1. บทนำและผลิตภัณฑ์view
This manual provides essential information for the safe and effective use of the GE SELA36AT0150 Bolt-On Mount Type SEL Molded Case Circuit Breaker. This current-limiting circuit breaker is designed for industrial and commercial applications, providing protection against overcurrents and short circuits.
คุณสมบัติที่สำคัญ ได้แก่:
- Current Limiting Circuit Breaker: Designed to limit the magnitude and duration of short-circuit currents.
- 150 Amps Max | 150 A Rating Plug: Configured for a maximum current of 150 Amps with a corresponding rating plug.
- 3 Pole, 480/600 VAC: Suitable for three-phase alternating current systems up to 600 Volts.
- Spectra RMS Series: Part of the GE Spectra RMS line, known for advanced protection features.
- Bolt-On Mount: Designed for secure bolt-on installation.

รูปที่ 1 : ด้านหน้า view of the GE SELA36AT0150 Circuit Breaker, showing the ON/OFF switch and product labels.
2. ข้อมูลด้านความปลอดภัย
คำเตือน: Installation, maintenance, and troubleshooting of electrical equipment should only be performed by qualified and licensed electricians. Failure to follow these instructions can result in serious injury, death, or property damage.
- Always disconnect power before working on electrical circuits or equipment.
- ควรใช้อุปกรณ์ป้องกันส่วนบุคคล (PPE) ที่เหมาะสม รวมถึงถุงมือกันความร้อนและแว่นตาป้องกันดวงตา
- Verify all connections are secure and properly torqued according to specifications.
- Ensure the circuit breaker's ratings match the system requirements.
3. การตั้งค่าและการติดตั้ง
The GE SELA36AT0150 is a bolt-on mount circuit breaker. Proper installation is crucial for safe and reliable operation.
3.1 การตรวจสอบก่อนการติดตั้ง
- Confirm the circuit breaker's voltage, current, and interrupting ratings are compatible with the electrical system.
- Inspect the circuit breaker for any physical damage. Do not install damaged units.
- ตรวจสอบให้แน่ใจว่าพื้นผิวในการติดตั้งนั้นสะอาด แห้ง และมีโครงสร้างที่แข็งแรง
3.2 คำแนะนำในการติดตั้ง
- De-energize the electrical panel or system where the breaker will be installed. Verify zero voltage ด้วยมัลติมิเตอร์
- Position the circuit breaker in the designated slot or mounting location.
- Secure the breaker using appropriate bolts and hardware for bolt-on mounting. Ensure it is firmly seated.
- Connect the load and line conductors to the appropriate terminals. The breaker includes a set of bottom lugs.
- Refer to the product label for specific wire ranges and torque specifications:
- Wire Range: #12 - 3/0 CU, #12 - 3/0 AL
- Torque: #12-#10: 35 lb-in, #8-#3: 100 lb-in, #2-3/0: 150 lb-in
- ตรวจสอบการเชื่อมต่อทั้งหมดอีกครั้งเพื่อให้แน่ใจว่าแน่นสนิทและมีการหุ้มฉนวนอย่างเหมาะสม

Figure 2: Close-up of the circuit breaker's main label, detailing Cat No., Amp rating, Voltage, Pole configuration, Rating Plug Type, Lug Data, Wire Range, and Torque specifications.

Figure 3: Close-up of the circuit breaker's interrupting rating label, showing RMS Symmetrical Amps at various voltages (240V, 480V, 600V) and international standards.

รูปที่ 4: ด้านหลัง view of the GE SELA36AT0150 Circuit Breaker, showing the bolt-on mounting points and terminal connections.
4. คู่มือการใช้งาน
The GE SELA36AT0150 circuit breaker is designed for simple operation, primarily acting as an ON/OFF switch and an automatic protective device.
4.1 การเปิด/ปิด
- To turn the circuit ON, firmly push the handle to the "ON" position.
- To turn the circuit ปิด, firmly push the handle to the "OFF" position.
4.2 การสะดุดและการรีเซ็ต
If an overcurrent or short circuit condition occurs, the breaker will automatically "trip" to the center position (between ON and OFF) to protect the circuit. To reset a tripped breaker:
- First, move the handle completely to the "OFF" position. This resets the internal mechanism.
- Investigate and resolve the cause of the trip (e.g., overloaded circuit, short circuit).
- Once the issue is resolved, firmly push the handle to the "ON" position to restore power.
- If the breaker immediately trips again, do not attempt to reset it repeatedly. Consult a qualified electrician.
5. การบำรุงรักษา
Circuit breakers generally require minimal maintenance. However, periodic inspection is recommended to ensure continued safe operation.
- การตรวจสอบภาพ: Annually inspect the breaker for signs of physical damage, discoloration, or loose connections.
- การทำความสะอาด: Keep the area around the breaker clean and free of dust and debris. Use a dry, non-conductive cloth for cleaning. Do not use liquids.
- การตรวจสอบการเชื่อมต่อ: Periodically (e.g., every 3-5 years, or as per local codes) have a qualified electrician check the tightness of terminal connections.
- การทดสอบ: For critical applications, periodic testing of the breaker's trip mechanism by a qualified professional may be required.
บันทึก: ห้ามพยายามเปิดหรือซ่อมแซมเบรกเกอร์วงจรไฟฟ้า เนื่องจากไม่มีชิ้นส่วนใดที่ผู้ใช้สามารถซ่อมแซมได้เอง
6 การแก้ไขปัญหา
ส่วนนี้จะกล่าวถึงปัญหาทั่วไปที่คุณอาจพบเจอเกี่ยวกับเบรกเกอร์วงจรไฟฟ้าของคุณ
| ปัญหา | สาเหตุที่เป็นไปได้ | สารละลาย |
|---|---|---|
| เบรกเกอร์สะดุดบ่อย | วงจรไฟฟ้าเกินกำลัง, ไฟฟ้าลัดวงจร, ไฟรั่วลงดิน หรือเครื่องใช้ไฟฟ้าชำรุด | ลดภาระของวงจร ถอดปลั๊กเครื่องใช้ไฟฟ้า ตรวจสอบสายไฟว่ามีรอยชำรุดหรือไม่ หากปัญหายังคงอยู่ ให้ปรึกษาช่างไฟฟ้าที่มีคุณสมบัติเหมาะสม |
| เบรกเกอร์จะไม่รีเซ็ต | Persistent fault (short circuit/overload) or internal breaker damage. | Ensure the handle is pushed fully to "OFF" before attempting to reset. If it still won't reset, do not force it. Call a qualified electrician. |
| ไม่มีไฟฟ้าไปที่วงจร แต่เบรกเกอร์เปิดอยู่ | Loose connection, wiring issue, or internal breaker failure. | This indicates a serious issue. Immediately turn off the breaker and consult a qualified electrician. Do not attempt to diagnose or fix yourself. |
For any issues not covered here, or if troubleshooting steps do not resolve the problem, always contact a qualified and licensed electrician.
7. ข้อมูลจำเพาะ
Detailed technical specifications for the GE SELA36AT0150 Circuit Breaker:
| คุณลักษณะ | ค่า |
|---|---|
| หมายเลขรุ่น | SELA36AT0150 |
| ยี่ห้อ | บริษัท เจเนอรัล อิเล็คทริค |
| คะแนนปัจจุบัน | 150 Amps |
| เล่มที่tage เรตติ้ง | 480 / 600 VAC |
| จำนวนเสา | 3 |
| ประเภทเบรกเกอร์ | Standard, Current Limiting, Molded Case |
| ประเภทการติดตั้ง | สลักบนภูเขา |
| Interrupting Rating @ 240 VAC | 100,000 Amps |
| Interrupting Rating @ 480 VAC | 65,000 Amps |
| Interrupting Rating @ 600 VAC | 25,000 Amps |
| Rating Plug Type | SRPE150A |
| Rating Plug Inst. Adjustable Range | 450-1991 A (Lo to Hi) |
| ขนาดสินค้า (ลึก x กว้าง x สูง) | 4" x 4" x 6.5" (โดยประมาณ) |
| น้ำหนัก | 4.8 ปอนด์ (โดยประมาณ) |
| วันที่พร้อมใช้งานครั้งแรก | 11 ตุลาคม 2012 |
8. การรับประกันและการสนับสนุน
For specific warranty information regarding your GE SELA36AT0150 Circuit Breaker, please refer to the documentation provided at the time of purchase or contact General Electric directly. As a general guideline, electrical components typically come with a manufacturer's warranty covering defects in materials and workmanship.
For technical support, service, or to inquire about replacement parts, please contact General Electric customer service or visit their official webเว็บไซต์. คุณยังสามารถเยี่ยมชม ร้าน GE บน Amazon for more information on GE products.
Always ensure that any work on electrical systems is performed by qualified and licensed professionals.
9. วิดีโอผลิตภัณฑ์อย่างเป็นทางการ
No official product videos from the seller were found for this specific model in the provided data. For general product information or installation guides, please check the manufacturer's official webเว็บไซต์หรือตัวแทนจำหน่ายที่ได้รับอนุญาต