1. บทนำ
This user manual provides comprehensive instructions for the safe and effective operation of the Rigol DG1062Z Function/Arbitrary Waveform Generator. The DG1062Z is a high-performance, multi-functional signal source capable of generating various waveforms, including sine, square, ramp, pulse, noise, and arbitrary waveforms, with a maximum frequency of 60MHz across two independent channels. It features a 14-bit vertical resolution and 8Mpts arbitrary wave length, making it suitable for a wide range of applications in electronics testing, education, and research.
Please read this manual thoroughly before operating the device to ensure proper usage and to prevent damage to the instrument or injury to personnel. Keep this manual for future reference.

รูปที่ 1.1 : ด้านหน้า view of the Rigol DG1062Z Function/Arbitrary Waveform Generator, showing the display, control buttons, and output connectors.
2. การตั้งค่าและการติดตั้ง
2.1 การแกะกล่องและการตรวจสอบเบื้องต้น
Carefully remove the DG1062Z from its packaging. Inspect the instrument for any signs of damage that may have occurred during transit. If any damage is found, contact your Rigol distributor immediately.

Figure 2.1: The Rigol DG1062Z Function/Arbitrary Waveform Generator along with its standard accessories, including power cords and BNC cables.
2.2 การเชื่อมต่อสายไฟ
- ตรวจสอบให้แน่ใจว่าสวิตช์เปิด/ปิดที่แผงด้านหน้าอยู่ในตำแหน่งเปิด ปิด ตำแหน่ง.
- Connect the supplied AC power cord to the power input connector on the rear panel of the instrument.
- Plug the other end of the power cord into a grounded AC power outlet. The DG1062Z supports AC 100-240V, 45-440Hz.
2.3 การเชื่อมต่อกับอุปกรณ์อื่นๆ
The DG1062Z offers various connectivity options for integration into your test setup.
- ช่องสัญญาณเอาต์พุต (CH1, CH2): Use BNC cables to connect the CH1 and CH2 output connectors on the front panel to your device under test or an oscilloscope.
- USB Host/Device: The front panel USB host port allows for connecting USB storage devices. The rear panel USB device port can be used for PC communication.
- LAN (LXI): The Ethernet port on the rear panel enables network connectivity for remote control and data transfer.
- External Reference Input/Output (10MHz In/Out): For synchronization with external reference clocks.
- External Modulation/Trigger Inputs: For external control of modulation and burst functions.

Figure 2.2: Rear panel of the Rigol DG1062Z, highlighting the power input, LAN, USB device, and external reference/trigger ports.
2.4 การเปิดเครื่องครั้งแรก
After connecting the power cord, press the power switch on the front panel to turn on the instrument. The display will illuminate, and the system will perform a self-test. Once the boot sequence is complete, the main interface will appear, ready for operation.
3. คู่มือการใช้งาน
3.1 โอเวอร์แผงด้านหน้าview
The front panel of the DG1062Z is designed for intuitive operation. It includes a color LCD display, waveform selection buttons, numeric keypad, navigation keys, and output connectors.

รูปที่ 3.1: มุม view of the DG1062Z, providing a clear perspective of the display and the arrangement of control buttons.
3.2 Generating Standard Waveforms
To generate a standard waveform:
- Press one of the waveform buttons (e.g., ไซน์, สี่เหลี่ยม, Ramp, ชีพจร, เสียงรบกวน, อาร์บ) to select the desired waveform type.
- Use the numeric keypad and navigation keys to set parameters such as ความถี่, Ampความสูง (Vpp), ออฟเซ็ต, และ เฟส.
- กดปุ่ม เอาท์พุต button for the desired channel (CH1 or CH2) to enable the waveform output. The button will illuminate when the output is active.
3.3 Modulation Functions
The DG1062Z supports various modulation types. Press the ม็อด button to access modulation settings.
- เช้า (Ampการมอดูเลชั่นความ ليحظة (Litude Modulation): Adjust carrier frequency, modulation depth, and modulating waveform.
- FM (การปรับความถี่): Set carrier frequency, frequency deviation, and modulating waveform.
- PM (Phase Modulation): Configure carrier frequency, phase deviation, and modulating waveform.
- ถาม (Amplitude Shift Keying): Define carrier frequency and keying rate.
- FSK (Frequency Shift Keying): Specify carrier frequency and keying rate.
3.4 Sweep and Burst Modes
The instrument can generate swept and burst waveforms.
- กวาด: กด กวาด to configure start/stop frequency, sweep time, and sweep type (linear/log).
- ระเบิด: กด ระเบิด to set the number of cycles, burst period, and trigger source (internal/external/manual).
3.5 Using the Counter Function
The DG1062Z includes a built-in frequency counter. Press the เคาน์เตอร์ button to activate and configure the counter. It can measure frequency, period, and duty cycle of external signals.
3.6 การบันทึกและการเรียกคืนการตั้งค่า
To save current instrument settings, press the เก็บ button. To recall previously saved settings, press the การเรียกคืน button (often accessed via Utility menu or dedicated button).
4. การบำรุงรักษา
4.1 การทำความสะอาดเครื่องมือ
To maintain the appearance and prolong the life of the instrument, clean the exterior surfaces regularly. Use a soft cloth dampened with a mild detergent or water. Do not use abrasive cleaners or solvents that may damage the plastic parts.
4.2 การสอบเทียบ
The DG1062Z is factory calibrated. For optimal performance, periodic calibration by qualified service personnel is recommended. Refer to Rigol's official support channels for calibration services.
4.3 พื้นที่จัดเก็บ
When not in use for extended periods, store the instrument in a clean, dry environment, away from direct sunlight and extreme temperatures. Ensure all cables are disconnected and the power is off.
5 การแก้ไขปัญหา
| ปัญหา | สาเหตุที่เป็นไปได้ | สารละลาย |
|---|---|---|
| เครื่องไม่เปิดใช้งาน | Power cord not connected properly; Power outlet faulty; Internal fuse blown. | ตรวจสอบการเชื่อมต่อสายไฟ; ทดสอบเต้ารับไฟฟ้า; ติดต่อฝ่ายบริการเพื่อเปลี่ยนฟิวส์ |
| ไม่มีสัญญาณรูปคลื่นส่งออก | Output channel not enabled; Amplitude set to zero; Cable connection faulty. | กดปุ่ม เอาท์พุต button for the channel; Increase amplitude setting; Check BNC cable connections. |
| Incorrect waveform displayed on oscilloscope. | Incorrect settings on DG1062Z; Oscilloscope settings incorrect (e.g., vertical scale, time base). | Verify waveform parameters on DG1062Z; Adjust oscilloscope settings to match expected signal. |
| รีโมทคอนโทรลไม่ทำงาน | Incorrect LAN/USB settings; Driver issues; Network connectivity problems. | Check network cable and IP settings; Install correct USB drivers; Verify network connection. |
6. ข้อมูลจำเพาะ
The following table lists the key specifications for the Rigol DG1062Z Function/Arbitrary Waveform Generator.
| พารามิเตอร์ | ค่า |
|---|---|
| ขนาดสินค้า | 10.3 x 12.54 x 4.41 นิ้ว; 7.05 ปอนด์ |
| หมายเลขรุ่นสินค้า | DG1062Z |
| ผู้ผลิต | ริโกล |
| ประเภทการติดตั้ง | การติดตั้งบนพื้นผิว |
| จำนวนช่องสัญญาณ | 2 |
| ความถี่สูงสุด | 60เมกะเฮิรตซ์ |
| ความละเอียดแนวตั้ง | 14 บิต |
| Arbitrary Wave Length | 8Mpt |
7. การรับประกันและการสนับสนุน
7.1 ข้อมูลการรับประกัน
Rigol products are typically covered by a manufacturer's warranty against defects in materials and workmanship. For specific warranty terms and duration, please refer to the warranty card included with your product or visit the official Rigol webไซต์ โปรดเก็บใบเสร็จรับเงินไว้เป็นหลักฐานการซื้อสำหรับการเรียกร้องการรับประกัน
7.2 การสนับสนุนด้านเทคนิค
For technical assistance, troubleshooting, or service inquiries, please contact Rigol customer support. You can find contact information, FAQs, and additional resources on the official Rigol webเว็บไซต์:
Visit Rigol Support Webเว็บไซต์
When contacting support, please have your instrument's model number (DG1062Z) and serial number ready.