X-Sense SD19-W, XC01-WR, RC01

X-Sense Wireless Interconnected Safety System User Manual

Models: SD19-W Smoke Detector, XC01-WR Carbon Monoxide Alarm, RC01 Remote Controller

1. บทนำ

This manual provides essential information for the proper installation, operation, and maintenance of your X-Sense Wireless Interconnected Safety System. This system includes the SD19-W smoke detector, XC01-WR carbon monoxide alarms, and the RC01 remote controller. Please read this manual thoroughly before installation and keep it for future reference.

2. เนื้อหาบรรจุภัณฑ์

The X-Sense Wireless Interconnected Safety System bundle includes the following components:

  • 1 x SD19-W Wireless Interconnected Smoke Detector
  • 2 x XC01-WR Wireless Interconnected Carbon Monoxide Alarms
  • 1 x RC01 Remote Controller
  • Mounting brackets and screws for each alarm
  • คู่มือการใช้งาน (เอกสารนี้)
Image showing one X-Sense SD19-W smoke detector, two X-Sense XC01-WR carbon monoxide alarms, and one X-Sense RC01 remote controller.

รูปที่ 1: Components of the X-Sense Wireless Interconnected Safety System. This image displays the SD19-W smoke detector (top right), two XC01-WR carbon monoxide alarms (bottom), and the RC01 remote controller (left).

3. สินค้าหมดview

3.1 SD19-W Wireless Interconnected Smoke Detector

The SD19-W is a wireless interconnected smoke detector designed to provide early warning of fire. Its housing is constructed from flame-retardant and high-temperature resistant ABS material for enhanced safety and durability.

3.2 XC01-WR Wireless Interconnected Carbon Monoxide Alarm

The XC01-WR is a wireless interconnected carbon monoxide (CO) alarm. It features a high-quality Figaro electrochemical CO sensor, known for its stable performance and a 10-year lifespan. The alarm is powered by a replaceable battery that lasts for 5 years.

3.3 RC01 Remote Controller

The RC01 remote controller provides a convenient way to interact with your interconnected alarms. It allows you to easily test all linked alarms and mute false alarms without needing to physically reach each unit, which is particularly useful for alarms installed in high locations or for users with mobility challenges.

4. การตั้งค่าและการติดตั้ง

4.1 แนวทางการจัดวางทั่วไป

For optimal protection, install smoke alarms on every level of your home, inside each sleeping area, and in the hallway outside each sleeping area. Install carbon monoxide alarms on every level of your home and in sleeping areas. Avoid installing alarms near windows, doors, or vents where drafts could interfere with sensor readings. Keep alarms away from areas with high humidity or extreme temperatures.

4.2 SD19-W Smoke Alarm Installation

  1. Choose a suitable location on the ceiling or wall, away from corners and obstructions.
  2. ติดตั้งวงเล็บโดยใช้สกรูที่ให้มา
  3. Attach the smoke alarm to the mounting bracket by twisting it clockwise until it clicks into place.
  4. Perform an initial test by pressing the 'TEST' button.

4.3 XC01-WR Carbon Monoxide Alarm Installation

  1. Select a location that is at least 5 feet (1.5 meters) from the floor, but not on the ceiling unless specified by local codes.
  2. ติดตั้งวงเล็บโดยใช้สกรูที่ให้มา
  3. Attach the CO alarm to the mounting bracket by twisting it clockwise until it clicks into place.
  4. Perform an initial test by pressing the 'TEST' button.

4.4 Wireless Interconnection Process

The X-Sense Link+ system allows up to 24 wireless alarms (smoke, CO, and combination alarms) to be interconnected via RF technology, creating a comprehensive safety network. Follow the instructions provided with each alarm to initiate the interconnection process. Typically, one alarm is set as the primary unit, and others are paired to it. Once interconnected, if one alarm detects a hazard, all linked alarms will sound.

4.5 RC01 Remote Controller Pairing

To pair the RC01 remote controller with your interconnected alarms, follow the specific pairing instructions included with the remote. This usually involves activating a pairing mode on the alarms and then on the remote controller within a short timeframe. Once paired, the remote can control all linked alarms.

5. การดำเนินการ

5.1 Testing the Alarms

It is recommended to test your alarms weekly to ensure proper operation. Press and hold the 'TEST' button on any alarm or use the RC01 remote controller. All interconnected alarms should sound a loud alarm and flash their LED indicators. Release the button to stop the test.

5.2 Silencing Alarms

In case of a false alarm (e.g., from cooking fumes), you can silence the alarms by pressing the 'TEST/SILENCE' button on any alarm or by using the mute function on the RC01 remote controller. The alarm will temporarily silence for a set period, typically 9 minutes, before resetting. If the hazard persists, the alarm will reactivate.

5.3 LED Indicators and Audible Signals

Your X-Sense alarms use both LED indicators and audible signals to communicate their status:

  • ไฟ LED สีเขียว: Indicates normal operation and power.
  • ไฟ LED สีแดง: Flashes during an alarm event (smoke or CO detected) or during a test.
  • ไฟ LED สีเหลือง: Indicates a fault, low battery, or end-of-life warning.
  • เสียงปลุก: A loud, piercing sound indicates a detected hazard. Different patterns may distinguish between smoke and CO alarms.

5.4 ฟังก์ชันของรีโมทคอนโทรล

The RC01 remote controller allows you to:

  • ทดสอบ: Initiate a test of all interconnected alarms.
  • ปิดเสียง: Silence false alarms across the interconnected system.

6. การบำรุงรักษา

6.1 Battery Replacement (XC01-WR)

The XC01-WR carbon monoxide alarm uses a replaceable battery with a 5-year lifespan. When the battery is low, the alarm will chirp and the yellow LED will flash. Refer to the specific instructions provided with the XC01-WR for safe battery replacement.

6.2 การทำความสะอาด

Clean your alarms regularly, at least once a month, to prevent dust and debris from accumulating and affecting sensor performance. Use a soft, damp cloth to wipe the exterior. Do not use cleaning solvents or spray directly onto the alarm. Vacuum around the vents with a soft brush attachment.

6.3 การทดสอบเป็นประจำ

Continue to test your alarms weekly as described in Section 5.1 to ensure they are functioning correctly.

7 การแก้ไขปัญหา

If your alarm is not functioning as expected, refer to the following common issues and solutions:

  • Alarm chirps periodically: This usually indicates a low battery (for XC01-WR) or an end-of-life warning. Replace the battery or the unit as required.
  • Alarm sounds without apparent hazard: This could be a false alarm due to cooking fumes, steam, or dust. Use the silence feature. If it persists, clean the alarm.
  • Alarm fails to test: Ensure the battery is correctly installed and charged. If the issue persists, the unit may be faulty and require replacement.
  • Alarms not interconnecting: Re-attempt the interconnection process, ensuring all alarms are within range and in pairing mode.

For persistent issues, contact X-Sense customer support.

8. ข้อมูลจำเพาะ

คุณสมบัติข้อมูลจำเพาะ
ยี่ห้อเอ็กซ์เซนส์
Model (Smoke Alarm)SD19-ว
Model (CO Alarm)XC01-WR
รุ่น (รีโมทคอนโทรล)RC01
แหล่งพลังงานใช้พลังงานจากแบตเตอรี่
ประเภทสัญญาณเตือนสามารถได้ยินเสียง
ประเภทเซ็นเซอร์ COFigaro Electrochemical
CO Alarm Battery Life5 years (replaceable)
CO Sensor Lifespan10 ปี
การเชื่อมโยงWireless (RF technology), up to 24 X-Sense Link+ alarms

9. การรับประกันและการสนับสนุน

X-Sense products typically come with a limited warranty. Please refer to the warranty card included with your product for specific terms and conditions, including the warranty period and coverage details. For technical support, troubleshooting assistance, or to inquire about warranty claims, please visit the official X-Sense website or contact their customer service department directly. Contact information is usually available on the product packaging or the X-Sense brand store.

เอกสารที่เกี่ยวข้อง - SD19-W, XC01-WR, RC01

พรีview คู่มือการใช้งานเครื่องตรวจจับก๊าซคาร์บอนมอนอกไซด์แบบไร้สาย X-Sense XC01-WR
คู่มือการใช้งานสำหรับเครื่องตรวจจับก๊าซคาร์บอนมอนอกไซด์แบบไร้สาย X-Sense XC01-WR ให้ข้อมูลโดยละเอียดเกี่ยวกับการติดตั้ง การใช้งาน คุณสมบัติ การเชื่อมต่อ การทดสอบ การบำรุงรักษา การแก้ไขปัญหา และแนวทางด้านความปลอดภัยสำหรับการใช้งานในครัวเรือน
พรีview แคตตาล็อกผลิตภัณฑ์เพื่อความปลอดภัยภายในบ้าน X-Sense | เครื่องตรวจจับควัน, เครื่องตรวจจับ CO, ระบบรักษาความปลอดภัยอัจฉริยะ
สำรวจโซลูชันความปลอดภัยภายในบ้าน X-Sense ที่ครอบคลุม ครอบคลุมตั้งแต่เครื่องตรวจจับควันขั้นสูง เครื่องตรวจจับก๊าซคาร์บอนมอนอกไซด์ สัญญาณกันขโมยแบบรวม และระบบรักษาความปลอดภัยบ้านอัจฉริยะ เรียนรู้เกี่ยวกับคุณสมบัติ ข้อมูลจำเพาะ และเทคโนโลยีที่เป็นนวัตกรรม
พรีview คู่มือผู้ใช้เครื่องแจ้งเตือนควันไร้สาย X-Sense XS01-WR
คู่มือผู้ใช้นี้ให้คำแนะนำอย่างละเอียดเกี่ยวกับเครื่องตรวจจับควันแบบไร้สาย X-Sense XS01-WR ครอบคลุมถึงความปลอดภัย การตั้งค่า การเชื่อมต่อ การติดตั้ง การบำรุงรักษา และการแก้ไขปัญหา เพื่อความปลอดภัยจากอัคคีภัยที่ดีที่สุด
พรีview คู่มือการใช้งานเครื่องตรวจจับควันแบบไร้สายเชื่อมต่อกัน X-Sense รุ่น SD19-W และ SD20-W
คู่มือการใช้งานอย่างเป็นทางการสำหรับเครื่องตรวจจับควันแบบไร้สายเชื่อมต่อกันรุ่น X-Sense SD19-W และ SD20-W ซึ่งให้ข้อมูลเกี่ยวกับคุณสมบัติ การติดตั้ง และการใช้งาน รวมถึงรายละเอียดการติดต่อของผู้ผลิต
พรีview คู่มือการใช้งานเครื่องตรวจจับควันและก๊าซคาร์บอนมอนอกไซด์แบบไร้สาย X-Sense XP01-W
คู่มือการใช้งานฉบับสมบูรณ์สำหรับเครื่องตรวจจับควันและก๊าซคาร์บอนมอนอกไซด์แบบไร้สาย X-Sense XP01-W ครอบคลุมการติดตั้ง การใช้งาน การบำรุงรักษา และความปลอดภัย
พรีview คู่มือผู้ใช้เครื่องตรวจจับควันและก๊าซคาร์บอนมอนอกไซด์แบบไร้สาย X-Sense (SC06-W/SC07-W)
คู่มือการใช้งานฉบับสมบูรณ์สำหรับเครื่องตรวจจับควันและก๊าซคาร์บอนมอนอกไซด์แบบไร้สายเชื่อมต่อกัน X-Sense รุ่น SC06-W และ SC07-W ครอบคลุมการติดตั้ง การใช้งาน คุณสมบัติด้านความปลอดภัย การเชื่อมต่อ และการแก้ไขปัญหา เพื่อการปกป้องบ้านอย่างน่าเชื่อถือ