Red Hat EFHC8321G001125/DCDD

Red Hat 1/4" NPT 3-Way Solenoid Valve 125VDC User Manual

Model: EFHC8321G001125/DCDD

การแนะนำ

This manual provides essential information for the safe and effective installation, operation, and maintenance of your Red Hat 1/4" NPT 3-Way Solenoid Valve. This valve is designed for precise control of air/inert gas, light oil, and water flow in various industrial and scientific applications. Please read this manual thoroughly before installation and operation.

ข้อมูลด้านความปลอดภัย

ปฏิบัติตามข้อควรระวังด้านความปลอดภัยต่อไปนี้เสมอเพื่อป้องกันการบาดเจ็บหรือความเสียหายต่ออุปกรณ์:

สินค้าเกินview

The Red Hat 1/4" NPT 3-Way Solenoid Valve features a durable brass body and is designed for normally closed operation. It includes a solenoid coil for electrical actuation and NPT threaded ports for connection to piping systems.

Red Hat 1/4 inch NPT 3-Way Solenoid Valve with brass body and green solenoid coil

Figure 1: Red Hat 1/4" NPT 3-Way Solenoid Valve. This image shows the brass valve body with three threaded ports and the green solenoid coil assembly on top, featuring a red manual override button and electrical wiring.

ข้อมูลจำเพาะ

คุณลักษณะค่า
วัสดุตัวเครื่องทองเหลือง
สื่อมวลชนAir/Inert Gas, Light Oil, Water
การกำหนดค่า3-Way/2-Position, Normally Closed
ขนาดท่อ1/4 In. NPT
เส้นผ่านศูนย์กลางปาก9/32 นิ้ว
Coefficient of Volume (Cv)0.80
Min. Operating Pressure Differential10 ปอนด์ต่อตารางนิ้ว
Max. Operating Pressure Differential (Air/Inert Gas)200 ปอนด์ต่อตารางนิ้ว
Max. Operating Pressure Differential (Light Oil)200 ปอนด์ต่อตารางนิ้ว
Max. Operating Pressure Differential (Water)200 ปอนด์ต่อตารางนิ้ว
Coil Insulation ClassH
คะแนน NEMA3, 3S, 4, 4X, 6, 6P, 7, 9
สูงสุด อุณหภูมิของของไหล120 องศา F
เล่มที่tage125VDC
ผู้ผลิตREDHAT
หมายเลขชิ้นส่วนEFHC8321G001125/DCDD
ยูพีซี696504961345

การติดตั้งและการตั้งค่า

ปฏิบัติตามขั้นตอนเหล่านี้เพื่อการติดตั้งที่ถูกต้อง:

  1. การเตรียมระบบ: Ensure the system is depressurized and drained before installation. Clean all piping and fittings to prevent debris from entering the valve.
  2. การติดตั้ง: Mount the valve in a location that allows for easy access for maintenance and inspection. The valve can be mounted in any position without affecting operation, but mounting with the solenoid upright is generally preferred to extend life.
  3. การเชื่อมต่อท่อ: Connect the piping to the valve's NPT ports. Use a suitable thread sealant (e.g., PTFE tape or pipe dope) on the male threads. Do not overtighten connections, as this can damage the valve body. Ensure the flow direction matches the valve's design (if applicable, though for 3-way, ports are typically marked).
  4. สายไฟฟ้า: Connect the 125VDC power supply to the solenoid coil terminals. Ensure wiring conforms to all local electrical codes. Verify the voltage matches the coil's rating (125VDC).
  5. ตรวจสอบรอยรั่ว: After installation, slowly pressurize the system and check all connections for leaks using an appropriate leak detection method.

คำแนะนำการใช้งาน

The Red Hat 3-Way Solenoid Valve is a normally closed (NC) valve. This means:

To operate, simply apply or remove the specified DC voltage to the solenoid coil as required by your control system.

การซ่อมบำรุง

Regular maintenance ensures optimal performance and extends the life of your solenoid valve. Always depressurize and disconnect power before performing any maintenance.

การแก้ไขปัญหา

ปัญหาสาเหตุที่เป็นไปได้สารละลาย
Valve does not open/closeNo power to coil; Incorrect voltage; Damaged coil; Obstruction in valve; Low pressure differentialCheck power supply and wiring; Verify voltage matches coil rating; Replace coil; Clean valve internals; Ensure minimum pressure differential is met
Valve leaks externallyLoose connections; Damaged body or sealsTighten connections (do not overtighten); Inspect and replace damaged seals or valve body
Valve leaks internally (passing fluid)Worn seals; Debris lodged in valve seatReplace internal seals; Disassemble and clean valve internals
Excessive coil heatปริมาตรไม่ถูกต้องtage; Continuous duty cycle not intended for coil; High ambient temperatureตรวจสอบเล่มที่ถูกต้องtage; Ensure coil is rated for continuous duty if required; Improve ventilation around valve

การรับประกันและการสนับสนุน

For information regarding warranty coverage, technical support, or replacement parts, please contact Red Hat customer service or refer to the official Red Hat website. Keep your purchase receipt and product model number handy when contacting support.

เอกสารที่เกี่ยวข้อง - EFHC8321G001125/DCDD

พรีview Sloan ROYAL 603-3.5-RB-12-3/4-LDIM-L3 Concealed Manual Flushometer Specifications
Detailed specifications, features, and installation information for the Sloan ROYAL 603-3.5-RB-12-3/4-LDIM-L3 manual specialty water closet flushometer. Includes rough brass finish, 3.5 gpf, and concealed design.
พรีview Lab Scientific Pipette Filler 3 Valve User Manual - Product 550.001.270
User manual for the Lab Scientific Pipette Filler 3 Valve (Product Code: 550.001.270). This document provides specifications and detailed operating instructions for the red rubber pipette filler, including how to evacuate, intake, drain, and blow out pipettes using its three valves (A, S, E).
พรีview คู่มือการใช้งานวาล์วน้ำอัจฉริยะ PNI SV200 WiFi
คู่มือผู้ใช้และข้อมูลจำเพาะทางเทคนิคสำหรับวาล์วน้ำอัจฉริยะ PNI SV200 WiFi ซึ่งให้รายละเอียดเกี่ยวกับการติดตั้ง การเชื่อมต่อกับแอป Tuya Smart และข้อมูลการปฏิบัติตามข้อกำหนด
พรีview ซีรีส์ MP1-HC และ MP2 ระเบิด View และรายการอะไหล่
ระเบิดรายละเอียด view แผนผังและรายการชิ้นส่วนที่ครอบคลุมสำหรับหน่วยทำความเย็นซีรีส์ MP1-HC และ MP2 รวมถึงหมายเลขชิ้นส่วนและคำอธิบาย
พรีview AXOR ShowerSolutions Thermostat Module Select 530/90 for 3 Users - Polished Red Gold
Detailed information on the AXOR ShowerSolutions Thermostat Module Select 530/90, featuring a Polished Red Gold finish. This module supports three users simultaneously, offers comfortable Select button control for switching between functions, and includes features like a safety lock at 40°C and adjustable temperature limitation. The document includes technical specifications, installation examples, and a comprehensive spare parts list.
พรีview คู่มือเริ่มต้นใช้งานด่วนชุดจับคู่ฮาร์ดไวร์ JOOVV - การตั้งค่าอุปกรณ์หลายเครื่อง
คู่มือเริ่มต้นใช้งานฉบับย่อสำหรับการตั้งค่าชุดจับคู่ JOOVV Hardwire เพื่อเชื่อมต่ออุปกรณ์บำบัดด้วยแสงสีแดง JOOVV หลายเครื่อง ครอบคลุมรุ่น Half Max, Duo, Max, Quad และ Elite พร้อมคำแนะนำทีละขั้นตอนและไดอะแกรมการกำหนดค่า