การแนะนำ
The KING HWP120 is an advanced electronic line voltage programmable thermostat designed specifically for hydronic heating systems. This thermostat offers precise temperature control and energy savings through its 7-day independent programming capabilities, allowing for up to four time and temperature settings per day. Its user-friendly design features an illuminated LCD display and simple two-button operation for setting temperature and navigating menus. The HWP120 is equipped with memory backup to retain settings during power outages, ensuring consistent comfort.

รูปที่ 1: มุม view of the KING HWP120 Electronic Line Voltage Programmable Hydronic System Thermostat, showing its white casing and green illuminated LCD display.
ข้อมูลด้านความปลอดภัย
คำเตือน: To prevent electric shock or damage to the thermostat, disconnect power to the heating system at the main fuse or circuit breaker box before installation or servicing. This thermostat operates on line voltage (120V/240V) and requires careful handling. Installation should only be performed by a qualified electrician in accordance with local electrical codes.
- Always turn off power at the circuit breaker before working with electrical wiring.
- ตรวจสอบให้แน่ใจว่าการเชื่อมต่อสายไฟทั้งหมดแน่นหนาและมีฉนวนอย่างเหมาะสม
- Do not exceed the specified electrical ratings of the thermostat (12.5 amps / 120 volts, 3000 watts / 240 volts).
- ควรวางเทอร์โมสตัทให้ห่างจากน้ำและความชื้นสูง
การติดตั้งและการตั้งค่า
Proper installation is crucial for the safe and efficient operation of your HWP120 thermostat. It is recommended that a licensed electrician perform the installation.
ตำแหน่งการติดตั้ง
Choose a location on an interior wall, approximately 5 feet (1.5 meters) above the floor, away from direct sunlight, drafts, or heat sources (e.g., lamps, appliances, fireplaces). These factors can affect the thermostat's temperature readings.
คำแนะนำในการเดินสายไฟ
- ตัดการเชื่อมต่อไฟฟ้า: Turn off the power to your heating system at the main circuit breaker. Verify power is off before proceeding.
- ลบเทอร์โมสตัทเก่า: ถอดเทอร์โมสตัทตัวเดิมออกจากผนังอย่างระมัดระวัง โปรดสังเกตการเชื่อมต่อสายไฟด้วย
- การเชื่อมต่อสายไฟ: Connect the wires from your heating system to the appropriate terminals on the HWP120 thermostat. Refer to the wiring diagram provided with your thermostat's packaging for specific connections. Ensure all connections are tight.
- เทอร์โมสตัทแบบติดตั้ง: Secure the HWP120 thermostat to the wall using the provided mounting screws.
- คืนค่าพลัง: เมื่อการติดตั้งเสร็จสมบูรณ์และการเชื่อมต่อทั้งหมดปลอดภัยแล้ว ให้จ่ายไฟอีกครั้งที่เบรกเกอร์

รูปที่ 2 : ด้านหน้า view of the KING HWP120 Thermostat, highlighting the LCD display and the two control buttons below it.
คำแนะนำการใช้งาน
The HWP120 thermostat is designed for straightforward operation using its two primary buttons and illuminated LCD display.
แสดงผลเกินview
The LCD display shows the current room temperature, the set temperature, the time, day of the week, and the active program period (P1, P2, P3, P4). When the heating system is active, a "HEAT" indicator will typically be visible.

รูปที่ 3: มุมด้านข้าง view of the KING HWP120 Thermostat, showing the ventilation grilles on the side and the clear display.
Adjusting Temperature Manually
To temporarily adjust the temperature, press the Up (▲) หรือ ลง (▼) buttons. The display will show the new set temperature. This manual override will typically remain active until the next programmed period begins.
การตั้งเวลาและวัน
Refer to the detailed programming section for initial setup of time and day, as these are integral to the programming functions.
คำแนะนำการเขียนโปรแกรม
The HWP120 allows for 7 independent day programming with 4 times and temperature settings (P1, P2, P3, P4) per day. This feature helps optimize energy consumption by adjusting heating based on your schedule.
เข้าสู่โหมดการเขียนโปรแกรม
To enter programming mode, press and hold both the Up (▲) และ ลง (▼) buttons simultaneously for a few seconds until the display changes to indicate programming mode (e.g., flashing time or day).
การตั้งเวลาและวัน
- In programming mode, the hour will typically flash. Use the Up or ลง ปุ่มเพื่อปรับชั่วโมง
- Press one of the buttons (e.g., Up or ลง, depending on the model's specific navigation) to advance to minutes, then adjust.
- Continue to advance to set the day of the week.
Setting Program Periods (P1-P4)
For each day of the week, you can set four distinct periods:
- P1 (Wake): Typically for morning, when you wake up.
- P2 (Leave): For when you leave home.
- P3 (Return): For when you return home.
- P4 (Sleep): For nighttime.
- While in programming mode, navigate to the desired day (e.g., Monday).
- Select P1. Set the desired start time and temperature for P1 using the Up or ลง ปุ่ม
- Advance to P2 and repeat the process for its start time and temperature.
- Continue for P3 and P4.
- Repeat this process for each day of the week (Tuesday through Sunday).
- การออกจากโหมดการเขียนโปรแกรม: Once all settings are complete, the thermostat will typically exit programming mode automatically after a period of inactivity, or you may need to press and hold the buttons again to save and exit. Consult the full manual for specific exit procedures.
หมายเหตุสำคัญ: The HWP120 thermostat initiates heating at the programmed time to reach the set temperature. It does not anticipate heating. Therefore, if you desire a room to be at a specific temperature by a certain time, set the program to begin heating approximately 15-30 minutes prior to that desired time, depending on your system's response time.
การซ่อมบำรุง
The KING HWP120 thermostat requires minimal maintenance to ensure optimal performance.
- การทำความสะอาด: ควรเช็ดทำความสะอาดภายนอกของเทอร์โมสตัทเป็นระยะด้วยผ้าเนื้อนุ่มและแห้งamp ผ้า ห้ามใช้น้ำยาทำความสะอาดที่มีฤทธิ์กัดกร่อนหรือตัวทำละลาย เพราะอาจทำให้พื้นผิวหรือส่วนประกอบภายในเสียหายได้
- การกำจัดฝุ่น: Ensure the ventilation slots on the thermostat casing remain clear of dust and debris to allow for proper air circulation and accurate temperature sensing.
- พลัง Outage: The thermostat features memory backup for power outages, retaining your programmed settings. No action is typically required after a power restoration.
การแก้ไขปัญหา
If you encounter issues with your HWP120 thermostat, refer to the following common problems and solutions:
| ปัญหา | สาเหตุที่เป็นไปได้ | สารละลาย |
|---|---|---|
| จอแสดงผลเทอร์โมสตัทว่างเปล่า | ไม่มีไฟเข้าเทอร์โมสตัท | Check the circuit breaker for your heating system. Ensure it is in the "ON" position. Verify wiring connections. |
| Heating system not turning on/off as programmed. | Incorrect programming; manual override active; system malfunction. | Review your program settings carefully. Ensure no manual override is active. Check your heating system for other issues. |
| Room temperature inaccurate. | ตำแหน่งเทอร์โมสตัทที่ได้รับผลกระทบจากลมโกรกหรือแหล่งความร้อน | Ensure the thermostat is not exposed to direct sunlight, drafts from windows/doors, or heat from appliances. |
| ความยากลำบากในการเขียนโปรแกรม | Unfamiliarity with programming sequence. | Carefully re-read the "Programming Instructions" section. Practice the steps without making permanent changes. |
If problems persist after attempting these solutions, contact a qualified electrician or KING customer support for assistance.
ข้อมูลจำเพาะ
| คุณสมบัติ | รายละเอียด |
|---|---|
| ชื่อรุ่น | เอชดับบลิวพี120 |
| ยี่ห้อ | กษัตริย์ |
| เล่มที่tage | 120 โวลต์ / 240 โวลต์ |
| Ampอีเรจ | 12.5 ampวินาที (120V) / 12.5 ampเอส (240V) |
| วัดtage | 1500 วัตต์ (120 โวลต์) / 3000 วัตต์ (240 โวลต์) |
| ช่วงอุณหภูมิ | 44°F ถึง 95°F (7°C ถึง 35°C) |
| ความแม่นยำ | ± 1.2°F @ 10 amps, ± .9°F @ 4.2 amps |
| การเขียนโปรแกรม | 7 independent day programming with 4 times and temperature settings per day |
| ประเภทจอภาพ | จอ LCD ดิจิทัลแบบมีไฟส่องสว่าง |
| ประเภทการควบคุม | ปุ่มกด |
| วัสดุ | พลาสติก |
| ขนาด (กว้าง x ยาว x สูง) | 4.88 x 3.13 x 2 นิ้ว |
| น้ำหนักสินค้า | 10.4 ออนซ์ |
การรับประกันและการสนับสนุน
ข้อมูลการรับประกัน
The KING HWP120 Electronic Line Voltage Programmable Hydronic System Thermostat comes with a รับประกันจำกัด 1 ปี from the date of purchase. This warranty covers defects in materials and workmanship under normal use. For specific terms and conditions, please refer to the warranty documentation included with your product or visit the manufacturer's official webเว็บไซต์.
การสนับสนุนลูกค้า
For technical assistance, troubleshooting beyond this manual, or warranty claims, please contact KING customer support. You can typically find contact information (phone number, email, or support portal) on the manufacturer's webเว็บไซต์หรือในบรรจุภัณฑ์ของผลิตภัณฑ์
It is recommended to have your product model number (HWP120) and date of purchase available when contacting support.