1. บทนำ
This manual provides essential information for the proper installation, operation, and maintenance of the Fire-Lite Alarms BG-12L Dual Action Pull Station with Key Lock. The BG-12L is a non-coded, dual-action manual pull station designed for use with Fire-Lite Alarms fire alarm control panels. Its dual-action mechanism requires two distinct movements to activate, reducing the likelihood of accidental activation. The integrated key lock allows for secure resetting of the device after activation.
2. ข้อมูลด้านความปลอดภัย
คำเตือน: Installation and servicing of this device must be performed by qualified personnel only. Adhere to all local and national electrical codes, fire codes, and regulations. Disconnect all power before installation or maintenance to prevent electrical shock or equipment damage. Failure to follow these instructions may result in property damage, serious injury, or death.
This device is part of a life safety system. Ensure it is installed and maintained correctly to guarantee proper function in an emergency.
3. เนื้อหาบรรจุภัณฑ์
ตรวจสอบว่ามีส่วนประกอบทั้งหมดอยู่ครบเมื่อแกะกล่อง:
- Fire-Lite Alarms BG-12L Dual Action Pull Station
- รีเซ็ตคีย์
- ฮาร์ดแวร์สำหรับติดตั้ง (สกรู, พุก)
4. สินค้าหมดview
The BG-12L features a robust Lexan construction and a clear, visible design for emergency situations.

รูปที่ 4.1 : ด้านหน้า View of BG-12L Pull Station. This image displays the front of the red Fire-Lite Alarms BG-12L pull station. The word 'FIRE' is prominently displayed in white letters at the top. Below this, a black handle is visible with instructions 'PUSH IN PULL DOWN' and directional arrows. A keyhole for resetting the alarm is located on the lower right side of the unit.

รูปที่ 4.2: มุม View of BG-12L Pull Station. This image provides an angled perspective of the red Fire-Lite Alarms BG-12L pull station, highlighting its side profile and overall depth. The 'FIRE' text and the 'PUSH IN PULL DOWN' handle are visible, along with the keyhole for resetting.

รูปที่ 4.3: ย้อนกลับ View พร้อมขั้วต่อสายไฟ This image shows the rear of the red Fire-Lite Alarms BG-12L pull station, revealing the internal components and wiring terminals. Two screw terminals are clearly visible, designed for electrical connections to the fire alarm control panel.
5. การติดตั้งและการตั้งค่า
Professional installation is highly recommended for all fire alarm system components.
5.1 การติดตั้ง
- Select a visible and accessible location, typically near exits, in accordance with local fire codes.
- Mount the pull station securely to a wall or electrical box using the provided mounting hardware. Ensure the unit is level and firmly attached.
5.2 การเดินสายไฟ
The BG-12L utilizes screw terminals for electrical connections. Refer to the fire alarm control panel's documentation for specific wiring diagrams and requirements. Ensure all connections are secure and comply with applicable electrical codes.
- Connect the appropriate circuit wiring to the screw terminals on the back of the pull station (refer to Figure 4.3).
- Verify correct polarity and continuity before restoring power to the system.
6. คู่มือการใช้งาน
6.1 Activating the Alarm
In the event of a fire, follow these steps to activate the alarm:
- PUSH IN: Firmly push the black handle inward.
- PULL DOWN: Once pushed in, pull the handle down completely.
This dual action will activate the fire alarm system. The handle will remain in the down position, and a yellow 'ACTIVATED' stripe may become visible.
6.2 การรีเซ็ตสัญญาณเตือน
To reset the pull station after activation:
- Insert the provided reset key into the keyhole on the lower right side of the unit.
- Turn the key to unlock the front cover.
- Open the front cover. The handle should return to its normal, unactivated position.
- Close the front cover and turn the key to lock it. Ensure the cover is fully closed and secured.
- Reset the fire alarm control panel according to its specific instructions.
7. การบำรุงรักษา
7.1 การตรวจสอบตามปกติ
Visually inspect the pull station monthly to ensure it is:
- Undamaged and free from obstructions.
- Clean and free of dust or debris.
- Securely mounted to the wall.
7.2 การทำความสะอาด
Clean the exterior of the pull station with a soft, damp cloth. Do not use abrasive cleaners or solvents, as these can damage the Lexan construction.
7.3 การทดสอบ
Functional testing of the pull station should be conducted periodically as required by local fire codes and the fire alarm system's maintenance schedule. This testing should only be performed by authorized personnel to avoid false alarms and ensure proper system functionality.
8 การแก้ไขปัญหา
If the Fire-Lite Alarms BG-12L pull station does not function as expected, consider the following:
- Alarm Fails to Activate: Ensure the dual action (push in, then pull down) is performed correctly and completely. Verify wiring connections to the fire alarm control panel.
- Alarm Cannot Be Reset: Confirm the correct reset key is being used and that it is fully inserted and turned. Ensure the front cover is opened and closed properly.
- ความเสียหายทางกายภาพ: If the unit is physically damaged, it must be replaced immediately.
For persistent issues or complex problems, contact a qualified fire alarm technician for diagnosis and repair.
9. ข้อมูลจำเพาะ
| คุณสมบัติ | ข้อมูลจำเพาะ |
|---|---|
| ยี่ห้อ | ไฟ-ไลท์ |
| หมายเลขรุ่น | บีจี-12แอล |
| ขนาด (กว้าง x ยาว x สูง) | 5.5 x 4 x 1.5 นิ้ว |
| น้ำหนักสินค้า | 8 ออนซ์ |
| สี | สีแดง |
| แหล่งพลังงาน | สายไฟ |
| วัสดุก่อสร้าง | เลกซาน |
| ยูพีซี | 783008104016 |
10. การรับประกันและการสนับสนุน
Specific warranty information for the Fire-Lite Alarms BG-12L Dual Action Pull Station is typically provided at the point of purchase or can be obtained directly from Fire-Lite Alarms or an authorized distributor. Please retain your purchase receipt for warranty claims.
For technical support, service, or further inquiries, please contact your authorized Fire-Lite Alarms dealer or installer. They possess the expertise to assist with system-specific questions and troubleshooting.





