1. บทนำ
This manual provides essential instructions for the safe and efficient operation, installation, and maintenance of your Steinbach SPS 50-1T self-priming filter pump. Please read this manual thoroughly before operating the pump to ensure proper function and longevity of the product. This filter pump is designed for use with swimming pools up to approximately 22,000 liters water content.
2. คำแนะนำด้านความปลอดภัย
สำคัญ: Always disconnect the pump from the power supply before performing any installation, maintenance, or cleaning tasks.
- Ensure the power supply matches the pump's specifications (230V/250W).
- The pump must be installed on a stable, level surface, protected from direct weather exposure.
- ห้ามใช้งานปั๊มหากสายไฟหรือปลั๊กชำรุดเสียหาย
- โปรดกันเด็กและบุคคลที่ไม่ได้รับอนุญาตให้เข้าใกล้ปั๊มขณะใช้งาน
- Never run the pump dry. Ensure the pump is filled with water before starting.
- The maximum water temperature for operation is 35°C.
- All electrical connections should be performed by a qualified electrician and comply with local regulations.
3. สินค้าหมดview และส่วนประกอบ
The Steinbach SPS 50-1T is a self-priming filter pump equipped with a pre-filter and an integrated timer. Familiarize yourself with the main components:

รูปที่ 1: โดยรวม view of the Steinbach SPS 50-1T filter pump, showing the motor, pump housing, pre-filter, and control panel.
- มอเตอร์: The electrical unit that drives the pump impeller.
- ที่อยู่อาศัยปั๊ม: Contains the impeller and directs water flow.
- ตัวกรองล่วงหน้า: A transparent chamber with a removable basket designed to capture larger debris before it reaches the pump impeller, protecting the pump from damage.
- ทางเข้า/ทางออกการเชื่อมต่อ: Points for connecting hoses (Ø 32/38 mm).
- แผงควบคุม: Features ON/OFF and TIMER buttons, along with indicator lights for setting operation duration.

รูปที่ 2: รายละเอียด view of the pre-filter assembly, showing the transparent lid and the hose connection point for the inlet.

รูปที่ 3: The pump's control panel, featuring the ON/OFF button, TIMER button, and indicator lights for setting operational hours.
4. การตั้งค่าและการติดตั้ง
- การจัดวาง: Position the pump on a firm, level surface, ideally below the water level of the pool for easier priming. Ensure it is protected from rain and direct sunlight.
- การเชื่อมต่อท่อ: Connect the pool's skimmer line to the pump's inlet (pre-filter side) and the return line to the pump's outlet. Use hoses with a diameter of Ø 32/38 mm. Secure all connections with hose clamps เพื่อป้องกันการรั่วไหล

รูปที่ 4: View of the threaded inlet and outlet ports on the pump, ready for hose adapters.
- การเตรียมปั๊ม: Before starting, ensure the pre-filter is filled with water. If the pump is above water level, it may require manual priming by filling the pre-filter chamber until water flows into the pump housing.
- การเชื่อมต่อไฟฟ้า: Plug the pump into a grounded electrical outlet (230V). Ensure the outlet is protected by a Residual Current Device (RCD) for safety.
5. คู่มือการใช้งาน
เมื่อติดตั้งและเตรียมพร้อมใช้งานแล้ว ปั๊มก็พร้อมใช้งานได้ทันที
5.1 การใช้งานแบบแมนนวล
- กดปุ่ม เปิด/ปิด button on the control panel to start the pump.
- กดปุ่ม เปิด/ปิด button again to stop the pump.
5.2 ฟังก์ชั่นจับเวลา
The integrated timer allows for automated operation cycles.
- Ensure the pump is connected to power.
- กดปุ่ม ตัวจับเวลา button repeatedly to select the desired operating duration (e.g., 2, 4, 6, 8, 10, 12, 14, 16, 24 hours). The corresponding indicator light will illuminate.
- The pump will start and run for the selected duration, then automatically shut off.
- The timer cycle will repeat daily at the same time it was initially set. To reset the timer, unplug the pump for a few seconds and then plug it back in.
6. การบำรุงรักษา
การบำรุงรักษาอย่างสม่ำเสมอจะช่วยให้ปั๊มทำงานได้อย่างมีประสิทธิภาพสูงสุดและยืดอายุการใช้งานของปั๊มได้
6.1 Cleaning the Pre-filter Basket
- ถอดปั๊มออกจากแหล่งจ่ายไฟ
- Close any valves to prevent water flow from the pool.
- Unscrew the transparent lid of the pre-filter.
- Remove the pre-filter basket and clean it thoroughly under running water.
- Inspect the O-ring seal on the lid for damage and ensure it is clean.
- Replace the basket, secure the lid, and open the valves.
- หากจำเป็น ให้เติมลมปั๊มอีกครั้งก่อนเริ่มใช้งาน

รูปที่ 5: The pre-filter chamber with its transparent lid removed, showing the internal basket for debris collection.
6.2 ฤดูหนาว
- At the end of the swimming season, disconnect the pump from power and drain all water from the pump and hoses to prevent freezing damage.
- Clean the pump thoroughly and store it in a dry, frost-free location.
7 การแก้ไขปัญหา
| ปัญหา | สาเหตุที่เป็นไปได้ | สารละลาย |
|---|---|---|
| ปั๊มไม่ทำงาน | No power; tripped circuit breaker; motor overload. | Check power connection; reset circuit breaker; allow motor to cool. |
| ปั๊มทำงานแต่ไม่มีน้ำไหล | Pump not primed; air leak in suction line; clogged pre-filter basket; closed valves. | Prime the pump; check all connections for leaks; clean pre-filter; open all valves. |
| ลดการไหลของน้ำ | Partially clogged pre-filter; restricted suction or return lines; low water level in pool. | Clean pre-filter; check and clear hoses; ensure adequate pool water level. |
| เสียงดังเกินไป | Air in pump; cavitation; motor bearing wear. | Ensure pump is fully primed and no air leaks; check for obstructions in suction line; contact service if motor noise persists. |
8. ข้อมูลจำเพาะทางเทคนิค
| คุณสมบัติ | ข้อมูลจำเพาะ |
|---|---|
| แบบอย่าง | SPS 50-1T (040949) |
| แหล่งจ่ายไฟ | 230V/50Hz. แรงดันไฟฟ้า |
| การใช้พลังงาน | 250 วัตต์ |
| Pump Power (Flow Rate) | 7,020 liters/hour (Q= 117 l/min) |
| ความสูงสูงสุดของปั๊ม (เฮด) | 7.5 เมตร |
| ประเภทปั๊ม | Self-priming with Pre-Filter |
| การเชื่อมต่อท่อ | Ø 32/38 มม. |
| อุณหภูมิน้ำสูงสุด | 35 องศาเซลเซียส |
| Maximum Pool Size | 22,000 ลิตร |
| ระดับเสียง | ประมาณ 70 เดซิเบล |
| คุณสมบัติแบบบูรณาการ | ตัวจับเวลา |
| ขนาดสินค้า | 1 x 1 x 1 ซม. |
| น้ำหนักสินค้า | 6 กิโลกรัม |
| วัสดุ | Metal (motor housing), Plastic (pump housing, pre-filter) |
9. การรับประกันและการสนับสนุน
For warranty information, technical support, or spare parts, please refer to the documentation provided with your purchase or contact Steinbach customer service. Keep your proof of purchase for warranty claims.
You can find more information and contact details on the official Steinbach webเว็บไซต์: www.steinbach.at