Leviton 24W49

Leviton Wetguard 15-Amp, 250-Volt Industrial Grade Locking Plug

Model 24W49 Instruction Manual

1. สินค้าหมดview

The Leviton Wetguard 15-Amp, 250-Volt Industrial Grade Locking Plug (Model 24W49) is a robust wiring device designed for demanding industrial environments. This plug features a polarized, grounding, L6-15P configuration with 3 wires, rated for 250V AC and 15 Amps. It is constructed from EPTR rubber material in a yellow color, ensuring water-tight performance and resistance to various harsh conditions. The Wetguard line meets IP67 and NEMA ratings for water ingress protection, offering superior durability and reliability.

Leviton Wetguard 15-Amp, 250-Volt Industrial Grade Locking Plug, Model 24W49

Figure 1: Leviton Wetguard 15-Amp, 250-Volt Industrial Grade Locking Plug (Model 24W49)

2. คุณสมบัติหลัก

  • Industrial Grade Construction: Built to withstand harsh industrial environments.
  • Watertight and Dust-tight: Meets IP67 and NEMA ratings for protection against water and dust ingress.
  • วัสดุที่ทนทาน: Made from EPTR rubber, resistant to water, acids, alkalis, lubricants, cleaners, and solvents.
  • ความต้านทานการกัดกร่อน: Blades, contacts, terminal screws, and wiring clamps are electroless nickel-coated brass.
  • เดินสายไฟง่าย ๆ : Deep wire wells in the wiring module facilitate easier wiring.
  • การตรวจสอบภาพ: Clear housing aids in inspecting for proper wire insertion and connection.
  • การเชื่อมต่อที่ปลอดภัย: Patented compression nut and strain relief system ensure integrity of both the watertight seal and electrical connection.
  • การกำหนดค่า: L6-15P, 2-pole, 3-wire grounding.
  • ใบรับรอง: UL 498, CSA C22.2, NOM 057 approved.

3. ข้อมูลจำเพาะ

ข้อมูลจำเพาะค่า
หมายเลขรุ่น24W49
Ampอีเรจ15 Amps
เล่มที่tage250 โวลต์
รูปแบบปลั๊กType A (L6-15P)
จำนวนสายไฟ3
จำนวนเสา2
การต่อลงดินใช่
วัสดุEPTR Rubber
สีสีเหลือง
Cord Size Compatibility0.234 ถึง 0.687 นิ้ว
ขนาดสินค้า1.44 x 1.3 x 3.54 นิ้ว
น้ำหนักสินค้า3.2 ออนซ์
การรับรองUL 498, CSA C22.2, NOM 057

4. ข้อมูลด้านความปลอดภัย

Always follow local electrical codes and regulations when installing or servicing electrical devices. Improper installation or use can result in serious injury or death. Disconnect power at the circuit breaker or fuse box before working on any electrical wiring.

  • Ensure the power supply is OFF before installation or maintenance.
  • ควรใช้อุปกรณ์ป้องกันส่วนบุคคล (PPE) ที่เหมาะสม เช่น แว่นตานิรภัยและถุงมือกันความร้อน
  • Verify correct wiring polarity and grounding connections.
  • ไม่เกินปริมาตรที่กำหนดtagอีและ amperage ratings of the device.
  • Keep the device clean and free from debris to maintain its watertight integrity.
  • If the device shows signs of damage, discontinue use and replace it immediately.

5. การติดตั้ง

This section outlines the general steps for wiring the Leviton Wetguard Locking Plug. For detailed wiring diagrams and specific instructions, refer to the packaging or consult a qualified electrician.

  1. เตรียมสายเคเบิล: Strip the outer jacket of the cable to the appropriate length, exposing the insulated conductors. Strip the insulation from each conductor.
  2. Disassemble the Plug: Unscrew the compression nut and separate the plug housing components.
  3. เสียบสายเคเบิล: Feed the prepared cable through the compression nut and into the plug housing.
  4. การต่อสายไฟ: Connect the conductors to the appropriate terminal screws. The clear housing allows for visual verification of proper wire insertion. Ensure all connections are tight and secure.
  5. Assemble the Plug: Reassemble the plug housing, ensuring the internal components are correctly aligned. Tighten the compression nut to create a watertight seal and engage the strain relief system.
  6. ตรวจสอบ: Double-check all connections and ensure the plug is securely assembled before restoring power.

6. การดำเนินการ

The Leviton Wetguard Locking Plug is designed for secure and reliable electrical connections in wet or dusty environments. To operate:

  1. เชื่อมต่อ: Align the blades of the locking plug with the corresponding slots on a compatible locking receptacle.
  2. บิดเพื่อล็อค: Insert the plug fully and twist it clockwise until it locks into place. This action creates a secure mechanical and electrical connection, preventing accidental disconnection.
  3. การตัดการเชื่อมต่อ: To disconnect, twist the plug counter-clockwise to unlock, then pull it straight out from the receptacle.

The watertight design ensures safe operation even when exposed to moisture, provided the connection is properly mated and sealed.

7. การบำรุงรักษา

Regular maintenance helps ensure the longevity and safe operation of your Leviton Wetguard Locking Plug.

  • การตรวจสอบเป็นระยะ: Visually inspect the plug and cable for any signs of wear, cuts, cracks, or discoloration. Check for loose connections or corrosion on the blades.
  • การทำความสะอาด: Clean the exterior of the plug with a damp cloth. Avoid using harsh chemicals or abrasive cleaners that could damage the rubber material. Ensure the plug is dry before use.
  • พื้นที่จัดเก็บ: When not in use, store the plug in a clean, dry environment to prevent damage and prolong its lifespan.
  • ความสมบูรณ์ของซีล: Periodically check the integrity of the compression nut and strain relief system to ensure the watertight seal is maintained.

8 การแก้ไขปัญหา

If you encounter issues with your Leviton Wetguard Locking Plug, consider the following common troubleshooting steps:

  • ไม่มีไฟฟ้า:
    • Check the power source (circuit breaker, fuse).
    • Ensure the plug is fully inserted and locked into the receptacle.
    • ตรวจสอบสายเคเบิลสำหรับความเสียหาย
  • การเชื่อมต่อหลวม:
    • Ensure the plug is twisted and locked securely.
    • If the internal wiring feels loose, disconnect power and re-check the terminal screw connections as per installation instructions.
  • น้ำเข้า:
    • Verify that the compression nut is tightly secured.
    • Inspect the rubber housing for any cracks or damage that could compromise the seal.

If the problem persists after attempting these steps, contact Leviton customer support or a qualified electrician.

9. Related Product Information (Video)

วิดีโอต่อไปนี้ให้ข้อมูลโดยรวมview of the Leviton Wetguard line of watertight wiring devices, showcasing their features and applications in various industrial environments. While the video may feature different models within the Wetguard series, the core principles of durability, watertight sealing, and robust construction apply to the 24W49 locking plug.

วิดีโอ: จบแล้วview of Leviton Wetguard Watertight Wiring Devices

10. การรับประกันและการสนับสนุน

The Leviton Wetguard 15-Amp, 250-Volt Industrial Grade Locking Plug (Model 24W49) is backed by a manufacturer's warranty. For specific warranty details, terms, and conditions, please refer to the product packaging or visit the official Leviton webเว็บไซต์.

For technical assistance, product inquiries, or support, please contact Leviton Customer Service:

  • Webเว็บไซต์: www.leviton.com
  • บริการลูกค้า: อ้างถึง webเว็บไซต์สำหรับข้อมูลการติดต่อในแต่ละภูมิภาค

เอกสารที่เกี่ยวข้อง - 24W49

พรีview คู่มือการเลือกสวิตช์ Leviton เกรดเชิงพาณิชย์และอุตสาหกรรม
คู่มือการเลือกที่ครอบคลุมจาก Leviton ที่ให้รายละเอียดเกี่ยวกับสวิตช์เกรดเชิงพาณิชย์และอุตสาหกรรม รวมถึงสวิตช์แบบสลับ Decora Plus, Lev-lok, สวิตช์ป้องกันจุลินทรีย์ และสวิตช์พิเศษ พร้อมรายละเอียดการใช้งานและแผนผังสายไฟ
พรีview คู่มือการติดตั้งและการทดสอบเต้ารับ GFCI ของ Leviton
คู่มือฉบับสมบูรณ์เกี่ยวกับการติดตั้งและทดสอบเต้ารับ GFCI รุ่น Leviton SmartLock Pro รวมถึงคำแนะนำในการเดินสายไฟ ข้อควรระวังด้านความปลอดภัย และเคล็ดลับในการแก้ไขปัญหา
พรีview Leviton EV40P EV Series 40 AMP คู่มือการติดตั้งเครื่องชาร์จแบบเสียบปลั๊ก
คู่มือการติดตั้งสำหรับ Leviton EV40P EV Series 40 AMP เครื่องชาร์จรถยนต์ไฟฟ้าแบบเสียบปลั๊ก ประกอบด้วยคำเตือนด้านความปลอดภัย ข้อมูลจำเพาะ ขั้นตอนการติดตั้ง วิธีการใช้งาน การใช้งานบัตร RFID ข้อความแสดงข้อผิดพลาด การบำรุงรักษา และข้อมูลการรับประกัน
พรีview คู่มือการติดตั้งและการใช้งานเต้ารับ Leviton GFCI พร้อมพอร์ต USB
คู่มือครอบคลุมสำหรับการติดตั้งและการใช้งานเต้ารับ Leviton GFCI ที่มีพอร์ต USB รวมถึงคำแนะนำในการเดินสาย คำเตือนด้านความปลอดภัย ขั้นตอนการทดสอบ และข้อมูลการรับประกัน
พรีview การติดตั้งและทดสอบปลั๊กไฟอัจฉริยะ GFCI ของ Leviton: คู่มือฉบับสมบูรณ์
คำแนะนำทีละขั้นตอนสำหรับการติดตั้งและทดสอบเต้ารับ GFCI อัจฉริยะของ Leviton (รุ่น D2GF1, D2GF2) เรียนรู้เกี่ยวกับฟังก์ชันการทำงานของ GFCI การเดินสายไฟ การแก้ไขปัญหา และข้อควรระวังด้านความปลอดภัย
พรีview คู่มือการติดตั้งตู้ควบคุมไฟฟ้า Leviton
คู่มือการติดตั้งโดยละเอียดสำหรับตู้ควบคุมไฟฟ้า Leviton รุ่น LP2xx, LP3xx, LP4xx และ LP6xx ครอบคลุมหัวข้อความปลอดภัย การถอดช่องเจาะ การติดตั้ง การเดินสายไฟ การติดตั้งเบรกเกอร์วงจรย่อย และการติดตั้งฝาครอบ