1. บทนำ
This manual provides essential information for the safe and proper installation, operation, and maintenance of the Eaton Cutler-Hammer CHB120 1-Pole 20A Circuit Breaker. This device is designed to protect electrical circuits from overcurrents and short circuits, ensuring the safety of your electrical system and connected equipment. Please read this manual thoroughly before any installation or operation.
2. ข้อมูลด้านความปลอดภัย
คำเตือน: Electrical shock hazard. Improper installation or maintenance can result in serious injury or death. All work on electrical systems should be performed by qualified personnel only. Always disconnect power at the main service panel before working on or near circuit breakers.
- Ensure all power is OFF before installation or servicing.
- ใช้อุปกรณ์ป้องกันภัยส่วนบุคคล (PPE) ที่เหมาะสม
- ตรวจสอบฉบับที่tage and current ratings match your application.
- Do not use damaged circuit breakers.
- ปฏิบัติตามกฎหมายไฟฟ้าในท้องถิ่นและระดับชาติทั้งหมด
3. คุณสมบัติของผลิตภัณฑ์
- แบบอย่าง: CHB120
- โปแลนด์: 1 เสา
- เล่มที่tagอี คะแนน: 120 / 240 โวลต์
- คะแนนปัจจุบัน: 20 Amp
- คะแนนขัดจังหวะ: 10kA@120V
- พิมพ์: เบรกเกอร์มาตรฐาน
- การติดตั้ง: แผงยึด
4. ข้อมูลจำเพาะ
| ข้อมูลจำเพาะ | ค่า |
|---|---|
| ยี่ห้อ | อีตัน |
| หมายเลขรุ่น | CHB120 |
| คะแนนปัจจุบัน | 20 Amps |
| เล่มที่tage เรตติ้ง | 120/240 โวลต์ |
| จำนวนเสา | 1 |
| ประเภทเบรกเกอร์ | มาตรฐาน |
| ประเภทการติดตั้ง | แผงยึด |
| ขัดจังหวะการให้คะแนน | 10kA@120V |
| ขนาดสินค้า | ขนาด 7 x 7 x 7 นิ้ว (โดยประมาณ) |
| น้ำหนักสินค้า | 7 ปอนด์ (โดยประมาณ) |
| ยูพีซี | 704798904778 |
5. การติดตั้ง
Installation of circuit breakers should only be performed by a qualified electrician in accordance with all applicable electrical codes and standards. The following steps are for informational purposes only and do not substitute for professional expertise.
- ตัดการเชื่อมต่อไฟฟ้า: ปิดสวิตช์ไฟหลักที่แผงควบคุมไฟฟ้า ณ มิเตอร์ไฟฟ้าหรือสวิตช์ตัดไฟหลัก ตรวจสอบให้แน่ใจว่าไฟดับแล้วโดยใช้เครื่องวัดแรงดันไฟฟ้าtagอีผู้ทดสอบ
- Remove Panel Cover: Carefully remove the cover of the electrical panel.
- ระบุช่อง: Locate an available slot on the bus bar for the 1-pole CHB120 circuit breaker.
- ติดตั้งเบรกเกอร์: Hook the rear of the circuit breaker onto the retaining clip on the panel's bus bar. Press the front of the breaker firmly until it snaps into place.
- การเชื่อมต่อสายไฟ: Connect the circuit wire (hot wire) to the terminal screw on the circuit breaker. Ensure the wire is properly stripped and the screw is tightened to the manufacturer's specified torque.
- Replace Panel Cover: เมื่อเชื่อมต่อทุกอย่างแน่นหนาและได้รับการตรวจสอบแล้ว ให้ปิดฝาครอบแผงควบคุมไฟฟ้า
- คืนค่าพลัง: เปิดแหล่งจ่ายไฟหลักอีกครั้ง

Figure 1: Eaton Cutler-Hammer CHB120 1-Pole 20A Circuit Breaker. This image displays the Eaton Cutler-Hammer CHB120 circuit breaker, a single-pole device with a 20 Amp rating. It features a white toggle switch for ON/OFF/TRIPPED states and screw terminals for electrical connections. The model number 'CHB120' is visible on the label.
6. การดำเนินการ
The CHB120 circuit breaker has three primary positions for its toggle switch:
- บน: The circuit is energized, and power is flowing. The toggle is typically pushed fully towards the "ON" marking.
- ปิด: The circuit is de-energized, and power is interrupted. The toggle is typically pushed fully towards the "OFF" marking.
- สะดุดล้ม: When an overcurrent or short circuit occurs, the breaker automatically trips to protect the circuit. The toggle will move to an intermediate position, usually between ON and OFF. To reset a tripped breaker, first push the toggle firmly to the full OFF position, then push it to the full ON position.
7. การบำรุงรักษา
โดยทั่วไปแล้วเบรกเกอร์วงจรไฟฟ้าต้องการการบำรุงรักษาเพียงเล็กน้อย อย่างไรก็ตาม แนะนำให้ตรวจสอบด้วยสายตาเป็นระยะ:
- Inspect for any signs of physical damage, discoloration, or burning.
- Ensure all connections are tight. (คำเตือน: Disconnect power before checking connections).
- Keep the electrical panel area clean and free from obstructions.
8 การแก้ไขปัญหา
If your CHB120 circuit breaker frequently trips, consider the following:
- Overloaded Circuit: The most common cause of tripping. Disconnect some appliances or devices from the circuit to reduce the load.
- ไฟฟ้าลัดวงจร: A direct connection between hot and neutral/ground wires can cause a trip. Inspect wiring and connected devices for damage.
- กระแสไฟฟ้ารั่ว: If current leaks to the ground, it can cause a trip (though this breaker is not a GFCI).
- Faulty Appliance/Device: A malfunctioning appliance connected to the circuit can cause repeated tripping. Unplug devices one by one to identify the culprit.
- Faulty Breaker: In rare cases, the circuit breaker itself may be defective. If all other causes are ruled out, consult a qualified electrician for inspection and potential replacement.
If you are unable to resolve the issue, contact a qualified electrician.
9. การรับประกันและการสนับสนุน
Specific warranty information for the Eaton Cutler-Hammer CHB120 circuit breaker is typically provided at the point of purchase or included with the product packaging. For detailed warranty terms, technical support, or service inquiries, please refer to the official Eaton website or contact Eaton customer service directly.
You can visit the Eaton webเว็บไซต์สำหรับข้อมูลเพิ่มเติม: www.อีตัน.คอม