1. บทนำ
This manual provides comprehensive instructions for the proper use, setup, operation, and maintenance of the Casella CEL-246/K1 Digital Logging Integrating Sound Level Meter Type 2 Kit. This device is designed for precise sound level measurements, incorporating Digital Signal Processing (DSP) technology for accurate and reliable data.
The CEL-246/K1 offers a wide measurement range, selectable frequency weightings (A and C), and time responses (Slow, Fast, Impulse). It features a non-decaying maximum hold function and a clear display showing current, highest, and average noise levels, along with a time history trend. Data logging capabilities are available via a USB output port.
2. สิ่งที่รวมอยู่
The Casella CEL-246/K1 Kit includes the following components:
- One (1) Casella CEL-246/K1 Sound Level Meter
- One (1) Acoustic Calibrator
- One (1) Foam Windscreen
- กระเป๋าใส่หนึ่ง (1) ใบ
- One (1) Calibration Certificate
- Three (3) AA Batteries
3. การตั้งค่า
3.1 การติดตั้งแบตเตอรี่
- Locate the battery compartment on the rear of the sound level meter.
- เปิดฝาครอบช่อง
- Insert three (3) AA batteries, ensuring correct polarity (+/-).
- ปิดฝาช่องใส่แบตเตอรี่ให้แน่น
3.2 Attaching the Foam Windscreen
Gently slide the foam windscreen over the microphone at the top of the sound level meter. This helps to reduce wind noise during outdoor measurements.
3.3 การเปิดเครื่องครั้งแรก
Press the power button to turn on the device. The display will illuminate, showing the current measurement mode and readings.

An image showing the Casella CEL-246/K1 Digital Logging Integrating Sound Level Meter. The device is blue and grey, with a display screen showing measurement data and a graph. A black foam windscreen is attached to the top microphone.
4. คู่มือการใช้งาน
4.1 การทำงานพื้นฐาน
The CEL-246/K1 features simple two-button operation for ease of use. Refer to the on-screen prompts and the full user guide for detailed button functions.
4.2 Frequency Weighting
The meter supports two frequency weighting scales:
- การถ่วงน้ำหนักแบบ A: Attenuates lower frequencies to approximate the human ear's response, which is most sensitive between 3000 and 4000 Hz. Use for general noise measurements.
- การถ่วงน้ำหนัก C: Reads all frequencies more uniformly, providing a better response to higher frequencies than A-weighting. Useful for pinpointing problems when A-weighted readings are very high.
4.3 Time Weighting
Selectable time responses include:
- ช้า: Provides a slower response, suitable for measuring steady noise levels.
- เร็ว: Offers a quicker response, ideal for capturing fluctuating noise levels.
- แรงกระตุ้น: Designed for very short, sharp noise events.
4.4 Maximum Hold Feature
The non-decaying maximum hold feature captures and displays the highest sound pressure level detected until manually reset. This is useful for identifying peak noise events.
4.5 Data Logging and USB Output
The meter includes a USB output port for simple data logging. Connect the device to a PC to download stored data or for real-time data analysis using the optional software package. Data can be exported in spreadsheet format for further analysis.
4.6 การปรับเทียบอัตโนมัติ
The CEL-246/K1 supports auto calibration at a selected decibel level using the included acoustic calibrator. Refer to the full user guide for detailed calibration procedures to ensure measurement accuracy.
5. การบำรุงรักษา
5.1 การทำความสะอาด
Wipe the meter's exterior with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure no moisture enters the device.
5.2 การเปลี่ยนแบตเตอรี่
Replace batteries when the low battery indicator appears on the display. Always use three (3) new AA batteries of the same type.
5.3 พื้นที่จัดเก็บ
When not in use for extended periods, remove the batteries to prevent leakage. Store the meter in its carrying case in a cool, dry place, away from direct sunlight and extreme temperatures.
5.4 การสอบเทียบ
Regular calibration is crucial for maintaining measurement accuracy. Use the provided acoustic calibrator according to the instructions in Section 4.6 and the full user guide. It is recommended to calibrate the device before each critical measurement session.
6 การแก้ไขปัญหา
6.1 Meter Not Powering On
- Check if the batteries are correctly inserted with proper polarity.
- เปลี่ยนแบตเตอรี่ AA ใหม่
- ตรวจสอบให้แน่ใจว่าได้กดปุ่มเปิด/ปิดอย่างแน่นหนา
6.2 การอ่านค่าที่ไม่ถูกต้อง
- Perform an auto calibration using the acoustic calibrator.
- Ensure the foam windscreen is properly attached to minimize wind noise.
- Verify that the correct frequency (A or C) and time weighting (Slow, Fast, Impulse) are selected for your measurement environment.
- Check for any physical damage to the microphone or device.
6.3 Data Logging Issues
- ตรวจสอบให้แน่ใจว่าได้เสียบสาย USB เข้ากับมิเตอร์และคอมพิวเตอร์อย่างแน่นหนาแล้ว
- Verify that the necessary software drivers are installed on your PC.
- Consult the software manual for specific data transfer instructions.
7. ข้อมูลจำเพาะ
| คุณสมบัติ | ข้อมูลจำเพาะ |
|---|---|
| หมายเลขรุ่น | CEL-246/K1 |
| ช่วงการวัด | 30 ถึง 130 เดซิเบล |
| การถ่วงน้ำหนักความถี่ | A หรือ C |
| เวลาถ่วงน้ำหนัก | Slow, Fast, Impulse |
| แสดง | Current, Highest, Average Noise Level, Time History Trend |
| พอร์ตเอาท์พุท | USB for data logging |
| แหล่งพลังงาน | แบตเตอรี่ AA 3 ก้อน |
| ขนาดแพ็คเกจ | 17 x 12.5 x 4 นิ้ว |
| น้ำหนักแพ็คเกจ | 3.9 ปอนด์ |
| ประเทศต้นกำเนิด | สหราชอาณาจักร |
| ผู้ผลิต | โคล-ปาร์เมอร์ |
8. การรับประกันและการสนับสนุน
For warranty information and technical support, please refer to the documentation provided with your purchase or contact Casella customer service directly. Keep your purchase receipt as proof of purchase.
ผู้ผลิต: โคล-พาร์เมอร์