MSR Guardian Gravity Purifier

คู่มือผู้ใช้เครื่องกรองน้ำ MSR Guardian Gravity

Model: Guardian Gravity Purifier

แบรนด์: MSR

สินค้าเกินview

The MSR Guardian Gravity Water Purifier is a state-of-the-art, high-volume gravity-fed system designed for backcountry use, global travel, and emergency preparedness. It utilizes advanced hollow-fiber technology to remove viruses, bacteria, protozoa, sediment, and microplastics from challenging water sources. An integrated activated carbon stage further reduces chemicals, unpleasant tastes, and odors, providing clean and better-tasting water.

This system includes a two-stage purifier, a 10-liter dirty water reservoir, a universal bottle adapter, hoses, and a zippered carry case. It boasts a lifetime capacity of up to 3000 liters and can purify up to 1 liter of water in 2 minutes under optimal conditions.

MSR Guardian Gravity Water Purifier components laid out

Image: The MSR Guardian Gravity Water Purifier system, showing the 10-liter dirty water bag, the purification cartridge, and connecting hoses, along with the universal bottle adapter.

คำแนะนำการตั้งค่า

  1. แกะส่วนประกอบ: Carefully remove all components from the zippered carry case: the 10-liter dirty water reservoir, the purification cartridge, hoses, and the universal bottle adapter.
  2. เชื่อมต่อท่อ: Attach the longer hose to the "dirty water" inlet on the purification cartridge (usually marked with an arrow pointing towards the filter). Attach the shorter hose to the "clean water" outlet (arrow pointing away from the filter). Ensure all connections are secure.
  3. Fill Dirty Water Reservoir: Open the top of the 10-liter dirty water reservoir and fill it with untreated water from your source. Ensure the top is securely rolled down and clipped to prevent leaks.
  4. Attach Reservoir to Filter: Connect the dirty water hose from the purification cartridge to the outlet on the bottom of the dirty water reservoir.
  5. Position for Gravity Flow: Hang the filled dirty water reservoir at least 6 feet (approximately 1.8 meters) above your clean water collection container. This height is crucial for optimal flow rate.
  6. Prepare Clean Water Collection: Place your clean water bottle, hydration reservoir, or other container below the purification cartridge's clean water outlet. The universal bottle adapter can be used to directly connect to various bottle types.
People using the MSR Guardian Gravity Water Purifier in an outdoor setting

Image: Individuals setting up and using the MSR Guardian Gravity Water Purifier, demonstrating the hanging of the dirty water bag and collection of purified water into a bottle.

คำแนะนำการใช้งาน

Once the system is set up, the MSR Guardian Gravity Purifier operates by gravity. No pumping is required.

  1. เริ่มกระบวนการ: Ensure the clean water outlet hose is positioned into your collection container. Open any clamps or valves on the clean water hose to allow water to begin flowing through the purification cartridge.
  2. Monitor Flow Rate: Water will flow from the dirty water reservoir, through the filter, and into your clean container. The system is designed for a fast flow rate, purifying up to 1 liter in 2 minutes under ideal conditions.
  3. ฟังก์ชั่นล้าง: If the flow rate decreases significantly, the system features a dedicated purge hose to restore flow. Locate the purge hose (often a small, separate tube or valve on the filter). Open the purge valve or unclamp the purge hose to allow a small amount of dirty water to flush out contaminants from the filter. Close the purge valve/clamp once flow is restored. This should be done periodically, especially after filtering heavily turbid water.
  4. การเติม: When the dirty water reservoir is empty, close the clean water outlet valve, detach the reservoir, and refill it with untreated water as needed.
Diagram illustrating the hollow fiber membrane filtration process

Image: A diagram showing how the advanced hollow fiber membrane physically traps contaminants, including viruses, protozoa, and bacteria, ensuring ultimate viral protection.

Diagram showing the activated carbon component of the filter

Image: An illustration of the filter's two-stage purification, highlighting the advanced hollow fiber membrane for viral protection and activated carbon for reducing chemicals, unpleasant tastes, and odors.

การซ่อมบำรุง

Proper maintenance ensures the longevity and effectiveness of your MSR Guardian Gravity Purifier.

การแก้ไขปัญหา

ปัญหาสาเหตุที่เป็นไปได้สารละลาย
น้ำไหลช้าหรือไม่มีเลย
  • ไส้กรองอุดตัน
  • Insufficient hanging height
  • ล็อคอากาศในระบบ
  • Kinked or blocked hoses
  • Perform a filter purge using the dedicated purge hose.
  • Ensure the dirty water reservoir is hung at least 6 feet above the collection point.
  • Check all hoses for kinks or blockages.
  • Ensure the dirty water reservoir is not completely sealed if it's causing an airlock (some users report needing a partial seal).
Water Leaking from Connections
  • ข้อต่อท่อหลวม
  • โอริงหรือซีลเสียหาย
  • Damage to the dirty water reservoir
  • Tighten all hose connections securely.
  • Inspect O-rings and seals for damage; replace if necessary.
  • Inspect the dirty water reservoir for punctures or tears.
Unpleasant Taste/Odor in Purified Water
  • Activated carbon is exhausted
  • Contamination of clean water components
  • The activated carbon component has a limited life; consider replacing the filter cartridge if taste/odor persists after extensive use.
  • Ensure all clean water collection containers and hoses are clean.

ข้อมูลจำเพาะ

Dimensions of the MSR Guardian Gravity Purifier carry case

Image: The zippered carry case with dimensions of 12.5 inches in length and 4 inches in width, indicating its compact size for transport.

การรับประกันและการสนับสนุน

The MSR Guardian Gravity Purifier comes with a การรับประกันแบบจำกัดตลอดอายุการใช้งาน from Cascade Designs Inc. This warranty covers manufacturing defects in materials and workmanship for the reasonable lifetime of the product.

For warranty claims, technical support, or further inquiries, please contact MSR customer service. Refer to the official MSR website or the original product packaging for the most current contact information and detailed warranty terms.

An official Instructions for Use (IFU) document in PDF format is available for download: MSR Guardian Gravity Purifier IFU (PDF).

เอกสารที่เกี่ยวข้อง - เครื่องกรองแรงโน้มถ่วงการ์เดียน

พรีview คู่มือการใช้งาน MSR Guardian Gravity Purifier ฉบับสมบูรณ์
คู่มือโดยละเอียดสำหรับเครื่องฟอกน้ำ MSR Guardian Gravity Purifier ครอบคลุมถึงการตั้งค่า การฟอก การจัดเก็บ การฆ่าเชื้อ และการทดสอบความสมบูรณ์เพื่อน้ำดื่มที่ปลอดภัยในสภาพแวดล้อมกลางแจ้ง
พรีview คู่มือการใช้งานการ์ด SD สำหรับเครื่องบันทึกข้อมูล MSR: ฟังก์ชันการทำงานของการ์ด SD
คู่มือนี้อธิบายวิธีการใช้งานคุณสมบัติการ์ด SD กับเครื่องบันทึกข้อมูล MSR โดยครอบคลุมการบันทึกข้อมูล การเตรียมข้อมูล การอ่าน การลบ และความจุของหน่วยความจำ
พรีview คู่มือเริ่มต้นใช้งานด่วนและการติดตั้งซอฟต์แวร์เครื่องบันทึกข้อมูล MSR160
เรียนรู้วิธีการตั้งค่าและใช้งานเครื่องบันทึกข้อมูล MSR160 อย่างรวดเร็ว รวมถึงการติดตั้งซอฟต์แวร์ MSR PC การเชื่อมต่อกับ PC การเริ่มบันทึกข้อมูล และการถ่ายโอนข้อมูล พร้อมการใช้งานการ์ด SD (เป็นทางเลือก)
พรีview คู่มือผู้ใช้เครื่องบันทึกข้อมูลแรงกระแทกและการสั่นสะเทือน MSR 165
คู่มือผู้ใช้ที่ครอบคลุมสำหรับ MSR 165 Shock & Vibration Data Logger ครอบคลุมการตั้งค่า การวิเคราะห์ข้อมูล การรายงาน และฟีเจอร์ขั้นสูง เช่น FFT และการวิเคราะห์สเปกตรัม
พรีview ระบบเตาส่วนตัว MSR WindBurner: คู่มือการใช้งานและคำแนะนำด้านความปลอดภัย
คู่มือการใช้งานโดยละเอียดและคู่มือความปลอดภัยสำหรับระบบเตาเผาส่วนบุคคล MSR WindBurner เรียนรู้วิธีการตั้งค่า การใช้งาน การบำรุงรักษา และการแก้ไขปัญหา MSR ของคุณอย่างปลอดภัยampเตา ing สำหรับการผจญภัยกลางแจ้ง
พรีview คำแนะนำในการประกอบ MSR Gear Shed
คู่มือทีละขั้นตอนสำหรับการประกอบอุปกรณ์เต็นท์ MSR Gear Shed รวมถึงเนื้อหาบรรจุภัณฑ์ คำแนะนำในการตั้งค่า และเคล็ดลับการใช้งาน