and tools. It must be performed by a qualified and licensed HVAC technician to ensure safety, compliance with local codes, and optimal performance. Refer to the detailed installation manual provided with the product for specific instructions.

5.1 การตรวจสอบก่อนการติดตั้ง

  • Verify that the electrical supply matches the unit's requirements (Indoor: 115/208/230V, 60Hz, 1Ph; Outdoor: 208/230V, 60Hz, 1Ph).
  • ตรวจสอบให้แน่ใจว่ามีพื้นที่เพียงพอสำหรับทั้งยูนิตภายในและภายนอกอาคาร เพื่อให้มีการระบายอากาศที่เหมาะสมและเข้าถึงการบำรุงรักษาได้ง่าย
  • Confirm that the maximum piping length (164 ft / 50m) and height difference (82 ft / 25m) are not exceeded.

5.2 Air Handler Installation

The indoor air handler unit is designed for flexible installation, supporting upflow, downflow, and horizontal configurations to suit various space requirements.

Multi-Positional Air Handler Unit installation options

รูปที่ 2: Diagram illustrating the multi-positional capabilities of the indoor air handler unit, showing options for upflow, downflow, and horizontal installation.

5.3 การจัดวางยูนิตภายนอก

Consider the outdoor unit's dimensions and required clearances for optimal performance and maintenance. The unit features a compact design compared to traditional systems.

Outdoor unit size comparison with traditional units

รูปที่ 3: Graphic comparing the smaller footprint of the ACiQ outdoor unit (20 inches clearance) versus a traditional unit (36 inches clearance), highlighting its high efficiency and self-cleaning features.

6. คู่มือการใช้งาน

Your ACiQ heat pump system offers advanced control options for comfortable and efficient operation.

6.1 โหมดการทำงานพื้นฐาน

  • โหมดทำความเย็น: Provides cooling with a capacity of 31,000 BTU/hr. Operates efficiently from -13°F to 122°F ambient temperatures.
  • โหมดการให้ความร้อน: Provides heating with a capacity of 30,000 BTU/hr at 47°F. Reliable warmth down to -13°F. The 10kW back-up heat kit provides supplemental heat when needed.
  • โหมดพัดลม: หมุนเวียนอากาศโดยไม่ใช้ความร้อนหรือความเย็น
  • โหมดอัตโนมัติ: ระบบจะสลับระหว่างโหมดทำความร้อนและทำความเย็นโดยอัตโนมัติเพื่อรักษาระดับอุณหภูมิที่ตั้งไว้
ACiQ outdoor unit operating in extreme heat

รูปที่ 4: The ACiQ outdoor unit installed on a patio, demonstrating its ability to operate effectively in extreme heat conditions, up to 122°F.

ACiQ outdoor unit operating in extreme cold

รูปที่ 5: The ACiQ outdoor unit partially covered in snow, illustrating its capability to operate in extreme cold temperatures, down to -13°F.

6.2 Smart Controls

The system can be controlled via the included wired thermostat, WiFi-enabled app, or compatible third-party thermostats. The WiFi app allows for remote control and monitoring of your system.

ACiQ Smart Home app and wired thermostat

รูปที่ 6: Image showing the ACiQ Smart Home mobile application interface on a smartphone alongside a wired thermostat, demonstrating the system's smart control capabilities for climate management.

7. การบำรุงรักษา

Regular maintenance ensures the longevity and efficiency of your ACiQ heat pump system. Always disconnect power before performing any maintenance.

  • การเปลี่ยนไส้กรองอากาศ: Check and replace air filters in the indoor air handler every 1-3 months, or more frequently if needed. Dirty filters restrict airflow and reduce efficiency.
  • การทำความสะอาดยูนิตภายนอก: Keep the outdoor unit free from debris, leaves, and dirt. Periodically clean the coils with a soft brush or water hose (ensure power is off).
  • ระบบระบายน้ำ: Ensure the condensate drain line is clear and free of blockages to prevent water overflow.
  • การตรวจสอบอย่างมืออาชีพ: Schedule annual inspections and maintenance by a qualified HVAC technician.

8 การแก้ไขปัญหา

This section provides solutions for common issues. For complex problems, contact a qualified HVAC technician.

  • ไม่มีไฟฟ้า: Check circuit breakers and ensure the disconnect switch is in the ON position.
  • ระบบทำความร้อน/ความเย็นไม่เพียงพอ: Verify thermostat settings, check air filters for blockage, and ensure outdoor unit is not obstructed.
  • เสียงที่ผิดปกติ: Minor operational noises are normal. Loud or unusual noises may indicate a problem requiring professional inspection.
  • น้ำรั่ว: Check condensate drain line for blockages.

9. ข้อมูลจำเพาะ

Dimensions of ACiQ indoor and outdoor units

รูปที่ 7: Image displaying the dimensions of both the indoor air handler unit (49.02" H x 21.02" W x 21.02" D) and the outdoor condensing unit (35.04" H x 37.24" W x 16.14" D).

Cooling capacity chart for ACiQ heat pump

รูปที่ 8: Chart detailing the cooling capacity of the ACiQ system at various outdoor temperatures: 86°F (118% capacity), 95°F (113% capacity), 110°F (99% capacity), and 122°F (48% capacity).

Heating capacity chart for ACiQ heat pump

รูปที่ 9: Chart detailing the heating capacity of the ACiQ system at various outdoor temperatures: -22°F (N/A), -13°F (41% capacity), 0°F (57% capacity), 17°F (70% capacity), and 32°F (73% capacity).

คุณสมบัติรายละเอียด
ความสามารถในการทำความเย็น31,000 บีทียู/ชม.
ความสามารถในการให้ความร้อน30,000 BTU/hr (at 47°F)
เรตติ้ง SEER218.8
คะแนน HSPF29.7
ประเภทสารทำความเย็นอาร์-454บี
แหล่งจ่ายไฟหน่วยในร่ม115/208/230V, 60Hz, 1Ph
Outdoor Unit Power Supply208/230V, 60Hz, 1 เฟส
ความยาวท่อสูงสุด164 ฟุต (50 เมตร)
Max Height Difference82 ฟุต (25 เมตร)
Indoor Unit Dimensions (W × D × H)21.02" × 21.02" × 49.02"
Outdoor Unit Dimensions (W × D × H)37.24" × 16.14" × 31.89"
น้ำหนักสุทธิของชุดภายในอาคาร128.97 ปอนด์
น้ำหนักสุทธิของชุดภายนอก164.02 ปอนด์

10. การรับประกันและการสนับสนุน

ACiQ offers a comprehensive warranty for this heat pump system:

  • การรับประกันชิ้นส่วน: 7 ปี
  • การรับประกันคอมเพรสเซอร์: 12 ปี

These warranty terms are valid when the system is installed by a certified technician and registered online with the manufacturer. For technical support, service inquiries, or warranty claims, please refer to the contact information provided in your product packaging or visit the official ACiQ webเว็บไซต์.

เอกสารที่เกี่ยวข้อง - B0DHFF2DKL

พรีview ระบบทำความร้อนแบบโซนเดียว ACiQ 9K-24K มาตรฐาน: คู่มือการติดตั้งและการใช้งาน
คู่มือการติดตั้งและการใช้งานระบบปรับอากาศแบบโซนเดียว รุ่น ACiQ 9K-24K คู่มือนี้ให้รายละเอียดเกี่ยวกับการติดตั้ง การใช้งาน ความปลอดภัย และการบำรุงรักษาเครื่องปรับอากาศ ACiQ รวมถึงข้อมูลเฉพาะรุ่นและข้อมูลเกี่ยวกับสารทำความเย็น R454B
พรีview ACiQ Central Inverter Systems Installation Manual
Comprehensive installation manual for ACiQ Central Inverter Air Conditioning and Heat Pump Systems, detailing safety precautions, refrigerant piping, outdoor unit installation, wiring, power specifications, air evacuation, and test run procedures.
พรีview คู่มือการติดตั้งและการใช้งานเครื่องปรับอากาศติดผนัง ACiQ และคอนเดนเซอร์แบบโซนเดียวสำหรับสภาพอากาศร้อนจัด
คู่มือนี้ให้คำแนะนำโดยละเอียดเกี่ยวกับการติดตั้ง การใช้งาน และความปลอดภัยสำหรับเครื่องปรับอากาศแบบติดผนัง ACiQ และคอนเดนเซอร์แบบโซนเดียวสำหรับสภาพอากาศร้อนจัด ครอบคลุมรุ่น ACIQ-06W-HH-MD ถึง ACIQ-24ZPL-HP230C
พรีview คู่มือการติดตั้งชุดอุปกรณ์ภายนอกของระบบอินเวอร์เตอร์ส่วนกลาง ACiQ
คู่มือการติดตั้งที่ครอบคลุมสำหรับหน่วยกลางแจ้งระบบอินเวอร์เตอร์ส่วนกลาง ACiQ ครอบคลุมถึงข้อควรระวังด้านความปลอดภัย ท่อสารทำความเย็น สายไฟ การติดตั้งหน่วย และขั้นตอนการทดสอบสำหรับรุ่นต่างๆ เช่น ACiQ-18-AC, ACiQ-24-AC, ACiQ-18-EHPB และอื่นๆ
พรีview ระบบปั๊มความร้อนแบบท่อ ACiQ Next Gen: คู่มือเริ่มต้นใช้งานฉบับย่อสำหรับการเดินสายเทอร์โมสตัท
คู่มือนี้ให้ข้อมูลสำคัญสำหรับการเชื่อมต่อและเดินสายเทอร์โมสตัทเข้ากับระบบปั๊มความร้อนแบบท่อ ACiQ Next Gen อธิบายรายละเอียดเกี่ยวกับตัวเลือกการเชื่อมต่อที่แนะนำและทางเลือกอื่นๆ รวมถึงการตั้งค่าสวิตช์ DIP และการกำหนดค่าบล็อกเทอร์มินัลสำหรับเทอร์โมสตัทประเภทต่างๆ
พรีview คู่มือการติดตั้งและการใช้งานเครื่องปรับอากาศแบบแยกส่วน ACiQ Essentials ทั้งชุดเครื่องปรับอากาศและคอนเดนเซอร์
คู่มือการติดตั้งและการใช้งานฉบับสมบูรณ์สำหรับระบบเครื่องปรับอากาศแบบแยกส่วน ACiQ Essentials ครอบคลุมถึงข้อควรระวังด้านความปลอดภัย การระบุชิ้นส่วน การใช้งานรีโมทคอนโทรล ขั้นตอนการติดตั้ง การทดสอบการทำงาน การบำรุงรักษา และการแก้ไขปัญหาสำหรับรุ่นต่างๆ คู่มือนี้ยังรวมถึงข้อมูลสำคัญเกี่ยวกับการซ่อมบำรุงระบบที่ใช้สารทำความเย็นไวไฟ R454B โดยเน้นโปรโตคอลด้านความปลอดภัยและการปฏิบัติตามกฎระเบียบ คู่มือนี้ออกแบบมาสำหรับช่างติดตั้งมืออาชีพและผู้ใช้งานทั่วไป เพื่อให้มั่นใจได้ถึงการทำงานที่ปลอดภัยและมีประสิทธิภาพของระบบปั๊มความร้อนแบบแยกส่วน ACiQ