1. บทนำ
This instruction manual provides essential information for the proper installation, operation, and maintenance of the MSA Safety 801582 Sample Probe Passport Water Stop Filter. This product is designed to prevent water ingress into gas detection equipment, ensuring accurate readings and protecting sensitive internal components. Please read this manual thoroughly before use to ensure safe and effective operation.
2. สินค้าหมดview และส่วนประกอบ
The MSA Safety 801582 Water Stop Filter is a critical accessory for sample probe systems, designed to halt the flow of water and protect connected instruments. Each pack contains 10 individual filters.
รูปที่ 1: A pack of ten MSA Safety 801582 Sample Probe Passport Water Stop Filters. These filters are designed to prevent water from entering gas detection equipment.
Each filter unit consists of a durable plastic housing with inlet and outlet ports, containing a specialized membrane or material that stops water while allowing gas samples to pass through. The compact design facilitates easy integration into existing sampเลอไลน์
รูปที่ 2: รายละเอียด view of a single MSA Safety 801582 Water Stop Filter, showing its clear plastic body and connection ports. The filter is marked with "ADVANTEC JP050AN".
3. การตั้งค่าและการติดตั้ง
Proper installation is crucial for the effective performance of the water stop filter. Follow these steps carefully:
- ระบุจุดเชื่อมต่อ: กำหนดสample line where water ingress is a potential issue. The filter should be installed between the sample probe and the gas detection instrument.
- ตรวจสอบความเข้ากันได้: Verify that the filter's connection ports are compatible with your existing sample tubing. The filter is designed for use with MSA Passport systems.
- Orient Correctly: Observe the flow direction indicated on the filter body (if present) or ensure the filter is positioned to intercept water before it reaches the instrument. Typically, the wider end connects to the sample source, and the narrower end to the instrument.
- การเชื่อมต่อที่ปลอดภัย: เชื่อมต่อ sample tubing securely to both the inlet and outlet ports of the filter. Ensure all connections are tight to prevent leaks, which could compromise sample integrity or filter effectiveness.
- ระบบทดสอบ: After installation, perform a system leak test according to your gas detection equipment's manual to confirm proper sealing and functionality.
Warning: Do not force connections. Incorrect installation can lead to leaks or damage to the filter and connected equipment.
4. คู่มือการใช้งาน
Once installed, the MSA Safety 801582 Water Stop Filter operates passively as part of your sample line. It requires no active user input during normal operation.
- การตรวจสอบอย่างต่อเนื่อง: The filter continuously prevents water from reaching your gas detection sensor while allowing the gas sample to pass through.
- การตรวจสอบภาพ: Periodically inspect the transparent body of the filter for any signs of accumulated water or discoloration, which indicates the filter is performing its function and may require replacement.
- การจำกัดการไหล: A significant accumulation of water or particulate matter within the filter may cause a noticeable restriction in sample flow. This is an indication that the filter needs immediate replacement.
5. การบำรุงรักษา
The MSA Safety 801582 Water Stop Filter is a disposable component and is not designed for cleaning or reuse. Regular inspection and timely replacement are the primary maintenance activities.
- ความถี่ในการตรวจสอบ: Inspect the filter daily or before each use, especially in environments where water exposure is likely.
- การทดแทน: Replace the filter immediately if:
- Water is visible inside the filter housing.
- There is a noticeable reduction in sampไหล
- The filter material appears discolored or damaged.
- The filter has been exposed to a significant amount of moisture.
- การกำจัด: Dispose of used filters according to local regulations for industrial waste.
- พื้นที่จัดเก็บ: Store unused filters in their original packaging in a cool, dry place, away from direct sunlight and extreme temperatures.
6 การแก้ไขปัญหา
| ปัญหา | สาเหตุที่เป็นไปได้ | สารละลาย |
|---|---|---|
| Reduced sample flow to instrument | Filter is clogged with water or particulate matter. | Replace the water stop filter. |
| Water detected in gas detection instrument | Filter is compromised or improperly installed. | Inspect filter for damage. Ensure connections are secure. Replace filter if necessary. |
| Filter appears discolored or damaged | Exposure to harsh chemicals or physical stress. | เปลี่ยนไส้กรองทันที |
7. ข้อมูลจำเพาะ
| คุณสมบัติ | รายละเอียด |
|---|---|
| หมายเลขรุ่น | 801582 |
| ประเภทสินค้า | Sample Probe Passport Water Stop Filter |
| ยี่ห้อ | ความปลอดภัย MSA |
| วัสดุ | Durable Plastic (Filter Body), Stainless Steel (Internal/Connectors - as per manufacturer specifications) |
| ขนาดสินค้า | 3 x 2 x 0.1 inches (approximate, individual filter) |
| น้ำหนักสินค้า | 0.48 ounces (individual filter) |
| จำนวนหน่วย | 1 แพ็คมีแผ่นกรอง 10 ชิ้น |
| การรับรองการทดสอบภายนอก | CE |
| ยูพีซี | 641817010266 |
| ประโยชน์หลัก | Prevents water ingress, reduces PFAS (as per product benefits) |
8. การรับประกันและการสนับสนุน
For specific warranty information regarding the MSA Safety 801582 Sample Probe Passport Water Stop Filter, please refer to the documentation provided with your original purchase or contact MSA Safety directly. As a consumable item, filters typically have a limited warranty against manufacturing defects.
For technical support, product inquiries, or to purchase replacement filters, please visit the official MSA Safety webหรือติดต่อฝ่ายบริการลูกค้า คุณสามารถดูข้อมูลเพิ่มเติมได้ที่ MSA Safety Store on Amazon หรือองค์กรของพวกเขา webเว็บไซต์.