This instruction manual provides essential information for the proper installation, operation, and maintenance of your Nordyne 903110A Furnace Igniter Kit with Plug. Please read this manual thoroughly before attempting any installation or service to ensure safe and efficient use of the product.
คำเตือนด้านความปลอดภัย: The igniter element is extremely fragile. Handle with care. Do not touch the igniter element directly with bare hands as oils can shorten its lifespan. Always disconnect power to the furnace before installation or maintenance.
2. สินค้าหมดview
The Nordyne 903110A Igniter Kit is a replacement igniter designed for various furnace models, including those starting with M1M from Nordyne, Miller, Intertherm, and Broan. It replaces older style spiral igniters and is compatible with part numbers 632313, 632313C, 903110, 903110A, FC047, and F-1022-21.
- ประเภทสินค้า : Auto Part (Furnace Igniter)
- วัสดุ: Heat-Resistant Silicon Nitride for durability and anti-aging properties.
- วงเล็บ: Aluminum Alloy bracket for higher heat resistance and improved power connection.
- ปลั๊ก: Highly engineered plug, tested to OEM standards.

Figure 2.1: The Nordyne 903110A Furnace Igniter Kit, showing the igniter element, wiring, and connector.

รูปที่ 2.2: ตัวปิด view of the igniter element and its mounting bracket.

Figure 2.3: The igniter kit showing the full length of the igniter and its attached wiring.
วิดีโอผลิตภัณฑ์view
วิดีโอ 2.1: จบแล้วview of the 903110A Furnace Hot Surface Ignitor, detailing its features and applications. This video is provided by the seller to demonstrate the product.
3. ความเข้ากันได้
This igniter kit is designed as a direct replacement for the following part numbers and is compatible with furnace models from various brands:
- แทนที่หมายเลขชิ้นส่วน: 632313, 632313C, 903110, 903110A, FC047, F-1022-21, 632666.
- ยี่ห้อที่เข้ากันได้: Nordyne, Miller, Intertherm, Broan, Frigidaire, Maytag, Gibson.
- Specifically designed for furnace models starting with M1M.
4. ข้อมูลด้านความปลอดภัย
Adhering to safety precautions is crucial when working with furnace components. Failure to follow these instructions could result in property damage, personal injury, or death.
- ตัดการเชื่อมต่อไฟฟ้า: Always turn off the electrical power to the furnace at the main service panel before beginning any installation, maintenance, or troubleshooting.
- แหล่งจ่ายก๊าซ: Ensure the gas supply to the furnace is turned off before working on the igniter.
- ส่วนประกอบที่แตกหักง่าย: The igniter element is ceramic and very fragile. Avoid dropping or striking it.
- หลีกเลี่ยงการปนเปื้อน: Do not touch the igniter element with bare hands. Oils from your skin can create hot spots and shorten the igniter's lifespan. Use clean gloves or handle by the ceramic base.
- การติดตั้งโดยมืออาชีพ: If you are not comfortable performing this installation, it is recommended to contact a qualified HVAC technician.
- เครื่องมือที่เหมาะสม: Use appropriate tools for the job to prevent damage to the igniter or furnace components.
5. การตั้งค่าและการติดตั้ง
Follow these steps carefully to replace your furnace igniter. Refer to your furnace's specific service manual for detailed instructions if available.
- เตรียมความพร้อมสำหรับการติดตั้ง:
- Turn off all electrical power to the furnace at the main breaker.
- ปิดการจ่ายแก๊สไปยังเตาเผา
- Locate the igniter within your furnace. It is typically found near the burners.
- ถอดตัวจุดไฟเก่าออก:
- Carefully disconnect the electrical connector from the old igniter.
- Unscrew any mounting screws or clips holding the old igniter in place.
- Gently remove the old igniter, being careful not to damage other components.
- ติดตั้ง Igniter เวอร์ชันใหม่:
- Handle the new igniter by its ceramic base or with clean gloves to avoid touching the silicon nitride element.
- Position the new igniter in the same location and orientation as the old one.
- Secure the igniter with the mounting screws or clips. Ensure it is firmly in place but do not overtighten.
- Connect the electrical plug of the new igniter to the furnace wiring harness. Ensure a secure connection.
- คืนพลังงานและทดสอบ:
- Turn the gas supply back on.
- Restore electrical power to the furnace at the main breaker.
- Initiate a heating cycle on your thermostat to test the new igniter. Observe for proper ignition.
- If the furnace does not ignite or operates abnormally, refer to the Troubleshooting section.
6. คู่มือการใช้งาน
The igniter operates automatically as part of your furnace's ignition sequence. When the thermostat calls for heat, the igniter will glow hot to ignite the gas burners. No direct user interaction is required for the igniter's operation once installed correctly.
- Ensure your thermostat is set to "Heat" mode and the desired temperature is above the current room temperature.
- The furnace control board will initiate the igniter, which will heat up to a high temperature.
- Once sufficiently hot, the gas valve will open, and the gas will ignite from the hot surface of the igniter.
- The igniter will then turn off as the flame sensor confirms successful ignition.
7. การบำรุงรักษา
Regular maintenance helps ensure the longevity and efficient operation of your furnace and its components, including the igniter.
- การตรวจสอบประจำปี: It is recommended to have your furnace inspected annually by a qualified HVAC technician. They can check the igniter for signs of wear or damage.
- การทำความสะอาด: If the igniter appears dirty or coated with residue, it can be gently cleaned with a soft brush. Ensure the furnace is powered off and cooled down before attempting any cleaning. Avoid using abrasive materials or chemicals.
- ตรวจสอบด้วยสายตา: Periodically, visually inspect the igniter for cracks, discoloration, or other signs of degradation. A healthy igniter should glow brightly and consistently.
- Avoid Physical Contact: As mentioned, avoid touching the igniter element directly to prevent contamination.
8 การแก้ไขปัญหา
If your furnace is experiencing issues related to ignition, consult the table below for common problems and potential solutions. Always ensure power and gas are off before inspecting components.
| ปัญหา | สาเหตุที่เป็นไปได้ | สารละลาย |
|---|---|---|
| Igniter does not glow. | No power to furnace, faulty igniter, loose wiring connection, faulty control board. | Check furnace breaker. Verify wiring connections. Test igniter for continuity (if comfortable and knowledgeable). Replace igniter if faulty. Consult HVAC technician for control board issues. |
| Igniter glows but gas does not ignite. | No gas supply, faulty gas valve, dirty burners, faulty flame sensor. | Ensure gas supply is on. Check for gas leaks. Clean burners. Inspect flame sensor for damage or dirt. Consult HVAC technician for gas valve or flame sensor replacement. |
| Igniter glows weakly or intermittently. | Aging igniter, contaminated igniter surface, low voltage. | Replace igniter. Gently clean igniter surface (see Maintenance). Check furnace wiring for proper voltage. |
| เตาเผาทำงานและหยุดทำงานเป็นรอบๆ อย่างรวดเร็ว (การทำงานแบบสั้นๆ) | Could be related to ignition issues, but often other furnace problems (e.g., airflow, thermostat). | Ensure igniter is functioning correctly. Check air filter. Consult HVAC technician for diagnosis. |
If you are unable to resolve the issue after following these steps, it is recommended to contact a qualified HVAC professional for further assistance.
9. ข้อมูลจำเพาะ
| คุณสมบัติ | รายละเอียด |
|---|---|
| ยี่ห้อ | นอร์ไดน์ |
| หมายเลขรุ่น | I903110 (Replaces 903110A) |
| ประเภทสินค้า | Furnace Igniter Kit |
| Igniter Material | Heat-Resistant Silicon Nitride |
| วัสดุยึด | โลหะผสมอลูมิเนียม |
| ประเภทการติดตั้ง | โบลต์-ออน |
| เพศของตัวเชื่อมต่อ | ชาย |
| น้ำหนักสินค้า | 0.1 กิโลกรัม (ประมาณ 3.52 ออนซ์) |
| ขนาดแพ็คเกจ | ประมาณ 5.39 x 3.15 x 2.91 นิ้ว |
| ยูพีซี | 663132151295 |
10. การรับประกันและการสนับสนุน
For specific warranty information regarding your Nordyne 903110A Furnace Igniter Kit, please refer to the documentation provided with your purchase or contact Nordyne customer support directly. Keep your proof of purchase for warranty claims.
If you require technical assistance or have questions not covered in this manual, please contact a qualified HVAC professional or the manufacturer's customer service department.