QIACHIP KR2202

คู่มือการใช้งานสวิตช์รีเลย์ควบคุมระยะไกลไร้สาย RF 2 ช่องสัญญาณ 433MHz รุ่น QIACHIP KR2202

Brand: QIACHIP | Model: KR2202

1. บทนำ

This manual provides detailed instructions for the installation, operation, and maintenance of the QIACHIP KR2202 2-Channel 433MHz Wireless RF Remote Control Relay Switch. This universal switch is designed for controlling various electrical devices such as garage door openers, LED lights, and motors, offering flexible functionality with adjustable working modes.

2. ข้อมูลด้านความปลอดภัย

3. เนื้อหาบรรจุภัณฑ์

QIACHIP KR2202 receiver module, protective case, and four remote controls

Image: QIACHIP KR2202 receiver module, protective case, and four remote controls.

4. ข้อมูลจำเพาะผลิตภัณฑ์

ข้อมูลจำเพาะค่า
ยี่ห้อเฉียชิป
แบบอย่างKR2202
อินพุต Voltageไฟฟ้ากระแสสลับ 85~220 โวลต์
ความถี่433เมกะเฮิรตซ์
ช่องทางการ2 ช่อง
Max Remote Controllers20
ระยะการส่งข้อมูลUp to 164ft/50m (no obstacle)
คะแนนรีเลย์10A (each relay)
ประเภทการติดตั้งราง DIN

5. การติดตั้งและการเดินสายไฟ

The KR2202 receiver module supports various wiring configurations for different applications. Always ensure power is disconnected before making any wiring changes.

5.1 General Connection Modes

Diagrams illustrating various circuit connection modes for the QIACHIP KR2202, including AC power, DC power, and different load types.

Image: Diagrams illustrating various circuit connection modes for the QIACHIP KR2202, including AC power, DC power, and different load types.

This diagram shows common wiring setups for AC and DC loads. Pay close attention to the Live (L) and Neutral (N) connections for AC power, and Positive (+) and Negative (-) for DC power. The relay outputs provide Normally Open (NO), Common (COM), and Normally Closed (NC) contacts for flexible control.

5.2 Wiring Diagram for Motors

Wiring diagram for connecting the KR2202 to a DC motor for forward and reverse rotation using AC 85-220V input.

Image: Wiring diagram for connecting the KR2202 to a DC motor for forward and reverse rotation using AC 85-220V input.

For controlling a DC motor with forward and reverse rotation, connect the AC 85-220V input to the 'IN' terminals. The DC motor's two wires are connected to terminals 5 and 2. The positive pole of the external DC power supply connects to terminals 6 and 3, and the negative pole connects to terminals 1 and 4. The live wire of the 220V AC power supply connects to the L interface, and the neutral wire to the N interface, powering the controller.

5.3 Wiring Diagram for Lights

Wiring diagram for connecting the KR2202 to DC lamps using AC 85-220V input.

Image: Wiring diagram for connecting the KR2202 to DC lamps using AC 85-220V input.

To control two DC lamps, connect the positive poles of the lamps to terminals 6 and 3 respectively. The negative poles of the lamps connect to the negative pole of the external DC power supply. The positive pole of the external DC power supply connects to interfaces 5 and 2 respectively. The live wire of the AC power supply connects to the L interface, and the neutral wire connects to the N interface.

6. Remote Control Pairing and Operation

The KR2202 receiver supports Momentary, Toggle, and Latched modes. Follow these steps to pair your remote controls and set the desired operating mode.

6.1 การล้างรหัสที่มีอยู่

  1. Press the 'Learning Button' on the receiver module 8 times.
  2. The indicator light will flash and then go out, indicating that all previously paired remote controls have been cleared.

6.2 Momentary Mode Pairing

In Momentary mode, the relay activates only while the remote button is pressed and deactivates upon release.

  1. Press the 'Learning Button' on the receiver module 1 time. The indicator light will turn on.
  2. Press the first button (e.g., 'A') on your remote control. The indicator light will flash and then go out.
  3. Press the second button (e.g., 'B') on your remote control. The indicator light will flash and then go out.
  4. Pairing is successful. Now, pressing 'A' will activate one relay, and pressing 'B' will activate the other, as long as the button is held down.

6.3 Toggle Mode Pairing

In Toggle mode, pressing a button once activates the relay, and pressing the same button again deactivates it.

  1. Press the 'Learning Button' on the receiver module 2 times. The indicator light will turn on.
  2. Press the first button (e.g., 'A') on your remote control. The indicator light will flash and then go out.
  3. Press the second button (e.g., 'B') on your remote control. The indicator light will flash and then go out.
  4. Pairing is successful. Press 'A' to turn on/off the first relay, and 'B' to turn on/off the second relay.

6.4 Latched Mode Pairing

In Latched mode, pressing one button activates a relay, and pressing another button deactivates it. This mode typically requires a remote with at least two distinct buttons for each channel (e.g., 'A' for ON, 'B' for OFF).

  1. Press the 'Learning Button' on the receiver module 3 times. The indicator light will turn on.
  2. Press the first button (e.g., 'A') on your remote control. The indicator light will flash and then go out.
  3. Press the second button (e.g., 'B') on your remote control. The indicator light will flash and then go out.
  4. Pairing is successful. Press 'A' to activate the first relay, and 'B' to deactivate it.

Important Note for Latched Mode:

Diagrams illustrating the steps for pairing remote controls in Momentary, Toggle, and Latched modes with the QIACHIP KR2202 receiver.

Image: Diagrams illustrating the steps for pairing remote controls in Momentary, Toggle, and Latched modes with the QIACHIP KR2202 receiver.

7. การสมัคร

The QIACHIP KR2202 is versatile and can be used in a wide range of applications, from simple domestic remote control to autonomous control systems.

Illustrations of various applications for the QIACHIP KR2202, including motor control, shutter doors, home appliances, electric gates, workshop management, and DC lighting.

Image: Illustrations of various applications for the QIACHIP KR2202, including motor control, shutter doors, home appliances, electric gates, workshop management, and DC lighting.

8. การบำรุงรักษา

9 การแก้ไขปัญหา

10. การรับประกันและการสนับสนุน

QIACHIP products are designed for reliability and performance. For any issues or technical support, please contact QIACHIP customer service. Keep your purchase receipt for warranty claims. The manufacturer is QIACHIP.

เอกสารที่เกี่ยวข้อง - KR2202

พรีview คู่มือการติดตั้งและการใช้งานเครื่องรับสัญญาณ QIACHIP KR1201A/KR1201B 12V 1 ช่องสัญญาณ
คู่มือฉบับสมบูรณ์สำหรับโมดูลรับสัญญาณรีเลย์ RF 1 ช่องสัญญาณ 12V รุ่น QIACHIP KR1201A และ KR1201B เรียนรู้เกี่ยวกับแผนผังการต่อสาย โหมดการทำงาน (ชั่วขณะ, สลับ, ล็อค, หน่วงเวลา) และขั้นตอนการตั้งค่าสำหรับการใช้งานต่างๆ เช่น การควบคุมไฟ ล็อคประตู และมอเตอร์
พรีview คู่มือการใช้งานตัวควบคุมมอเตอร์เดินหน้า/ถอยหลัง QIACHIP 12V DC
คู่มือนี้ให้คำแนะนำในการใช้งานตัวควบคุมมอเตอร์เดินหน้า/ถอยหลัง QIACHIP 12V DC ซึ่งรวมถึงแผนผังสายไฟ คำอธิบายฟังก์ชัน วิธีการตั้งค่าโหมดชั่วขณะ โหมดสลับ และโหมดล็อก รวมถึงข้อมูลจำเพาะทางเทคนิค คู่มือนี้อธิบายวิธีจับคู่รีโมตคอนโทรลและรีเซ็ตอุปกรณ์
พรีview โมดูลรีเลย์ RF ไร้สาย QA-R-011 - คู่มือการใช้งานและข้อมูลจำเพาะของ QIACHIP
คู่มือฉบับสมบูรณ์สำหรับโมดูลรีเลย์ RF ไร้สาย QACHIP QA-R-011 ครอบคลุมแผนผังการเดินสาย คำแนะนำการตั้งค่าสำหรับโหมดการทำงานต่างๆ (โมเมนทารี, สลับ, แลตช์, หน่วงเวลา) และข้อมูลจำเพาะของผลิตภัณฑ์โดยละเอียด
พรีview โมดูลตัวรับสัญญาณไร้สาย 1 ช่อง QIACHIP KR1201B: คำแนะนำและการตั้งค่า
คำแนะนำโดยละเอียดและคู่มือการตั้งค่าสำหรับโมดูลตัวรับรีโมทคอนโทรลไร้สาย 1 ช่อง QIACHIP KR1201B รวมถึงแผนผังสายไฟและการกำหนดค่าโหมดการทำงาน
พรีview คู่มือผู้ใช้เครื่องรับสัญญาณรีโมทคอนโทรลไร้สาย QIACHIP KR1204B 12V 4 ช่อง
คู่มือผู้ใช้ฉบับสมบูรณ์สำหรับเครื่องรับสัญญาณรีโมทคอนโทรลไร้สาย QIACHIP KR1204B 12V 4 ช่อง ประกอบด้วยแผนผังสายไฟ โหมดการทำงาน (แบบ Momentary, Toggle, Latching), คำแนะนำในการตั้งค่า และข้อมูลจำเพาะทางเทคนิค
พรีview คู่มือการโคลนรีโมทคอนโทรล QACHIP 433.92Mhz
เรียนรู้วิธีโคลนรีโมตคอนโทรลของคุณด้วยเครื่องคัดลอก QIACHIP 433.92Mhz 4-in-1 คู่มือนี้ครอบคลุมการจับคู่ การล้างรหัส และโหมดการกู้คืนสำหรับประตูโรงรถและประตูรั้วไฟฟ้า