Ranco O18-100

คู่มือการใช้งาน Ranco Ice Bank Control O18-100

รุ่น: O18-100

การแนะนำ

This manual provides comprehensive instructions for the installation, operation, and maintenance of the Ranco Ice Bank Control, Model O18-100. This device is designed to accurately control ice thickness in ice bank systems by utilizing a water-filled bulb and transmission fluid.

Please read this manual thoroughly before attempting to install or operate the control to ensure proper function and safety.

ข้อมูลด้านความปลอดภัย

คำแนะนำด้านความปลอดภัยที่สำคัญ:

  • Always disconnect power before installing or servicing the control.
  • Installation should be performed by a qualified technician in accordance with all local and national electrical codes.
  • Do not modify the control or its components.
  • ตรวจสอบให้แน่ใจว่าการเชื่อมต่อทั้งหมดมีความปลอดภัยและมีฉนวนป้องกันอย่างเหมาะสม
  • Keep the control away from excessive moisture or corrosive environments.

สินค้าเกินview

The Ranco Ice Bank Control O18-100 is a mechanical device designed to sense and regulate the thickness of ice in an ice bank refrigeration system. It consists of a main control unit and a capillary tube with a sensing bulb.

Ranco Ice Bank Control O18-100 with main unit and coiled capillary tube with sensing bulb

รูปที่ 1: Ranco Ice Bank Control O18-100. The image displays the gray main control unit with the Ranco logo and a visible adjustment screw. Below it, a coiled copper capillary tube extends to a metallic sensing bulb.

ส่วนประกอบหลัก:

  • หน่วยควบคุม: The main housing containing the electrical contacts and adjustment mechanism. It is gray and measures approximately 2 5/8 inches in height, 1 7/8 inches in width, and 3 1/4 inches in depth.
  • หลอดแคปิลลารี: A thin copper tube connecting the control unit to the sensing bulb.
  • หลอดไฟตรวจจับ: A water-filled bulb that detects the ice thickness. It contains transmission fluid which expands or contracts with temperature changes, transmitting pressure through the capillary tube to the control unit.
  • Adjustment Screw: Located on the front of the control unit, used to set the desired ice thickness.

ข้อมูลจำเพาะ

คุณสมบัติข้อมูลจำเพาะ
ประเภทสินค้าIce Bank Control
หมายเลขรุ่นO18-100
ยี่ห้อรันโก้
วัสดุโลหะ
สีสีเทา
ความสูงรวม2 5/8 นิ้ว
ความกว้างรวม1 7/8 นิ้ว
ความลึกโดยรวม3 1/4 นิ้ว
ขนาดสินค้า6 x 4 x 2 inches (packaging/shipping)
น้ำหนักสินค้า1 ปอนด์
คุณสมบัติUses water-filled bulb and transmission fluid to control ice thickness.
ยูพีซี662013922863

การติดตั้งและการตั้งค่า

Proper installation is crucial for the accurate and reliable operation of the Ranco Ice Bank Control. Consult a qualified refrigeration technician for installation.

  1. การตัดการเชื่อมต่อไฟฟ้า: Ensure all power to the refrigeration system is disconnected at the main breaker before beginning installation.
  2. Mounting the Control Unit: Mount the main control unit in a location that is easily accessible for adjustment and wiring, but protected from physical damage and excessive moisture. Use appropriate fasteners for secure mounting.
  3. Sensing Bulb Placement: The sensing bulb must be positioned within the ice bank tank where ice formation occurs. It should be submerged in the water and located at the desired ice thickness level. Ensure the capillary tube is routed carefully to avoid kinks or damage.
  4. สายไฟฟ้า: Connect the control unit to the refrigeration compressor's control circuit according to the wiring diagram provided with your specific refrigeration system. The Ranco O18-100 acts as a switch to cycle the compressor based on ice thickness. Refer to local electrical codes for proper wiring practices.
  5. การตรวจสอบระบบ: After wiring, restore power and verify that the refrigeration system operates correctly.

คำแนะนำการใช้งาน

The Ranco Ice Bank Control O18-100 is designed for automatic operation once properly installed and adjusted.

  1. การปรับแต่งเบื้องต้น: The adjustment screw on the front of the control unit allows for fine-tuning the ice thickness. Turning the screw clockwise typically increases the desired ice thickness, while turning it counter-clockwise decreases it.
  2. Monitoring Ice Thickness: After initial adjustment, monitor the ice thickness in the bank over several cycles. Make small adjustments to the screw as needed until the desired ice thickness is consistently achieved.
  3. หลักการทำงาน: As ice forms around the sensing bulb, the water inside the bulb freezes and expands. This expansion creates pressure in the transmission fluid, which is conveyed through the capillary tube to the control unit. When the pressure reaches a preset point (corresponding to the desired ice thickness), the control unit opens a switch, stopping the compressor. As ice melts, the pressure decreases, and the control unit closes the switch, restarting the compressor to build ice again.

การซ่อมบำรุง

The Ranco Ice Bank Control O18-100 requires minimal maintenance. Regular checks can help ensure its longevity and proper function.

  • การตรวจสอบภาพ: Periodically inspect the control unit, capillary tube, and sensing bulb for any signs of physical damage, corrosion, or leaks.
  • ความสะอาด : Ensure the sensing bulb is free from excessive scale or debris that could impede its ability to accurately sense ice formation. Clean gently if necessary.
  • การเชื่อมต่อไฟฟ้า: Annually, or as part of routine system maintenance, verify that all electrical connections are tight and free from corrosion.

การแก้ไขปัญหา

If you experience issues with your Ranco Ice Bank Control, consider the following common troubleshooting steps. For complex issues, contact a qualified technician.

ปัญหาสาเหตุที่เป็นไปได้สารละลาย
No Ice Formation / Compressor Not Running
  • ไม่มีอำนาจที่จะควบคุม
  • สายไฟชำรุด
  • Sensing bulb not submerged or damaged.
  • หน่วยควบคุมทำงานผิดปกติ
  • ตรวจสอบแหล่งจ่ายไฟและเบรกเกอร์
  • ตรวจสอบการเชื่อมต่อไฟฟ้าทั้งหมด
  • Verify bulb placement and integrity.
  • Test control unit with a multimeter (by qualified technician).
Excessive Ice Formation / Compressor Runs Continuously
  • Control set too high.
  • Sensing bulb not freezing properly.
  • Capillary tube kinked or damaged.
  • หน่วยควบคุมทำงานผิดปกติ
  • Adjust the ice thickness setting counter-clockwise.
  • Ensure bulb is fully submerged and water is freezing around it.
  • Inspect capillary tube for damage.
  • Test control unit (by qualified technician).
Inconsistent Ice Thickness
  • Improper bulb placement.
  • Fluctuations in water level or temperature.
  • Control unit drift.
  • Re-position sensing bulb for optimal ice sensing.
  • Ensure stable operating conditions for the ice bank.
  • Consider replacement if control unit is old or unreliable.

การรับประกันและการสนับสนุน

For warranty information or technical support regarding your Ranco Ice Bank Control O18-100, please refer to the documentation provided at the point of purchase or contact Ranco customer service directly. Keep your purchase receipt as proof of purchase.

ผู้ผลิต: รันโก้

แบบอย่าง: O18-100

เอกสารที่เกี่ยวข้อง - O18-100

พรีview แรนโค อีทีซี ทู เอสtage. ระบบควบคุมอุณหภูมิแบบอิเล็กทรอนิกส์ - ข้อมูลการติดตั้งแบบ NEMA Type 4X
ข้อมูลการติดตั้ง ข้อมูลจำเพาะ การใช้งาน และการแก้ไขปัญหาสำหรับ Ranco ETC Two Stage ตัวควบคุมอุณหภูมิแบบอิเล็กทรอนิกส์ NEMA Type 4X ตัวควบคุมนี้ออกแบบมาสำหรับระบบปรับอากาศและระบบทำความเย็นเชิงพาณิชย์ โดยมีโหมดการทำงานแบบคู่tagมีระบบควบคุมอุณหภูมิ, จอแสดงผล LCD, การตั้งโปรแกรมด้วยปุ่มกด และตัวเรือนกันน้ำระดับ NEMA 4X สำหรับใช้งานกลางแจ้ง
พรีview Ranco ETC ซิงเกิล เอสtage. คู่มือการติดตั้งระบบควบคุมอุณหภูมิอิเล็กทรอนิกส์
คู่มือการติดตั้ง การใช้งาน และการแก้ไขปัญหาอย่างละเอียดสำหรับ Ranco ETC Single Stage. การควบคุมอุณหภูมิแบบอิเล็กทรอนิกส์ ครอบคลุมรายละเอียดผลิตภัณฑ์ การใช้งาน คุณสมบัติ ข้อมูลจำเพาะ การสั่งซื้อ การตั้งโปรแกรม สวิตช์ล็อค แผนผังการเดินสายไฟ และข้อมูลเซ็นเซอร์สำหรับระบบปรับอากาศและระบบทำความเย็น
พรีview ข้อมูลการติดตั้งระบบควบคุมแรงดันเดี่ยว Ranco
ข้อมูลการติดตั้งสำหรับตัวควบคุมแรงดันเดี่ยวของ Ranco (010, 011, 016, 020) ครอบคลุมคำอธิบาย การใช้งาน การติดตั้ง การเดินสายไฟ และการตั้งค่าการควบคุมสำหรับสารทำความเย็นและช่วงแรงดันต่างๆ
พรีview ข้อมูลการติดตั้งชุดควบคุมแรงดันเดี่ยว Ranco O10/O11/O16/O20
ข้อมูลการติดตั้ง การเดินสายไฟ การตั้งค่า และข้อกำหนดโดยละเอียดสำหรับตัวควบคุมแรงดันเดี่ยว Ranco รุ่น O10, O11, O16 และ O20 ที่ใช้ในระบบทำความเย็นและเครื่องปรับอากาศเชิงพาณิชย์ รวมถึงคำแนะนำในการติดตั้ง การดูแลรักษาท่อแคปิลลารี การเดินสายไฟควบคุม ขั้นตอนการปรับแต่ง และข้อกำหนดโดยละเอียด
พรีview แคตตาล็อกระบบควบคุมเครื่องทำความเย็น Ranco, Johnson Controls และ Danfoss
แค็ตตาล็อกที่ครอบคลุมของการควบคุมอุณหภูมิและแรงดันจาก Ranco, Johnson Controls และ Danfoss รวมถึงการควบคุมขีดจำกัดแรงดันต่ำ การควบคุมแรงดันสูง-ต่ำ การควบคุมอิเล็กทรอนิกส์ การควบคุมการละลายน้ำแข็ง และอุปกรณ์เสริมสำหรับระบบทำความเย็น
พรีview คู่มือการใช้งาน การบำรุงรักษา และชิ้นส่วนของรถพ่วงดัมพ์ท้าย Ranco
คู่มือฉบับสมบูรณ์สำหรับรถพ่วงดัมพ์ท้ายกระบะ Ranco ครอบคลุมการใช้งาน การบำรุงรักษา ชิ้นส่วน ระบบไฟฟ้า ระบบเบรกอากาศ และระบบช่วงล่าง จำเป็นอย่างยิ่งสำหรับการใช้งานและการดูแลรักษาอย่างถูกต้อง