APC AP7801B

APC Rack PDU, Metered, 1U, 20A, 120V, 8 5-20 Instruction Manual

Model: AP7801B

การแนะนำ

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your APC Metered Rack Power Distribution Unit (PDU), Model AP7801B. Please read this manual thoroughly before installation and operation to ensure proper use and to prevent damage to the unit or connected equipment.

ข้อมูลด้านความปลอดภัยที่สำคัญ

Observe the following safety precautions to reduce the risk of electric shock, fire, or injury:

สินค้าเกินview

The APC Metered Rack PDU (Model AP7801B) is a 1U rack-mountable power distribution unit designed to provide reliable power distribution and real-time current monitoring for IT equipment in data centers and server rooms. It features eight NEMA 5-20R outlets.

APC Metered Rack PDU AP7801B with 8 NEMA 5-20R outlets

Image: A black 1U rack-mountable Power Distribution Unit (PDU) with eight NEMA 5-20R outlets numbered 1 through 8 on the front. The unit also features a digital display showing current draw, status indicators, and a network port on the right side.

คุณสมบัติแผงด้านหน้า

การตั้งค่า

1. การแกะกล่อง

Carefully remove the PDU and all accessories from its packaging. Inspect the unit for any signs of shipping damage. If damage is found, contact your dealer or APC customer support immediately.

2. Mounting the PDU

The AP7801B is designed for 1U rack mounting. Use the provided mounting hardware to secure the PDU horizontally in a standard 19-inch equipment rack. Ensure adequate airflow around the unit.

3. Connecting Input Power

Connect the PDU's input power cord to a dedicated 20A, 120V NEMA 5-20R wall receptacle or an appropriate upstream power source. Ensure the power source is properly grounded.

4. การเชื่อมต่ออุปกรณ์

Plug your IT equipment's power cords into the NEMA 5-20R outlets on the front of the PDU. Distribute the load evenly across the outlets if possible, and ensure the total current draw does not exceed 20 Amps.

5. การเชื่อมต่อเครือข่าย (ทางเลือก)

For remote monitoring, connect a standard Ethernet cable from the PDU's network port to your network switch or router. Refer to the network management card documentation for initial network configuration.

การดำเนินงาน

การเปิดเครื่อง

Once the PDU is connected to a power source and equipment is plugged in, the PDU will automatically power on. The digital display will illuminate, showing the total current draw in Amps.

ตรวจสอบปัจจุบัน

The front panel digital display provides a real-time readout of the total current being drawn by all connected equipment. Monitor this value to ensure it remains below the PDU's maximum capacity of 20 Amps.

Remote Monitoring (via Network)

If connected to a network, the PDU's embedded network management card allows for remote monitoring of current, environmental conditions (with optional sensors), and event logging through a web browser interface or network management system. Consult the network management card user guide for detailed instructions on accessing and configuring these features.

การซ่อมบำรุง

The APC Metered Rack PDU is designed for minimal maintenance. However, regular inspection and cleaning can help ensure optimal performance and longevity.

การแก้ไขปัญหา

This section provides solutions to common issues you may encounter with your PDU.

ปัญหาสาเหตุที่เป็นไปได้สารละลาย
PDU has no power.Input power cord is disconnected or upstream circuit breaker is tripped.Ensure the input power cord is securely connected. Check and reset the upstream circuit breaker if necessary.
Digital display shows 'OL' or an overload alarm.Total current draw exceeds the PDU's 20A capacity.Reduce the load by disconnecting some equipment or redistributing it to another PDU.
Connected equipment is not receiving power.Equipment power cord is loose or faulty. PDU may be overloaded.Check equipment power cords. Verify PDU is not overloaded. Test equipment with a known good power source.
Cannot access PDU via network.Incorrect network settings, cable issue, or network problem.Verify Ethernet cable connection. Check network settings (IP address, subnet mask, gateway). Consult network management card documentation for reset procedures if needed.

ข้อมูลจำเพาะทางเทคนิค

The following table details the technical specifications for the APC Metered Rack PDU, Model AP7801B:

ข้อมูลจำเพาะค่า
ยี่ห้อเอพีซี
หมายเลขรุ่นเอพี7801บี
ฟอร์มแฟกเตอร์แร็ค (1U)
อินพุต Voltage120 โวลต์ (AC)
ป้อนข้อมูล Ampอีเรจ20 Amps
ปริมาณการส่งออกtage120 โวลต์ (AC)
กระแสไฟขาออก20 Amps
จำนวนจุดจำหน่าย8
ประเภทขั้วต่อนีมา 5-20R
ประเภทปลั๊กไฟNEMA 5-20P (Type L)
วัดtage2400 วัตต์
ช่วงความถี่50/60 เฮิรตซ์
ขนาดรายการ (ยาว x กว้าง x สูง)19.5 x 13.4 x 2.9 นิ้ว
น้ำหนักสินค้า6.4 ปอนด์
สีสีดำ
ยูพีซี731304331469
ASINB06XG2TY7H

การรับประกันและการสนับสนุน

ข้อมูลการรับประกัน

APC products typically come with a standard manufacturer's warranty. Please refer to the warranty card included with your product or visit the official APC website for detailed warranty terms and conditions specific to the AP7801B model.

การสนับสนุนลูกค้า

For technical assistance, troubleshooting, or product inquiries, please contact APC customer support. Contact information can usually be found on the APC website or in the product packaging. When contacting support, please have your model number (AP7801B) and serial number readily available.

เอกสารที่เกี่ยวข้อง - เอพี7801บี

พรีview APC Easy PDU Metered-by-Outlet Rack Power Distribution Unit Installation Guide
Installation guide for APC Easy PDU Metered-by-Outlet Rack Power Distribution Units (EPDU2116MBO, EPDU2132MBO, EPDU2216MBO, EPDU2232MBO), covering safety, installation, display interface, and specifications.
พรีview คู่มือการติดตั้ง APC Rack Power Distribution Unit
คู่มือการติดตั้งอุปกรณ์จ่ายไฟแบบแร็ค (PDU) ของ APC รวมถึงข้อควรระวังด้านความปลอดภัย ขั้นตอนการติดตั้ง และข้อมูลเกี่ยวกับอินเทอร์เฟซจอแสดงผล
พรีview คู่มือการติดตั้งชุดจ่ายไฟแบบสวิตช์สำหรับแร็คของ APC
คู่มือการติดตั้งและการใช้งานสำหรับอุปกรณ์จ่ายไฟแบบสวิตช์สำหรับตู้แร็ค (PDU) ของ APC ครอบคลุมคุณสมบัติ การติดตั้ง การกำหนดค่า การเข้าถึง การรับประกัน และการสนับสนุน
พรีview คู่มือการติดตั้งและเปลี่ยน PDU รุ่น APC SMT2200/SMT3000 | Schneider Electric
คู่มือนี้ให้คำแนะนำในการติดตั้งแผง PDU สำหรับเปลี่ยนทดแทน (อุปกรณ์เสริม) สำหรับระบบ UPS รุ่น APC SMT2200 และ SMT3000 ประกอบด้วยข้อความสำคัญด้านความปลอดภัย แนวทางการจัดการผลิตภัณฑ์ และขั้นตอนการติดตั้งอย่างละเอียด
พรีview คู่มือผลิตภัณฑ์ APC NetShelter Rack PDU Advanced & Rack Systems
คู่มือฉบับสมบูรณ์เกี่ยวกับ APC NetShelter Rack PDU รวมถึงรุ่นขั้นสูงแบบ 4-in-1, รุ่นพื้นฐาน, แบบวัดค่า, แบบสวิตช์ และแบบวัดค่าตามแต่ละเต้ารับ สำหรับการจัดการพลังงานในศูนย์ข้อมูล มีข้อมูลจำเพาะ อุปกรณ์เสริม และโซลูชันสำหรับระบบแร็ค
พรีview เอกสารข้อมูลและข้อมูลจำเพาะทางเทคนิคของ APC Smart-UPS SRT 3000VA 208V
เอกสารข้อมูลทางเทคนิคฉบับสมบูรณ์สำหรับเครื่องสำรองไฟ APC Smart-UPS SRT 3000VA 208V ซึ่งให้รายละเอียดเกี่ยวกับข้อกำหนดทางไฟฟ้า คุณลักษณะทางกายภาพ ความสามารถในการทำงาน สภาพแวดล้อมในการทำงาน และการรับรองผลิตภัณฑ์