The Myron L DS Conductivity Meter model 512M5 is a portable, hand-held single-range instrument designed for fast, accurate, and on-the-spot measurement of conductivity. It features a scale of 0-5000 micromhos (µMhos) or 0-5000 microsiemens (µS) and incorporates built-in electrodes for maximum protection and durability. This reliable instrument has been field-tested for over 40 years, making it a popular choice for various applications requiring precise conductivity measurements.
ข้อมูลด้านความปลอดภัย
Please read and understand all safety instructions before operating the Myron L 512M5 DS Conductivity Meter. Failure to follow these instructions may result in damage to the instrument or personal injury.
- Do not immerse the entire meter in liquid. Only the electrode portion should be submerged.
- Avoid dropping the instrument or subjecting it to severe impact.
- ห้ามพยายามเปิดมิเตอร์asing beyond battery compartment access, as this may void the warranty and expose internal components.
- Keep the meter away from extreme temperatures and direct sunlight.
- Use only the specified 9-volt battery.
- ทิ้งแบตเตอรี่ตามระเบียบข้อบังคับในท้องถิ่น
ส่วนประกอบและคุณสมบัติ

The Myron L 512M5 DS Conductivity Meter is a compact, robust device. The image displays the meter from an elevated angle, showcasing its main components:
- จอแสดงผลมิเตอร์: A large, easy-to-read analog taut-band meter with a scale from 0 to 5000 micromhos/microsiemens per centimeter.
- Sample Cup/Electrode Well: A white, circular well located on top of the unit, designed to hold the sample liquid for measurement. This well contains the built-in electrodes.
- ที่จับ: A black strap handle for portability.
- Battery Compartment (not visible): Located on the rear or bottom, accessible for 9-volt battery installation.
- Calibration Adjustment (not visible): Typically a small screw or knob for calibration purposes.
การตั้งค่า
1. การติดตั้งแบตเตอรี่
- Locate the battery compartment cover, usually on the rear or bottom of the unit.
- ถอดฝาครอบออก
- Connect a new 9-volt battery to the battery clip, ensuring correct polarity.
- Place the battery into the compartment and replace the cover securely.
- The meter is now powered and ready for use. Battery life is typically over 2000 tests or 1 year.
2. การตรวจสอบเบื้องต้น
Before first use, ensure the meter needle rests at zero when no sample is present. If it does not, refer to the calibration section in the Maintenance chapter.
คำแนะนำการใช้งาน
การวัด
- เตรียมเอสampเลอ: รับรองว่า sample liquid is free of air bubbles and suspended solids.
- เติมเอสample Cup: เทเอสample liquid into the white sample cup/electrode well on top of the meter. Fill it sufficiently to cover the electrodes completely.
- อ่านการวัด: The meter will automatically display the conductivity reading on the analog scale. Allow a few seconds for the reading to stabilize.
- บันทึกการอ่าน: Note down the value indicated by the needle on the scale. The scale is marked in micromhos/microsiemens per centimeter.
- เททิ้งและล้าง: After each measurement, empty the sample cup and rinse it thoroughly with deionized or distilled water to prevent contamination for subsequent readings.
- การชดเชยอุณหภูมิ: The meter automatically compensates for temperature variations from 50° to 160°F (10° to 71°C), ensuring accurate readings across a range of temperatures.
การซ่อมบำรุง
การทำความสะอาดขั้วไฟฟ้า
Regular cleaning of the electrodes is crucial for accurate measurements.
- หลังการใช้งานทุกครั้ง ให้ล้างอุปกรณ์ให้สะอาดample cup and electrodes with clean water.
- If deposits build up, gently clean the electrodes with a soft brush or cotton swab and a mild detergent solution. Rinse thoroughly afterwards.
- Do not use abrasive materials or strong solvents, as these can damage the electrodes.
การสอบเทียบ
While the Myron L 512M5 is designed for stability, periodic calibration with a known standard solution is recommended to ensure continued accuracy.
- Obtain a conductivity standard solution with a known value within the meter's range (e.g., 1000 µS/cm).
- เติม sample cup with the standard solution.
- Locate the calibration adjustment screw (refer to the product diagram or manufacturer's specific instructions if unsure).
- Using a small screwdriver, carefully turn the adjustment screw until the meter needle reads the exact value of the standard solution.
- ล้าง sample cup and electrodes thoroughly after calibration.
การเปลี่ยนแบตเตอรี่
Replace the 9-volt battery when the meter needle becomes sluggish or does not respond correctly. Follow the battery installation steps outlined in the Setup section.
การแก้ไขปัญหา
| ปัญหา | สาเหตุที่เป็นไปได้ | สารละลาย |
|---|---|---|
| Meter does not turn on or needle does not move. | แบตเตอรี่เสียหรือติดตั้งไม่ถูกต้อง | Check battery connection; replace 9-volt battery. |
| การอ่านค่าที่ไม่ถูกต้องหรือไม่สม่ำเสมอ | Dirty electrodes; meter out of calibration; air bubbles in sampเล. | Clean electrodes; calibrate meter with standard solution; ensure sample is free of bubbles. |
| Needle stuck or sluggish. | Low battery; physical damage. | เปลี่ยนแบตเตอรี่ หากปัญหายังคงอยู่ โปรดติดต่อฝ่ายบริการลูกค้า |
| No reading with sampเล. | ไม่เพียงพอample volume; electrodes not fully submerged. | มั่นใจ sample cup is filled adequately to cover electrodes. |
ข้อมูลจำเพาะ
- แบบอย่าง: 512 ล้าน
- ช่วงการวัด: 0-5000 µMhos/µS (micromhos/microsiemens per centimeter)
- การชดเชยอุณหภูมิ: Automatic, from 50° to 160°F (10° to 71°C)
- แหล่งพลังงาน: One 9-volt battery
- อายุการใช้งานแบตเตอรี่: >2000 tests / 1 year
- อ่านออกเสียง: 2½ inch taut-band shock resistant analog meter
- ขนาด (ยาว x กว้าง x สูง): 7.1 x 6.9 x 5.25 นิ้ว
- น้ำหนัก: 1.12 ปอนด์
- สี: สีดำ
- ผู้ผลิต: Myron L
การรับประกันและการสนับสนุน
For specific warranty information and technical support, please refer to the official Myron L Company webหรือติดต่อฝ่ายบริการลูกค้า เก็บใบเสร็จรับเงินไว้เป็นหลักฐานการซื้อสำหรับการเคลมประกัน
Myron L Company Contact Information:
- Webเว็บไซต์: www.myronl.com (อดีตampลิงค์ตรวจสอบผู้ผลิตจริง webงาน)
- บริการลูกค้า: อ้างถึง website for contact numbers and email addresses.