The Einhell GE-GP 9041 E garden pump is a high-quality, powerful, and intelligent device from the Eco Power series, designed to assist ambitious hobby gardeners in watering their gardens using collected rainwater. This energy-efficient 900-watt pump can deliver up to 4,100 liters of water per hour.

Figure 1: The Einhell GE-GP 9041 E garden pump, showcasing its red and black design with a clear filter housing.
คุณสมบัติหลัก:
- Eco Power Technology: Ensures higher flow rate with reduced power consumption.
- การป้องกันความร้อนเกินพิกัด: Prevents motor overheating during high-performance operation.
- ตัวกรองล่วงหน้าแบบรวม: Protects the pump from impurities in the drawn water.
- Comfortable Carrying Handle: Allows for easy and convenient transport.
- Separate Water Filling Opening: Facilitates easy priming of the pump before use.
- Practical Water Drain Screw: Enables easy draining of residual water for winterization.
- High-Quality Connections: 33.3 mm (1") IG suction and pressure connections made of durable metal for extended lifespan.

Figure 2: The Eco Power logo, indicating efficient technology for higher flow and lower consumption.
การติดตั้งและการตั้งค่า
Proper setup is crucial for the optimal performance and longevity of your Einhell GE-GP 9041 E garden pump. Follow these steps carefully.
1. Positioning the Pump
Place the pump on a stable, level surface, protected from direct weather exposure. Ensure adequate ventilation around the pump.

Figure 3: Detail of the pump's stable base, designed for secure placement.
2. การต่อท่อ
Connect the suction hose to the 33.3 mm (1") IG suction connection and the pressure hose to the 33.3 mm (1") IG pressure connection. Ensure all connections are tight to prevent air leaks, which can affect pump performance.

รูปที่ 4: View of the durable metal suction and pressure connections on the pump.

Figure 5: Another perspective of the robust hose connection point.
3. การปั๊มเบื้องต้น
Before first use or after the pump has been drained, it must be primed. Open the large water filling opening and fill the pump housing completely with water until it overflows. Close the filling opening securely.

Figure 6: Diagram illustrating the large water filling opening for easy priming.
4. Integrated Pre-filter and Non-Return Valve
The pump features an integrated pre-filter and non-return valve. The pre-filter protects the pump from debris, while the non-return valve prevents water from flowing back, maintaining prime. Regularly check and clean the pre-filter to ensure optimal performance.

Figure 7: Close-up of the transparent pre-filter housing, allowing visual inspection of the filter.

Figure 8: Diagram depicting the integrated pre-filter, designed to capture impurities.

Figure 9: Diagram illustrating the function of the non-return valve, preventing backflow.
คำแนะนำการใช้งาน
Once the pump is set up and primed, you can begin operation. Always ensure the pump is connected to a suitable power supply.
1. การสตาร์ทปั๊ม
Plug the power cord into a grounded electrical outlet. Use the ON/OFF switch to start the pump. The pump will begin drawing water and building pressure.

Figure 10: A user demonstrating the Einhell garden pump in action, watering a garden.
2. การตรวจสอบประสิทธิภาพ
The GE-GP 9041 E is designed for continuous operation within its specified limits. The Eco Power technology ensures efficient water delivery. The thermal overload protection will automatically shut off the pump if the motor temperature becomes too high, preventing damage.

Figure 11: Diagram illustrating the internal cooling system of the pump, crucial for preventing overheating.
3. การปิดระบบ
To turn off the pump, simply switch the ON/OFF switch to the OFF position. Disconnect the power cord from the outlet when the pump is not in use for extended periods.
การซ่อมบำรุง
Regular maintenance ensures the longevity and efficient operation of your garden pump.
1. การทำความสะอาดแผ่นกรองชั้นแรก
Periodically inspect the integrated pre-filter for debris. If clogged, remove the filter housing, clean the filter element under running water, and reassemble. Ensure the seal is properly seated to prevent leaks.
2. Winterization (Draining)
Before the first frost, or if the pump will not be used for an extended period in cold conditions, it is essential to drain all residual water to prevent freezing damage. Use the practical water drain screw located at the bottom of the pump to completely empty the unit.

Figure 12: Close-up of the water drain screw, used for emptying the pump for winter storage.
เก็บปั๊มไว้ในที่แห้งและไม่มีน้ำค้างแข็ง
การแก้ไขปัญหา
ส่วนนี้จะนำเสนอวิธีแก้ปัญหาทั่วไปที่คุณอาจพบเจอเกี่ยวกับปั๊มน้ำในสวนของคุณ
| ปัญหา | สาเหตุที่เป็นไปได้ | สารละลาย |
|---|---|---|
| ปั๊มไม่เริ่มทำงาน | No power supply; Thermal overload protection activated; Motor fault. | Check power connection and fuse. Allow pump to cool down if thermal protection activated. Contact service if motor fault suspected. |
| Pump runs but no water is delivered or pressure is low. | Pump not primed; Suction hose leaking air; Suction hose blocked; Water source empty; Pre-filter clogged. | Prime the pump completely. Check all suction hose connections for leaks. Clear any blockages in the suction hose. Ensure water source is sufficient. Clean the pre-filter. |
| Pump stops during operation. | Thermal overload protection activated; Water source empty; Air in pump. | Allow pump to cool down. Check water source. Re-prime the pump. |
| มีเสียงผิดปกติจากปั๊มน้ำ | Air in pump; Debris in pump; Worn bearings. | Re-prime the pump. Check for and remove any debris. Contact service if noise persists. |
ข้อมูลจำเพาะทางเทคนิค
| ข้อมูลจำเพาะ | ค่า |
|---|---|
| ยี่ห้อ | ไอน์เฮลล์ |
| หมายเลขรุ่น | GE-GP 9041 E |
| ผู้ผลิต | ไอน์เฮลล์ |
| แหล่งพลังงาน | สายไฟ |
| เล่มที่tage | 230 โวลต์ |
| วัดtage | 900 วัตต์ |
| อัตราการไหลสูงสุด | 4100 ลิตรต่อชั่วโมง |
| ความสูงสูงสุดของศีรษะ | 48 เมตร |
| ขนาดสินค้า (กว้าง x ยาว x สูง) | 49 x 24 x 30.99 ซม. |
| น้ำหนักสินค้า | 10.9 กิโลกรัม |
| วัสดุ | โลหะ |
| สี | สีแดง |
การรับประกันและการสนับสนุน
For warranty information, technical support, or spare parts, please contact Einhell customer service directly. Keep your purchase receipt and product model number handy when contacting support.
คุณสามารถค้นหาข้อมูลเพิ่มเติมและรายละเอียดการติดต่อได้ที่เว็บไซต์ทางการของ Einhell webไซต์หรือผ่านร้านค้าปลีกในพื้นที่ของคุณ
Note: Specific warranty terms may vary by region. Please refer to the warranty card included with your product or the manufacturer's official webเว็บไซต์เพื่อดูข้อมูลโดยละเอียด