ปาร์คเกอร์ 201579

คู่มือการใช้งานชุดหน้าแปลนสลักเกลียว Parker 201579

แบบอย่าง: 201579 | ยี่ห้อ: พาร์คเกอร์

1. บทนำ

This manual provides essential instructions for the safe and effective installation, operation, and maintenance of the Parker 201579 Bolt Flange Kit. Adherence to these guidelines is crucial for ensuring the proper function, longevity, and safety of the assembled system. Please read this manual thoroughly before proceeding with any installation or maintenance procedures.

The Parker 201579 Bolt Flange Kit is designed for specific industrial applications requiring secure flange connections. Proper installation is critical to prevent leaks and ensure structural integrity.

2. เนื้อหาบรรจุภัณฑ์

Upon opening the package, verify that all components of the Parker 201579 Bolt Flange Kit are present and undamaged. The kit typically includes the following items:

  • Bolts (threaded fasteners)
  • Nuts (mating fasteners for bolts)
  • Washers (if applicable, for load distribution and vibration dampening)
Parker 201579 Bolt Flange Kit in original packaging

รูปที่ 2.1: The Parker 201579 Bolt Flange Kit as received in its sealed plastic bag, showing the Parker branding and model number label.

Close-up of bolts and nuts from Parker 201579 Bolt Flange Kit

รูปที่ 2.2: ใกล้ชิดยิ่งขึ้น view of the components within the Parker 201579 Bolt Flange Kit, clearly showing the bolts and nuts, which are typically made of galvanized or similarly coated steel for corrosion resistance.

3. การตั้งค่าและการติดตั้ง

Proper installation is paramount for the integrity of the flange connection. Always refer to the specific flange assembly instructions provided by the equipment manufacturer for torque specifications and bolt patterns.

  1. การตระเตรียม: Ensure that the flange surfaces are clean, free from debris, and undamaged. Inspect the bolts, nuts, and washers (if included) for any defects.
  2. การจัดตำแหน่ง: Carefully align the two flanges to be joined, ensuring that the bolt holes are concentric.
  3. ตำแหน่งการวางปะเก็น: If a gasket is required, place it correctly between the flange faces. Ensure it is properly seated and not pinched.
  4. Bolt Insertion: Insert the bolts through the flange holes. If washers are used, place them under the nut and/or bolt head as specified by the application.
  5. Nut Engagement: Hand-tighten the nuts onto the bolts. Ensure sufficient thread engagement.
  6. Torquing Sequence: Follow a star or cross-pattern sequence for tightening the bolts to ensure even compression of the gasket and uniform load distribution across the flange. Tighten in stages (e.g., 30%, 60%, 100% of final torque).
  7. แรงบิดสุดท้าย: Use a calibrated torque wrench to apply the manufacturer's specified torque to each bolt. Do not overtighten, as this can damage the bolts, nuts, or flange, leading to failure.

Safety Note: Always wear appropriate personal protective equipment (PPE) during installation, including gloves and eye protection. Consult relevant safety data sheets and local regulations.

4. ข้อควรพิจารณาในการดำเนินงาน

Once installed, the bolt flange connection is typically static. However, certain operational considerations are important:

  • System Pressure/Temperature: Ensure the installed flange connection is rated for the operating pressure and temperature of the system.
  • การสั่นสะเทือน: In high-vibration environments, periodic checks for bolt loosening may be necessary. Consider using locking washers or thread-locking compounds if specified by the application.
  • ปัจจัยด้านสิ่งแวดล้อม: Protect the connection from corrosive environments if the bolt material is not inherently resistant.

5. การบำรุงรักษา

Regular inspection and maintenance are crucial for the long-term reliability of the flange connection.

  • การตรวจสอบภาพ: Periodically inspect the bolts, nuts, and flange for signs of corrosion, cracks, deformation, or loosening.
  • Retorquing: After initial operation or significant temperature cycles, it may be necessary to retorque the bolts to the specified values. Consult equipment manufacturer guidelines.
  • การทำความสะอาด: Keep the area around the flange connection clean to prevent accumulation of corrosive substances.
  • การทดแทน: If any component (bolt, nut, washer) shows signs of significant wear, damage, or corrosion, replace the entire kit or individual components with identical specifications. Do not reuse damaged fasteners.

6 การแก้ไขปัญหา

Common issues related to bolt flange connections and potential solutions:

  • การรั่วไหล:
    • สาเหตุ: Insufficient torque, improper gasket installation, damaged gasket, damaged flange face, uneven bolt tightening.
    • สารละลาย: Retorque bolts following the correct sequence and torque values. Inspect and replace gasket if necessary. Check flange faces for damage.
  • Loose Bolts:
    • สาเหตุ: Vibration, thermal cycling, improper initial torque.
    • สารละลาย: Retorque bolts. Consider using locking mechanisms (e.g., lock washers, thread-locking compound) if appropriate for the application.
  • การกัดกร่อน:
    • สาเหตุ: Exposure to harsh environments, incompatible materials.
    • สารละลาย: Clean and protect the connection. Replace corroded components. Consider using more corrosion-resistant materials or coatings for future applications if environmental conditions are severe.

7. ข้อมูลจำเพาะ

The Parker 201579 Bolt Flange Kit is manufactured to specific standards. Key details include:

  • หมายเลขรุ่น: 201579
  • ยี่ห้อ: พาร์คเกอร์
  • ผู้ผลิต: ปาร์คเกอร์
  • ASIN: B017TEABYY
  • วันที่เข้าใช้งานครั้งแรก: 23 มกราคม 2018

For detailed dimensions, material composition, and performance ratings, refer to the official Parker product data sheets or contact Parker technical support.

8. ข้อมูลการรับประกัน

Parker products are typically covered by a standard manufacturer's warranty against defects in materials and workmanship. The specific terms and duration of the warranty may vary. Please retain your proof of purchase. For detailed warranty information, including coverage, limitations, and how to make a claim, please refer to the official Parker warranty statement available on their corporate website or contact Parker customer service directly.

9. การสนับสนุนและการติดต่อ

For technical assistance, product inquiries, or support regarding the Parker 201579 Bolt Flange Kit, please contact Parker customer service or your authorized Parker distributor. When contacting support, please have the model number (201579) and any relevant purchase information readily available.

You can typically find contact information on the official Parker webเว็บไซต์: www.parker.com

เอกสารที่เกี่ยวข้อง - 201579

พรีview Parker Mobile Hydraulics: Innovative Products and System Solutions
Discover Parker Hannifin's comprehensive catalog of mobile hydraulic components and system solutions, featuring pumps, motors, valves, cylinders, filtration, and more for enhanced mobile equipment performance and efficiency.
พรีview Parker RAH121 Pilot Operated Relief Valve - Technical Specifications
Comprehensive technical details for the Parker RAH121 Pilot Operated Relief Valve, including its features, specifications, performance curve, dimensions, and ordering information. This spool-type hydraulic valve is designed for high accuracy and durability.
พรีview คู่มือผู้ใช้ Parker NitroFlow Lab: คู่มือเครื่องกำเนิดไนโตรเจน
คู่มือผู้ใช้ฉบับสมบูรณ์สำหรับเครื่องผลิตไนโตรเจน Parker NitroFlow Lab เรียนรู้เกี่ยวกับการติดตั้ง การใช้งาน การบำรุงรักษา ความปลอดภัย และการแก้ไขปัญหาสำหรับระบบผลิตก๊าซขั้นสูงนี้
พรีview เครื่องขยายท่อ Parker Parflange® 170 ECO & WCM สำหรับการเชื่อมต่อแบบ F37
รายละเอียดมากกว่าview เกี่ยวกับเครื่องขยายท่อแบบวงโคจร 37° รุ่น Parker Parflange® 170 ECO และ WCM สำหรับการเชื่อมต่อหน้าแปลน F37 คุณสมบัติ ข้อมูลจำเพาะ การเลือกเครื่องมือ และประโยชน์สำหรับการใช้งานในอุตสาหกรรม
พรีview คู่มืออ้างอิงซอฟต์แวร์ไดรฟ์ความเร็วแปรผัน Parker AC20 ซีรีส์
คู่มืออ้างอิงซอฟต์แวร์ที่ครอบคลุมสำหรับ Parker AC20 Series Variable Speed ​​Drive ซึ่งมีรายละเอียดเกี่ยวกับการกำหนดค่า การทำงาน การเขียนโปรแกรม และการแก้ไขปัญหาสำหรับการใช้งานในอุตสาหกรรม
พรีview คู่มือผลิตภัณฑ์ไดรฟ์ความถี่แปรผัน IP66 ซีรี่ส์ Parker AC10
คู่มือผลิตภัณฑ์นี้ให้ข้อมูลโดยละเอียดเกี่ยวกับการติดตั้ง การใช้งาน การบำรุงรักษา และข้อมูลจำเพาะทางเทคนิคสำหรับ Parker AC10 Series IP66 Variable Frequency Drive (VFD) ตั้งแต่ 0 ถึง 90kW