Diversitech PF-KIT

คู่มือการใช้งานชุดน้ำยาชะล้าง Diversitech PF-KIT Pro Flush

Model: PF-KIT | Brand: Diversitech

1. บทนำ

This manual provides detailed instructions for the safe and effective use of the Diversitech PF-KIT Pro Flush Flushing Solvent Kit. This kit is specifically designed for cleaning HVAC and refrigeration systems, formulated for applications such as R410A retrofits, refrigerant conversions, and compressor burnouts. It is compatible with all refrigerants and compressor coils, ensuring thorough system cleaning.

2. ข้อมูลด้านความปลอดภัย

WARNING: Improper use of this kit can lead to serious injury or system damage. Always follow safety guidelines.

3. สินค้าหมดview

The Diversitech PF-KIT Pro Flush Flushing Solvent Kit includes the following components:

Diversitech PF-KIT Pro Flush Flushing Solvent Kit components

รูปที่ 1: Diversitech PF-KIT Pro Flush Flushing Solvent Kit. This image displays the main components of the kit, including the PF-16 flushing solvent can, the Pro-Flush injector tool, and the associated hose and adapter.

4. คำแนะนำในการตั้งค่า

  1. เตรียมระบบ: Ensure the HVAC or refrigeration system is depressurized and isolated before beginning the flushing process.
  2. Select Nozzle and Pig: Choose the correct size nozzle and a corresponding foam pig for the line set you intend to clean. The kit includes nozzles from 3/8" to 7/8".
  3. ติดหัวฉีด: Securely attach the selected nozzle to the Pro-Flush injector tool. Tighten the thumb screw on the injector tool until it is thumb-tight.
  4. เติมตัวทำละลาย: Open the chamber of the injector tool. Pour approximately 2 to 3 ounces of PF-16 flushing solvent into the chamber.
  5. Insert Foam Pig: Carefully insert a foam pig into the chamber on top of the solvent.
  6. ห้องปิด: Close the injector tool chamber securely.
  7. Connect Nitrogen Source: Connect the injector tool to a compressed nitrogen source. It is recommended to use a pressure of 70 PSI.
  8. Prepare Catch Bag: Position the catch bag at the exit point of the line set to collect the expelled pig, solvent, and contaminants.

5. คู่มือการใช้งาน

Once the kit is set up and connected, proceed with the flushing operation:

  1. เริ่มการล้างข้อมูล: Firmly pull and hold the trigger on the Pro-Flush injector tool. The compressed nitrogen will propel the foam pig and solvent through the line set.
  2. Observe Pig Exit: Monitor the exit point of the line set for the foam pig to emerge into the catch bag. The pig acts like a squeegee, pushing oils, contaminants, and the flushing solvent out of the line.
  3. ทำซ้ำหากจำเป็น: For heavily contaminated lines, you may need to repeat the process with a fresh foam pig and additional solvent until the expelled pig and solvent appear clean.
  4. Nitrogen Purge: After flushing, continue to purge the line set with nitrogen to ensure all solvent residue is removed. The hydrophobic nature of the foam pigs helps to push out all liquids effectively.

1 วิดีโอ: Demonstration of a line set cleaning process. This video illustrates how a foam pig is propelled through a copper line set using a specialized tool, effectively cleaning out contaminants and liquids. The demonstration highlights the tool's ability to navigate bends and thoroughly clean the line.

6. การบำรุงรักษา

Proper maintenance of your Pro Flush kit components ensures longevity and effective performance:

7 การแก้ไขปัญหา

If you encounter issues during the flushing process, consider the following:

8. ข้อมูลจำเพาะ

9. การรับประกันและการสนับสนุน

For specific warranty information or technical support regarding your Diversitech PF-KIT Pro Flush Flushing Solvent Kit, please refer to the product packaging or contact Diversitech customer service directly. Keep your purchase receipt for warranty claims.

เอกสารที่เกี่ยวข้อง - PF-KIT

พรีview คู่มือการติดตั้ง Hef-T-Bracket - 230-B2L
คำแนะนำในการติดตั้งและข้อมูลจำเพาะสำหรับ DiversiTech Hef-T-Bracket 230-B2L ขายึดผนังสำหรับชุดคอนเดนเซอร์เครื่องปรับอากาศ
พรีview คู่มือการติดตั้งขายึดผนัง Diversitech HW-600 สำหรับระบบมินิสปลิต
คู่มือการติดตั้งที่ครอบคลุมสำหรับขาแขวนติดผนัง Diversitech HW-600 ออกแบบมาสำหรับการติดตั้งเครื่องปรับอากาศแบบแยกส่วนขนาดเล็กภายนอกอาคาร ประกอบด้วยรายการชิ้นส่วน คำแนะนำการประกอบ และข้อมูลความปลอดภัยที่สำคัญ
พรีview คู่มือการติดตั้งปั๊มระบายน้ำคอนเดนเสท DiversiTech Plenum-Rated
คู่มือการติดตั้ง การใช้งาน และการบำรุงรักษาอย่างครบถ้วนสำหรับปั๊มระบายน้ำทิ้งแบบ Plenum-Rated รุ่น DiversiTech CP-22LP-P และ CP-22LP-230-P ประกอบด้วยคำเตือนด้านความปลอดภัย ข้อมูลจำเพาะ คำแนะนำการติดตั้งทีละขั้นตอน เคล็ดลับการแก้ไขปัญหา และข้อมูลการรับประกัน
พรีview ระบบขายึดผนังซีรีส์ ACB ของ DiversiTech สำหรับชุดควบแน่นเครื่องปรับอากาศ
ข้อมูลจำเพาะทางเทคนิคและแนวทางการติดตั้งสำหรับระบบขายึดผนังซีรีส์ DiversiTech ACB รวมถึงรุ่น ACB-30, ACB-36, ACB-42 และ ACB-48 ที่ออกแบบมาสำหรับหน่วยควบแน่นเครื่องปรับอากาศ
พรีview ข้อมูลจำเพาะทางเทคนิคและรายการชิ้นส่วนของขาตั้งมินิสปลิต Diversitech QSMS1201
ข้อมูลจำเพาะทางเทคนิค ขนาด และรายการชิ้นส่วนที่ครอบคลุมสำหรับขาตั้ง Diversitech QSMS1201 Mini Split Stand รวมถึงขาตั้งแบบหดและแบบขยาย viewและรายละเอียดการประกอบ
พรีview คู่มือการติดตั้งและการใช้งานปั๊มคอนเดนเสท DiversiTech
คู่มือนี้ให้คำแนะนำโดยละเอียดเกี่ยวกับการติดตั้ง การใช้งาน และการบำรุงรักษาปั๊มระบายน้ำคอนเดนเสทของ DiversiTech (รุ่น CP-22) ครอบคลุมถึงข้อควรระวังด้านความปลอดภัย ข้อมูลจำเพาะ เนื้อหาในบรรจุภัณฑ์ ขั้นตอนการติดตั้งทีละขั้นตอน การแก้ไขปัญหา และข้อมูลการรับประกัน