The Yellow Jacket 49965 Titan 4-Valve Test and Charging Manifold is a professional-grade tool designed for comprehensive HVAC/R system diagnostics, evacuation, and charging. Its robust construction and advanced features ensure reliable performance for various refrigerant applications, particularly with R-410A.
คุณสมบัติที่สำคัญ ได้แก่:
- Forged Aluminum Alloy Body: Provides lightweight handling combined with durability for repeated use.
- 4-Valve Design: Enables connection to high/low sides, refrigerant tank, and recovery unit or vacuum pump, facilitating diagnostics, evacuation, and charging without the need to switch hoses.
- 3/8 Inch Vacuum Port: Allows for the use of a larger hose, potentially reducing evacuation time by up to 33%.
- ช่องมองระดับน้ำมัน: Offers clear visibility of refrigerant movement and condition during charging and recovery processes.
- Contoured Easy-Grip Handles: Designed for positive control and color-coded for quick identification.
- Heavy Duty Hook: Engineered for secure attachment without pulling out.

The image displays the Yellow Jacket 49965 Titan 4-Valve Manifold. It features two large, color-coded gauges: a blue low-pressure gauge on the left and a red high-pressure gauge on the right. Both gauges show scales for R-410A refrigerant, temperature in degrees Fahrenheit, and pressure in psi. The manifold body is gray, with four yellow-handled valves and multiple brass hose connections. The 'TITAN 4-Valve Manifold' and 'YELLOW JACKET' branding are visible on the central body.
2. การตั้งค่า
Before operating the manifold, ensure all components are securely connected and in good condition.
2.1 การตรวจสอบเบื้องต้น
- Unpack the manifold and inspect for any visible damage.
- Verify that all valves operate smoothly.
- Check that the gauges are securely attached and the glass is intact.
2.2 การเชื่อมต่อท่อ
The 4-valve design allows for flexible connections. Typically, hoses are connected as follows:
- Connect the blue hose to the low-pressure side of the HVAC/R system.
- Connect the red hose to the high-pressure side of the HVAC/R system.
- Connect the yellow hose to the refrigerant tank or charging cylinder.
- Utilize the fourth hose connection (often the 3/8 inch vacuum port) for connection to a vacuum pump for evacuation or a recovery unit, eliminating the need to swap hoses during a service procedure.
2.3 Gauge Interpretation
The manifold features red and blue gauges calibrated for R-410A refrigerant. They display pressure in bar/psi and temperature in degrees Fahrenheit. Familiarize yourself with the scales for accurate readings.
3. คู่มือการใช้งาน
Always follow industry best practices and safety guidelines when working with refrigerants and HVAC/R systems.
3.1 ข้อควรระวังเพื่อความปลอดภัยทั่วไป
- สวมใส่อุปกรณ์ป้องกันส่วนบุคคล (PPE) ที่เหมาะสม รวมถึงแว่นตาและถุงมือเพื่อความปลอดภัย
- ต้องแน่ใจว่ามีการระบายอากาศที่เหมาะสมเมื่อทำงานกับสารทำความเย็น
- Never over-pressurize a system.
- Refer to the system manufacturer's specifications for correct pressure and charge amounts.
3.2 System Evacuation
To evacuate a system:
- Connect the manifold to the system and a vacuum pump via the 3/8 inch vacuum port for efficient evacuation.
- Open all manifold valves to allow the vacuum pump to pull a vacuum on the system.
- Monitor the low-pressure gauge until the desired vacuum level is achieved.
- Close the manifold valves and shut off the vacuum pump. Observe the gauges for any pressure rise, indicating a leak.
3.3 การชาร์จสารทำความเย็น
To charge a system:
- Ensure the system is evacuated and leak-free.
- ต่อสายยางสีเหลืองเข้ากับถังสารทำความเย็น
- Purge air from the yellow hose by slightly opening the tank valve and then cracking the manifold connection.
- Open the appropriate manifold valve (typically the low-side valve for vapor charging, or both for liquid charging with proper precautions) to allow refrigerant into the system.
- Monitor the system pressures on the gauges and observe refrigerant flow through the sight glass.
- Close the manifold valve and refrigerant tank valve once the desired charge is achieved.
3.4 System Testing and Diagnostics
With the manifold connected, you can monitor system pressures to diagnose performance issues. The sight glass aids in observing refrigerant state and oil return.
4. การบำรุงรักษา
Regular maintenance ensures the longevity and accuracy of your manifold.
- การทำความสะอาด: Wipe down the manifold body and gauges with a clean, damp cloth after each use. Avoid harsh chemicals that could damage the gauges or seals.
- การตรวจสอบท่อ: Regularly inspect hoses for cracks, wear, or damage. Replace any compromised hoses immediately to prevent leaks.
- การทำงานของวาล์ว: Periodically check that all valves turn smoothly and seal completely when closed.
- ความแม่นยำของเกจ: While gauges are factory calibrated, professional calibration may be required periodically to ensure continued accuracy. Consult a qualified technician for calibration services.
- พื้นที่จัดเก็บ: Store the manifold in a clean, dry place, preferably in a protective case, to prevent damage.
5 การแก้ไขปัญหา
หัวข้อนี้จะกล่าวถึงปัญหาทั่วไปที่คุณอาจพบเจอ
- การอ่านค่ามาตรวัดไม่แม่นยำ: Ensure gauges are not damaged. Verify proper connection to the system. If persistent, professional calibration may be needed.
- การรั่วไหลของสารทำความเย็น: Check all hose connections for tightness. Inspect hoses and manifold body for visible damage. Use a leak detector to pinpoint the source.
- Valves Not Sealing: Inspect valve seats for debris or damage. If a valve does not seal, it may require servicing or replacement.
6. ข้อมูลจำเพาะ
| ข้อมูลจำเพาะ | รายละเอียด |
|---|---|
| หมายเลขรุ่น | 49965 |
| ยี่ห้อ | เสื้อกันฝนสีเหลือง |
| วัสดุ | อลูมิเนียม, กระจก |
| ประเภทเธรด | 3/8 Inch NPT (National Pipe Thread) |
| ความเข้ากันได้ของสารทำความเย็น | R-410A |
| Gauge Scale | Degrees F, bar/psi |
| ผู้ผลิต | Fotronic Corporation |
| ขนาดแพ็คเกจ | 12.5 x 12 x 5.3 นิ้ว |
| น้ำหนักสินค้า | 6.2 ปอนด์ |
| ยูพีซี | 686800499659 |
7. การรับประกันและการสนับสนุน
For specific warranty information regarding your Yellow Jacket 49965 Titan 4-Valve Test and Charging Manifold, please refer to the documentation provided with your purchase or contact Yellow Jacket directly. Warranty terms typically cover manufacturing defects for a specified period.
For technical support, service, or replacement parts, please contact the manufacturer or an authorized Yellow Jacket distributor. Always provide your model number (49965) when seeking support.