Apera Instruments AI1107

คู่มือผู้ใช้สารละลายบัฟเฟอร์สอบเทียบ pH 4.00 ของ Apera Instruments

สินค้าเกินview

The Apera Instruments pH 4.00 Calibration Buffer Solution is a high-quality standard designed for accurate pH meter calibration. This 16 oz. bottle contains a solution traceable to NIST Standard Reference Materials (SRMs), ensuring reliability and precision in your measurements.

คุณสมบัติที่สำคัญ ได้แก่:

  • ความแม่นยำ: Reported values are accurate to +/- 0.01 pH at 25 °C.
  • การผลิตที่มีคุณภาพ: Produced in an ISO 9001:2015 certified facility using high-purity reagents, deionized water, and certified analytical balances in a temperature-controlled environment.
  • การระบุตัวตน: Color-coded for quick and easy identification.
  • อายุการเก็บรักษา: Double-sealed with a 2-year expiration from manufacture for an unopened bottle.

การติดตั้งและการเตรียมการ

Before using the pH 4.00 calibration buffer solution, ensure your workspace is clean and free from contaminants. Follow these steps for optimal preparation:

  1. Inspect the Bottle: Verify the bottle is sealed and undamaged upon receipt. The solution is double-sealed for protection.
  2. ตรวจสอบวันหมดอายุ: Locate the expiration date on the bottle label. Do not use the solution past its expiration date.
  3. Temperature Acclimation: Allow the buffer solution to reach the ambient temperature of your calibration environment before use. This is crucial for accurate calibration, as pH values are temperature-dependent.
  4. Gentle Mixing: Gently invert the bottle a few times to ensure homogeneity before opening. Avoid vigorous shaking, which can introduce air bubbles.
ด้านหน้า view of Apera Instruments pH 4.00 Calibration Buffer Solution bottle

ภาพที่ 1: ด้านหน้า view of the Apera Instruments pH 4.00 Calibration Buffer Solution bottle, showing the label with product name, pH value, and volume.

Operating Instructions (Calibration Procedure)

This pH 4.00 buffer solution is used to calibrate pH meters. Always refer to your specific pH meter's instruction manual for detailed calibration steps. General steps for using this buffer are:

  1. Rinse Electrode: Before immersing the electrode in the buffer solution, rinse it thoroughly with distilled or deionized water.
  2. Immerse Electrode: Submerge the pH electrode into a sufficient amount of pH 4.00 buffer solution. Ensure the electrode's sensing bulb and reference junction are fully immersed.
  3. Stabilize Reading: Allow the pH meter reading to stabilize. This may take a few moments.
  4. ดำเนินการปรับเทียบ: Initiate the calibration process on your pH meter according to its specific instructions for a 2-point or 3-point calibration, typically starting with pH 7.00, then pH 4.00, and optionally pH 10.00.
  5. ล้างหลังการใช้งาน: After calibration with pH 4.00, rinse the electrode again with distilled or deionized water before proceeding to another buffer or sampเล.
กลับ view of Apera Instruments pH 4.00 Calibration Buffer Solution bottle with pH/Temperature Reference Chart

ภาพที่ 2: ด้านหลัง view of the Apera Instruments pH 4.00 Calibration Buffer Solution bottle, displaying a pH/Temperature Reference Chart. This chart shows the precise pH value of the solution at various temperatures, which is critical for accurate calibration.

การบำรุงรักษาและการเก็บรักษา

Proper maintenance and storage are essential to preserve the accuracy and shelf life of your pH 4.00 buffer solution:

  • อุณหภูมิในการจัดเก็บ: Store the bottle at room temperature, away from direct sunlight and extreme temperature fluctuations.
  • Keep Tightly Closed: Always recap the bottle tightly immediately after use to prevent evaporation and contamination.
  • หลีกเลี่ยงการปนเปื้อน: Never return used buffer solution to the original bottle. Pour out only the amount needed for calibration into a separate, clean beaker. Dispose of any unused portion from the beaker.
  • อายุการเก็บรักษา: The solution has a 2-year expiration from the date of manufacture when unopened. Once opened, its shelf life may be reduced depending on storage conditions and contamination.
สูงสุด view of Apera Instruments pH 4.00 Calibration Buffer Solution bottle showing the sealed cap

ภาพที่ 3: ด้านบน view of the Apera Instruments pH 4.00 Calibration Buffer Solution bottle, highlighting the double-sealed cap for product integrity and protection.

การแก้ไขปัญหา

If you encounter issues with your pH meter calibration using this buffer solution, consider the following:

  • Incorrect pH Reading: Ensure the buffer solution is at the same temperature as your pH meter's temperature compensation setting or the sample. Refer to the pH/Temperature Reference Chart on the bottle for accurate values at different temperatures.
  • Expired Solution: Check the expiration date. Expired buffer solutions can lead to inaccurate calibrations.
  • การปนเปื้อน: Verify that the buffer solution has not been contaminated by returning used solution to the bottle or by using unclean beakers/electrodes.
  • Electrode Issues: If problems persist, the issue might be with the pH electrode itself (e.g., dirty, dry, or aged). Refer to your pH meter's manual for electrode maintenance and troubleshooting.

ข้อมูลจำเพาะ

คุณลักษณะรายละเอียด
ชื่อสินค้าpH 4.00 Calibration Buffer Solution
ยี่ห้อเครื่องมือ Apera
หมายเลขรุ่นAI1107
ปริมาณ16 oz. (approximately 473 mL)
pH Value at 25°C4.00 +/- 0.01
การตรวจสอบย้อนกลับNIST Standard Reference Materials (SRMs)
มาตรฐานการผลิตISO 9001:2015 certified facility with ISO 17025:2017 accreditation
รูปร่างของเหลว
ขนาดแพ็คเกจ7.87 x 2.44 x 2.4 นิ้ว
น้ำหนักสินค้า1.17 ปอนด์
ยูพีซี810214030201

การสนับสนุนและทรัพยากร

For additional support, documentation, or inquiries, please refer to the following resources:

  • MSDS Documents: Material Safety Data Sheets (MSDS) are available for download to provide detailed information on the product's properties and safety precautions.
  • Certificate of Analysis: A Certificate of Analysis can be obtained upon request, verifying the quality and specifications of your specific batch.
  • ผู้ผลิต Webเว็บไซต์: Visit the official Apera Instruments website for comprehensive product information, FAQs, and contact details. www.apera.com
  • ร้านค้าอเมซอน: Explore other Apera Instruments products and resources on their Amazon store page. Apera Instruments Amazon Store

Note: This product is from a small business brand. Your support is appreciated.

เอกสารที่เกี่ยวข้อง - AI1107

พรีview เอกสารข้อมูลความปลอดภัยของสารละลายบัฟเฟอร์ pH 4.00 จาก APERA Instruments
เอกสารข้อมูลความปลอดภัย (SDS) สำหรับสารละลายบัฟเฟอร์ pH 4.00 ของ APERA Instruments ให้ข้อมูลที่สำคัญเกี่ยวกับการระบุตัวตน อันตราย การปฐมพยาบาล การจัดการ การเก็บรักษา และการปฏิบัติตามกฎระเบียบ
พรีview คู่มือผู้ใช้เครื่องวัดค่า pH อัจฉริยะ PH60Z-HT - Apera Instruments
คู่มือผู้ใช้สำหรับ Apera Instruments PH60Z-HT Smart pH Meter ซึ่งมีรายละเอียดเกี่ยวกับคุณลักษณะ การทำงาน การสอบเทียบ การบำรุงรักษา และการแก้ไขปัญหาสำหรับสารละลายที่อุณหภูมิสูงและกัดกร่อน
พรีview เครื่องทดสอบการนำไฟฟ้าแบบพกพา Apera EC20: คู่มือการใช้งานและคำแนะนำ
คู่มือการใช้งานฉบับสมบูรณ์สำหรับเครื่องทดสอบค่าการนำไฟฟ้าแบบพกพา Apera EC20 เรียนรู้เกี่ยวกับการตั้งค่า การสอบเทียบ การวัดค่าการนำไฟฟ้า ข้อมูลจำเพาะทางเทคนิค และข้อมูลการรับประกัน
พรีview เครื่องวัดค่า pH แบบพกพา Apera SX811-SS สำหรับการทดสอบอาหาร: คู่มือการใช้งานและข้อมูลจำเพาะ
คู่มือการใช้งานฉบับสมบูรณ์และข้อมูลทางเทคนิคสำหรับเครื่องวัดค่า pH แบบพกพา Apera SX811-SS ที่ออกแบบมาเพื่อการทดสอบอาหารอย่างแม่นยำ เรียนรู้เกี่ยวกับคุณสมบัติ การสอบเทียบ การตั้งค่า การสื่อสารผ่าน USB และการแก้ไขปัญหา
พรีview คู่มือผู้ใช้ชุดทดสอบค่า pH Apera Instruments PH1
คู่มือการใช้งานสำหรับชุดทดสอบค่า pH รุ่น PH1 จาก Apera Instruments ให้คำแนะนำโดยละเอียดเกี่ยวกับการติดตั้ง การสอบเทียบ การวัด การตั้งค่าพารามิเตอร์ ข้อมูลจำเพาะทางเทคนิค การดูแลรักษาหัววัด การแก้ไขปัญหา การเปลี่ยนแบตเตอรี่ และข้อมูลการรับประกัน
พรีview Apera Instruments Water Hardness Calibration Solution B1, B2, B3 Safety Data Sheet (SDS)
Safety Data Sheet (SDS) for Apera Instruments Water Hardness Calibration Solution B1, B2, B3, providing comprehensive information on identification, hazards, composition, first aid, firefighting, accidental release measures, handling, storage, exposure controls, physical and chemical properties, stability, reactivity, toxicological information, ecological information, disposal considerations, transport information, and regulatory information.