1. บทนำและเรื่องอื่นๆview
This manual provides essential information for the proper installation, operation, and maintenance of the Kidde K-278B-1120 Fire Alarm Pull Station. This device is designed to manually initiate a fire alarm signal within a conventional fire alarm system.
The Kidde K-278B-1120 is a double-action, key-reset pull station featuring a red finish and designed for wall mounting. It is intended for use with 24V DC/125V AC conventional fire alarm systems.
2. ข้อมูลด้านความปลอดภัย
คำแนะนำด้านความปลอดภัยที่สำคัญ:
- Installation of this fire alarm pull station should only be performed by qualified personnel in accordance with all local and national electrical codes and fire safety regulations.
- Always disconnect power to the fire alarm control panel before performing any installation, maintenance, or troubleshooting.
- ห้ามทาสีทับปุ่มกดแจ้งเหตุ หรือกีดขวางการใช้งานของปุ่มกดแจ้งเหตุไม่ว่าด้วยวิธีใดก็ตาม
- Regular testing of the fire alarm system, including pull stations, is crucial for ensuring proper functionality. Refer to local fire codes for testing frequency.
- This device is part of a life safety system. Any malfunction or damage must be addressed immediately by a qualified technician.
3 ส่วนประกอบ
The Kidde K-278B-1120 Fire Alarm Pull Station consists of the following primary components:
- Red Housing: The main body of the pull station, designed for visibility.
- รหัสเปิดใช้งาน: The mechanism labeled "PULL FOR FIRE" that is pulled to activate the alarm.
- ฝาครอบลิฟต์: The upper part of the handle mechanism, labeled "LIFT THEN PULL HANDLE," which must be lifted before the handle can be pulled.
- Key Reset Mechanism: A key-operated lock used to reset the pull station after activation.
- ขั้วต่อไฟฟ้า: Located inside the housing for connection to the fire alarm control panel wiring.
4. การตั้งค่าและการติดตั้ง
The Kidde K-278B-1120 Fire Alarm Pull Station is designed for wall mounting and integration into conventional fire alarm systems. Professional installation is highly recommended to ensure compliance with safety standards and proper system functionality.
4.1. การตรวจสอบก่อนการติดตั้ง
- Verify that the fire alarm control panel is compatible with a 24V DC or 125V AC manual pull station.
- Ensure the installation location meets local fire code requirements for visibility and accessibility.
- Confirm all necessary wiring and conduit are in place.
4.2. การติดตั้ง
- Turn off all power to the fire alarm control panel.
- Mount the pull station securely to a standard electrical box or directly to the wall using appropriate fasteners. Ensure it is level and firmly attached.
- Route the system wiring into the pull station's housing.
4.3. การเดินสาย
- Connect the fire alarm circuit wiring to the designated terminals inside the pull station. Refer to the wiring diagram provided with your fire alarm control panel and the pull station's internal labels for correct polarity and connections.
- ตรวจสอบให้แน่ใจว่าการเชื่อมต่อทั้งหมดปลอดภัยและเป็นฉนวน
- Close the pull station housing carefully after wiring is complete.
4.4. Post-Installation Test
After installation, power up the fire alarm control panel and perform a functional test of the pull station according to the fire alarm system's testing procedures. This typically involves activating the pull station and verifying that the alarm signal is received by the control panel and annunciated.
5. การดำเนินการ
The Kidde K-278B-1120 is a double-action pull station, requiring two distinct movements to activate the alarm.
5.1. การเปิดใช้งานสัญญาณเตือนภัย
- In the event of a fire or emergency requiring alarm activation, ยก the upper cover of the pull station, which is labeled "LIFT THEN PULL HANDLE".
- Once the cover is lifted, ดึงลงมา the handle labeled "PULL FOR FIRE" firmly.
- This action will send an alarm signal to the connected fire alarm control panel, initiating the building's fire alarm sequence.
5.2. การรีเซ็ตสถานีแจ้งเหตุฉุกเฉิน
After activation, the pull station must be reset using its key to return it to its normal, non-alarm state.
- Insert the provided reset key into the keyhole on the side or front of the pull station.
- Turn the key as indicated (usually a quarter turn) to release the activated handle.
- Return the handle to its original, upright position.
- Remove the key. The pull station is now reset and ready for future use.
6. การบำรุงรักษา
Regular maintenance ensures the reliability and longevity of your fire alarm pull station.
- การตรวจสอบภาพ: Periodically inspect the pull station for any signs of physical damage, tampering, or obstruction. Ensure the "LIFT THEN PULL HANDLE" and "PULL FOR FIRE" labels are clear and legible.
- การทำความสะอาด: Gently wipe the exterior of the pull station with a soft, damp ผ้า ห้ามใช้สารทำความสะอาดที่มีฤทธิ์กัดกร่อนหรือตัวทำละลาย
- การทดสอบฟังก์ชัน: Conduct periodic functional tests as required by local fire codes and the fire alarm system manufacturer's recommendations. This typically involves activating the pull station and verifying the alarm, then resetting it.
- การจัดการที่สำคัญ: Keep the reset key in a secure, accessible location known only to authorized personnel.
7 การแก้ไขปัญหา
If you encounter issues with your Kidde K-278B-1120 Fire Alarm Pull Station, consider the following:
| ปัญหา | สาเหตุที่เป็นไปได้ | สารละลาย |
|---|---|---|
| ปุ่มดึงสัญญาณเตือนภัยไม่ทำงาน | Improper wiring; Faulty pull station; Issue with fire alarm control panel. | Verify wiring connections. Test with a multimeter if qualified. Contact a qualified fire alarm technician for inspection and repair. |
| ไม่สามารถรีเซ็ตสถานีแจ้งเหตุฉุกเฉินได้ | Incorrect key; Damaged reset mechanism; Obstruction. | Ensure the correct key is used. Check for any physical obstructions. If mechanism is damaged, contact a qualified technician for replacement. |
| Alarm activates without pulling the handle. | Faulty pull station; Wiring short; Issue with fire alarm control panel. | Immediately contact a qualified fire alarm technician to diagnose and resolve the issue. This indicates a critical system fault. |
For any issues that cannot be resolved with the above steps, or for any concerns regarding the fire alarm system, always contact a qualified fire alarm system technician.
8. ข้อมูลจำเพาะ
| คุณลักษณะ | รายละเอียด |
|---|---|
| หมายเลขรุ่น | K-278B-1120 |
| ยี่ห้อ | คิดเด |
| สี | สีแดง |
| ประเภทการเปิดใช้งาน | Double Action (Lift then Pull) |
| รีเซ็ตประเภท | รีเซ็ตคีย์ |
| ประเภทการติดตั้ง | ติดตั้งบนผนัง |
| ขนาด (โดยประมาณ) | Length: 3 9/16 in (9.05 cm) Height: 5 3/16 in (13.18 cm) Depth: 3 5/8 in (9.21 cm) |
| น้ำหนัก | 0.8 ออนซ์ (ประมาณ 22.7 กรัม) |
| ความเข้ากันได้ | 24V DC / 125V AC Conventional Fire Alarm Systems |
| ช่วงความชื้น | สูงถึง 95% RH (ไม่ควบแน่น) |
9. การรับประกันและการสนับสนุน
For specific warranty information regarding your Kidde K-278B-1120 Fire Alarm Pull Station, please refer to the documentation included with your purchase or contact Kidde directly. Warranty terms may vary based on region and purchase date.
For technical support, product inquiries, or to locate authorized service providers, please visit the official Kidde webเว็บไซต์หรือติดต่อฝ่ายบริการลูกค้าของพวกเขา
You can find more information about Kidde products by visiting the Kidde Store on Amazon.