FORA Painless Design Adjustable Lancing Device

คู่มือการใช้งานอุปกรณ์เจาะเลือดแบบปรับได้ FORA ดีไซน์ไร้ความเจ็บปวด

Model: Painless Design Adjustable Lancing Device

1. บทนำ

Thank you for choosing the FORA Painless Design Adjustable Lancing Device. This device is designed to assist in obtaining blood samples for glucose monitoring with enhanced comfort and safety. Please read this manual thoroughly before using the device to ensure proper operation and to understand all safety precautions.

คุณสมบัติหลัก:

2. ข้อมูลด้านความปลอดภัย

Always follow basic safety precautions when using this lancing device to reduce the risk of injury or infection.

3. สินค้าหมดview

Familiarize yourself with the components of your FORA Lancing Device:

Diagram of FORA Lancing Device components: Cap, Depth indicator, Ejector, Release Button.

รูปที่ 3.1: Components of the FORA Lancing Device. This diagram illustrates the main parts: the protective cap, the depth indicator for setting penetration level, the ejector mechanism for safe lancet removal, and the release button to activate the lancing action.

4. การตั้งค่า

4.1 Inserting a Lancet

  1. Unscrew the cap from the lancing device.
  2. เสียบเข็มเจาะเลือดใหม่ที่ผ่านการฆ่าเชื้อแล้วลงในที่ยึดเข็มเจาะเลือดให้แน่น
  3. Twist off the protective cap from the lancet. Retain this cap for safe disposal later.
  4. Replace the lancing device cap by screwing it back on.

4.2 Adjusting Penetration Depth

The lancing device features 6 adjustable depth settings. Rotate the cap to select the desired depth. A higher number indicates a deeper penetration.

Three-step illustration for collecting blood samples: 1. Select desired depth, 2. Pull cocking control back, 3. Lance the finger.

รูปที่ 4.1: Steps for preparing and using the lancing device. This image demonstrates selecting the penetration depth, cocking the device, and performing a finger prick.

5. คู่มือการใช้งาน

5.1 Performing a Blood Sample (Fingerstick)

  1. Wash your hands thoroughly with soap and warm water, then dry them completely.
  2. Ensure a new lancet is inserted and the depth setting is appropriate for your skin type (refer to Section 4.2).
  3. Pull the cocking control back until it clicks. The device is now armed.
  4. วางอุปกรณ์เจาะเลือดให้แน่นที่ด้านข้างปลายนิ้วของคุณ
  5. Press the release button to activate the lancet.
  6. Gently massage your finger from the base towards the tip to form a blood drop. Do not squeeze excessively.
  7. Apply the blood drop to your glucose meter test strip as instructed by your meter's manual.

5.2 Alternative Site Testing (AST)

The FORA Lancing Device includes a clear alternate site end cap for testing on areas other than the fingertip, such as the forearm or palm. Consult your healthcare professional before performing AST, as results from alternative sites may differ from fingertip results, especially during periods of rapid glucose change.

  1. Remove the standard cap and replace it with the clear AST cap.
  2. Select a suitable depth setting (AST generally requires a deeper setting due to thicker skin).
  3. Pull the cocking control back until it clicks.
  4. Press the clear AST cap firmly against the chosen alternative site (e.g., forearm or palm) and hold for a few seconds to create a vacuum.
  5. กดปุ่มปล่อย
  6. Gently massage the area to form a blood drop.
  7. Apply the blood drop to your glucose meter test strip.

5.3 Safely Disposing of a Used Lancet

Proper disposal of used lancets is crucial to prevent accidental needle sticks and the spread of infection.

Two-step illustration for safely disposing of a used lancet: 1. Safely dispose by pushing the exposed tip into a protective disk, 2. Slide the ejector forward to remove the used lancet.

รูปที่ 5.1: Steps for safe lancet disposal. This image shows how to cap the lancet and then use the ejector mechanism to remove it from the device.

  1. คลายเกลียวฝาอุปกรณ์กรีด
  2. Carefully place the protective cap (removed in Section 4.1) back onto the used lancet, ensuring the needle is fully covered. Alternatively, if your lancets come with a protective disk, push the exposed tip into the disk on a hard surface.
  3. Slide the ejector forward to release the capped lancet into an approved sharps container.
  4. เปลี่ยนฝาครอบอุปกรณ์เจาะ

6. การบำรุงรักษา

6.1 Cleaning the Lancing Device

6.2 พื้นที่จัดเก็บ

7 การแก้ไขปัญหา

If you encounter issues with your lancing device, refer to the table below for common problems and solutions.

ปัญหาสาเหตุที่เป็นไปได้สารละลาย
Device does not cock or fire.Device not fully cocked; lancet not inserted correctly; device malfunction.Ensure the cocking control is pulled back until it clicks. Re-insert lancet. If problem persists, contact customer support.
เลือดไม่เพียงพอ sampเล.Depth setting too shallow; insufficient blood flow; cold hands.Increase depth setting. Warm hands before testing. Gently massage the lanced area.
Pain during lancing.Depth setting too deep; reused lancet; lancing on calloused area.Decrease depth setting. Always use a new lancet. Choose a different lancing site.
Lancet cannot be ejected.Lancet stuck; ejector mechanism obstructed.Ensure the cap is removed. Gently try to slide the ejector. If stuck, carefully remove with tweezers and dispose of safely.

8. ข้อมูลจำเพาะ

คุณสมบัติรายละเอียด
แบบอย่างPainless Design Adjustable Lancing Device
การตั้งค่าความลึกปรับได้ 6 ระดับ
Lancet CompatibilityMost standard lancets (28-33 gauge)
ขนาดประมาณ 6.1 x 3.2 x 1 นิ้ว
น้ำหนักประมาณ 1.6 ออนซ์
ผู้ผลิตForaCare Inc.
ASINB01INS8T5I

9. การรับประกันและการสนับสนุน

For warranty information, technical support, or to purchase accessories, please contact FORA customer service or visit the official FORA webเว็บไซต์.

You can find more information about FORA products and support at the FORA Store on Amazon.

เอกสารที่เกี่ยวข้อง - Painless Design Adjustable Lancing Device

พรีview ข้อมูลผู้ใช้และความแม่นยำของแถบทดสอบระดับน้ำตาลในเลือด FORA 6
คู่มือฉบับสมบูรณ์สำหรับแผ่นตรวจระดับน้ำตาลในเลือด FORA 6 ครอบคลุมคำเตือน วัตถุประสงค์การใช้งาน ข้อจำกัด การจัดการ ขั้นตอนการทดสอบ การตีความผล การควบคุมคุณภาพ องค์ประกอบทางเคมี ข้อมูลความแม่นยำ และการศึกษาประสิทธิภาพของผู้ใช้ มีข้อมูลสำหรับบุคลากรทางการแพทย์และการทดสอบด้วยตนเอง
พรีview คู่มือผู้ใช้เครื่องวัดระดับน้ำตาลในเลือด FORA Diamond MINI
คู่มือฉบับย่อสำหรับการใช้เครื่องวัดระดับน้ำตาลในเลือด FORA Diamond MINI เพื่อการทดสอบด้วยตนเอง เรียนรู้วิธีการวัดระดับน้ำตาลในเลือดอย่างแม่นยำและปลอดภัยพร้อมคำแนะนำทีละขั้นตอน
พรีview เครื่องวัดระดับน้ำตาลในเลือด FORA Diamond GD50: คู่มือการใช้งาน
คู่มือนี้ให้คำแนะนำทีละขั้นตอนสำหรับการใช้เครื่องวัดระดับน้ำตาลในเลือด FORA Diamond GD50 เพื่อการทดสอบด้วยตนเอง เรียนรู้วิธีการเตรียมอุปกรณ์ ทดสอบระดับน้ำตาลในเลือด และกำจัดวัสดุที่ใช้แล้วอย่างปลอดภัย
พรีview แถบทดสอบน้ำตาลในเลือด FORA 6 - คู่มือผู้ใช้และข้อมูลจำเพาะ
เอกสารนี้ให้ข้อมูลที่ครอบคลุมเกี่ยวกับแถบตรวจน้ำตาลในเลือด FORA 6 ซึ่งรวมถึงวัตถุประสงค์การใช้งาน ข้อจำกัด การจัดเก็บ การจัดการ ขั้นตอนการทดสอบ และผลลัพธ์ความแม่นยำ ออกแบบมาเพื่อทั้งบุคลากรทางการแพทย์และผู้ที่ควบคุมโรคเบาหวาน
พรีview คู่มือผู้ใช้เครื่องวัดระดับน้ำตาลในเลือด FORA 6 Connect
คู่มือย่อในการใช้เครื่องวัดระดับน้ำตาลในเลือด FORA 6 Connect เพื่อการทดสอบด้วยตนเอง รวมถึงการตั้งค่า การใช้งาน และการเชื่อมต่อแอป
พรีview คำแนะนำ ข้อมูลจำเพาะ และข้อมูลความแม่นยำของแถบทดสอบ FORA 6
คู่มือครอบคลุมสำหรับแถบทดสอบระดับน้ำตาลในเลือด ฮีมาโตคริต และฮีโมโกลบิน FORA 6 ครอบคลุมถึงการใช้งานตามจุดประสงค์ คำเตือน ข้อจำกัด การจัดเก็บ ขั้นตอนการทดสอบ ผลความแม่นยำ และค่าอ้างอิง