Elitech LMG-10W, LMC-100A+, ILD-200

Elitech 2-Way Valve Manifold Gauge LMG-10W, Refrigerant Scale LMC-100A+, Infrared Refrigeration Leak Detector ILD-200 User Manual

Model: LMG-10W, LMC-100A+, ILD-200

การแนะนำ

This user manual provides comprehensive instructions for the Elitech HVAC/R service kit, which includes the Elitech LMG-10W 2-Way Valve Manifold Gauge, the Elitech LMC-100A+ Refrigerant Scale, and the Elitech ILD-200 Infrared Refrigeration Leak Detector. This kit is designed for professional HVAC/R technicians to perform accurate refrigerant charging, recovery, and leak detection tasks.

Elitech HVAC/R Service Kit including manifold gauge, refrigerant scale, and leak detector

Figure 1: Elitech HVAC/R Service Kit components.

ส่วนประกอบของผลิตภัณฑ์

Elitech LMG-10W 2-Way Valve Manifold Gauge

The LMG-10W is a digital manifold gauge designed for precise measurement of pressure, temperature, and vacuum in HVAC/R systems. It features a clear display and robust construction for reliable performance.

  • การควบคุมแอป: Seamless integration with the Elitech Tools App for remote monitoring and control.
  • Remote Firmware Upgrade: Allows for convenient updates to the device's software.
  • Accurate Tightness Test Results: Provides precise data for system integrity checks.
  • Instant Report Export: Generate and export reports for documentation.
  • Automatic Calculation: Calculates subcooling and superheat automatically.
  • อายุการใช้งานแบตเตอรี่ยาวนาน: Up to 200+ hours of operation.
  • ช่วงการวัด: -14.5 to 800 psi.
  • ความแม่นยำ: ±0.5% FS.
  • หน่วย: psi, kg/cm3, kPa, MPa, bar.
  • ช่วงอุณหภูมิการทำงาน: 14~122°F / -10~50°C.
Elitech LMG-10W digital manifold gauge with hoses and temperature clamps

Figure 2: Elitech LMG-10W Digital Manifold Gauge with included accessories.

Elitech LMG-10W digital manifold gauge display showing various data points and features like APP control and remote firmware upgrade

Figure 3: Key features and display of the Elitech LMG-10W.

Elitech LMG-10W digital manifold gauge dimensions and specifications

Figure 4: Dimensions and detailed specifications of the Elitech LMG-10W.

Elitech LMC-100A+ Refrigerant Scale

The LMC-100A+ is a high-capacity electronic refrigerant charging and recovery scale, essential for accurate refrigerant handling.

  • ความจุ: Up to 220lbs (100kg).
  • ความแม่นยำ: ±0.05% readings +10g.
  • หน่วย: Kg/Lb/Oz.
  • อายุการใช้งานแบตเตอรี่ยาวนาน: นานถึง 40 ชั่วโมง
  • ปิดอัตโนมัติ: After 10 minutes of inactivity to conserve battery.
Elitech LMC-100A+ refrigerant scale in its protective case

Figure 5: Elitech LMC-100A+ Refrigerant Scale within its carrying case.

Elitech LMC-100A+ refrigerant scale showing battery life and auto shut-off features

Figure 6: Battery life and auto shut-off features of the Elitech LMC-100A+.

Elitech ILD-200 Infrared Refrigeration Leak Detector

The ILD-200 is an advanced infrared leak detector designed to quickly and accurately pinpoint refrigerant leaks in HVAC/R systems.

  • Detects All Halogenated Gases: Including CFCs, HFCs, HCFCs, HCs, HFOs, and mixed refrigerants (e.g., R11, R22, R404a, R410a, R600a, R1234yf, AZ-50, HP62, MP39).
  • Anti-interference & High Precision: Ensures reliable detection in various environments.
  • NDIR Sensor: Provides longer sensor life.
  • ตอบกลับทันที: Quick detection of leaks.
  • การปฏิบัติตามมาตรฐาน: Meets SAE-2791 and SAE-2913 standards.
  • ความไวสูงสุด: 0.1oz/yr.
  • แบตเตอรี่: 3.7V 3000mAh.
  • ใบรับรอง CE: ได้รับการรับรองด้านความปลอดภัยและคุณภาพแล้ว
Elitech ILD-200 infrared refrigerant leak detector

Figure 7: Elitech ILD-200 Infrared Refrigerant Leak Detector.

Elitech ILD-200 infrared refrigerant leak detector showing features like anti-interference and NDIR sensor

Figure 8: Key features of the Elitech ILD-200.

Elitech ILD-200 infrared refrigerant leak detector dimensions and specifications

Figure 9: Dimensions and detailed specifications of the Elitech ILD-200.

การตั้งค่า

Before operating the Elitech HVAC/R service kit, ensure all components are properly set up and charged.

  1. การแกะกล่อง: Carefully remove all items from the packaging. Verify that all components listed in the packing list are present and undamaged.
  2. การติดตั้ง/ชาร์จแบตเตอรี่:
    • LMG-10W: Ensure the manifold gauge is charged or has sufficient battery life. Refer to the individual LMG-10W manual for specific battery type and charging instructions.
    • LMC-100A+: Install batteries as per the scale's instructions.
    • ILD-200: Charge the leak detector using the provided charger until the battery indicator shows full.
  3. การติดตั้งแอปพลิเคชัน (ไม่บังคับ แต่แนะนำให้ทำ): Download the "Elitech Tools" app from your device's app store (iOS and Android). This app allows for integrated management of Elitech tools.
  4. Initial Calibration/Zeroing:
    • LMG-10W: Power on the manifold gauge. Perform a zero calibration as instructed in its specific manual to ensure accurate pressure readings.
    • LMC-100A+: Place the scale on a flat, stable surface. Power it on and press the "Z/T" button to zero the scale before placing any refrigerant cylinders on it.
    • ILD-200: Allow the leak detector to warm up as per its instructions. Ensure it is in a clean air environment when powered on to establish a baseline.
  5. Hose Connection (LMG-10W): Connect the appropriate refrigerant hoses to the LMG-10W manifold gauge and to the HVAC/R system service ports as required for your specific task (e.g., charging, recovery, evacuation).

คำแนะนำการใช้งาน

This section provides general operating guidelines for using the Elitech HVAC/R service kit. Always refer to the specific manuals for each device for detailed operational procedures.

Refrigerant Charging/Recovery (Using LMG-10W and LMC-100A+)

  1. เชื่อมต่อท่อ: Connect the LMG-10W to the HVAC/R system's high and low-pressure service ports using the appropriate hoses. Connect the center hose to the refrigerant cylinder or recovery machine.
  2. Place Cylinder on Scale: Place the refrigerant cylinder on the LMC-100A+ scale. Ensure the scale is zeroed before placing the cylinder.
  3. ตรวจสอบการอ่าน: Use the LMG-10W to monitor system pressures and temperatures. The LMC-100A+ will display the refrigerant weight.
  4. Charge/Recover: Open the manifold valves as required for charging or recovery. Monitor the LMC-100A+ to ensure the correct amount of refrigerant is transferred.
  5. การตัดการเชื่อมต่อ: Once the process is complete, close all valves and carefully disconnect the hoses.

Leak Detection (Using ILD-200)

  1. เปิดเครื่อง: Turn on the ILD-200 leak detector. Allow it to warm up and self-calibrate in a clean air environment.
  2. ปรับความไว: Adjust the sensitivity setting (Low, Medium, High) based on the suspected leak size and environment. Start with a higher sensitivity for general scanning.
  3. Scan System: Slowly move the probe tip around suspected leak areas (e.g., joints, fittings, valves, coils). The detector will alarm and indicate the presence of refrigerant.
  4. Pinpoint Leak: Once a leak is detected, move the probe slowly back and forth to pinpoint the exact source. The alarm intensity will typically increase as you get closer to the leak.
  5. ตรวจสอบ: After identifying a leak, ventilate the area and re-scan to confirm the leak location.

การซ่อมบำรุง

Proper maintenance ensures the longevity and accuracy of your Elitech HVAC/R service kit.

การแก้ไขปัญหา

This section addresses common issues you might encounter with your Elitech HVAC/R service kit.

ปัญหาสาเหตุที่เป็นไปได้สารละลาย
LMG-10W: การอ่านค่าแรงดันไม่แม่นยำNeeds zero calibration; sensor contamination; faulty hose connection.Perform zero calibration. Clean sensor if accessible. Check hose connections for leaks or blockages.
LMG-10W: จอภาพไม่เปิดLow battery; power button issue.Charge the device. Press and hold the power button firmly.
LMC-100A+: การอ่านค่าน้ำหนักไม่แม่นยำScale not zeroed; unstable surface; battery low.Zero the scale before use. Place on a flat, stable surface. Replace batteries.
LMC-100A+: สเกลไม่เปิดแบตเตอรี่หมด, ติดตั้งแบตเตอรี่ไม่ถูกต้องเปลี่ยนแบตเตอรี่ ตรวจสอบให้แน่ใจว่าใส่แบตเตอรี่โดยให้ขั้วถูกต้อง
ILD-200: No leak detection/false alarms.Sensor contaminated; low sensitivity setting; strong air currents.Clean sensor tip. Increase sensitivity. Shield the area from drafts.
ILD-200: เครื่องเปิดไม่ติดBattery depleted; power button issue.Charge the device fully. Press and hold the power button.

ข้อมูลจำเพาะ

Detailed specifications for each component of the Elitech HVAC/R service kit.

Elitech LMG-10W 2-Way Valve Manifold Gauge

Elitech LMC-100A+ Refrigerant Scale

Elitech ILD-200 Infrared Refrigeration Leak Detector

การรับประกันและการสนับสนุน

Elitech provides dedicated customer support for its products.

For technical questions, troubleshooting assistance, or warranty inquiries, please contact Elitech's US-based customer service team. They are available 24/7 via email or phone.

Refer to the Elitech official webไซต์หรือบรรจุภัณฑ์ผลิตภัณฑ์เพื่อให้มีข้อมูลติดต่อล่าสุด

เอกสารที่เกี่ยวข้อง - LMG-10W, LMC-100A+, ILD-200

พรีview คู่มือการใช้งานเครื่องตรวจจับการรั่วไหลของสารทำความเย็นแบบอินฟราเรด Elitech ILD Series
คู่มือการใช้งานฉบับสมบูรณ์สำหรับเครื่องตรวจจับการรั่วไหลของสารทำความเย็นแบบอินฟราเรดซีรีส์ Elitech ILD (ILD-100, ILD-200, ILD-300) ครอบคลุมข้อมูลจำเพาะ การใช้งาน การบำรุงรักษา และคุณสมบัติ เรียนรู้วิธีการตรวจจับการรั่วไหลของสารทำความเย็นอย่างมีประสิทธิภาพด้วยอุปกรณ์ขั้นสูงนี้
พรีview คู่มือการใช้งานเครื่องตรวจจับการรั่วไหลแบบอินฟราเรด Elitech ILD-100/ILD-200/ILD-300
คู่มือการใช้งานสำหรับเครื่องตรวจจับการรั่วไหลของสารทำความเย็นแบบอินฟราเรด Elitech ซีรีส์ ILD (ILD-100, ILD-200, ILD-300) ให้ข้อมูลโดยละเอียดเกี่ยวกับการใช้งาน ข้อมูลจำเพาะ คุณสมบัติ และการบำรุงรักษา เพื่อการตรวจจับการรั่วไหลของสารทำความเย็นที่แม่นยำ
พรีview คู่มือผู้ใช้เกจวัดแรงดันดิจิทัลอัจฉริยะ Elitech MS-100 PLUS
คู่มือการใช้งานฉบับสมบูรณ์สำหรับเกจวัดแรงดันดิจิทัลอัจฉริยะ Elitech MS-100 PLUS ครอบคลุมถึงการแนะนำผลิตภัณฑ์ คำแนะนำด้านความปลอดภัย และอื่นๆviewรวมถึงฟังก์ชั่นของปุ่ม พารามิเตอร์ทางเทคนิค และคู่มือการใช้งานฉบับย่อสำหรับระบบทำความเย็นและระบบปรับอากาศ
พรีview คู่มือผู้ใช้เครื่องตรวจจับการรั่วไหลของไดโอดอินฟราเรดและความร้อน Elitech IR-200
คู่มือผู้ใช้ฉบับสมบูรณ์สำหรับ Elitech IR-200 เครื่องตรวจจับการรั่วไหลแบบเซ็นเซอร์คู่ที่ใช้เทคโนโลยีอินฟราเรดและไดโอดความร้อน เรียนรู้เกี่ยวกับข้อมูลจำเพาะ การใช้งาน การบำรุงรักษา และคุณสมบัติต่างๆ สำหรับการตรวจจับการรั่วไหลของสารทำความเย็น
พรีview คู่มือการใช้งานเครื่องตรวจจับโคโรนา Elitech WJL-6000S
คู่มือผู้ใช้สำหรับเครื่องตรวจจับโคโรนา Elitech WJL-6000S ซึ่งให้คำแนะนำโดยละเอียดเกี่ยวกับการใช้งาน การตรวจจับ การแก้ไขปัญหา และการบำรุงรักษาสำหรับการตรวจจับการรั่วไหลของสารทำความเย็นในระบบต่างๆ
พรีview คู่มือผู้ใช้เกจวัดแรงดันแบบดิจิทัล Elitech MS Series
คู่มือการใช้งานเกจวัดแรงดันดิจิทัล Elitech MS Series ครอบคลุมรายละเอียดผลิตภัณฑ์และภาพรวมทั่วไปviewรวมถึงฟังก์ชั่นของปุ่ม ข้อมูลจำเพาะ คู่มือเริ่มต้นใช้งานอย่างรวดเร็ว ขั้นตอนการใช้งาน แอปพลิเคชันอัจฉริยะ และการบำรุงรักษา