1. สินค้าหมดview
The Fluke 179/EDA2 Industrial Electronics Multimeter Combo Kit is a full-featured digital multimeter (DMM) designed for advanced electronic troubleshooting. This kit includes the Fluke 179 True RMS Digital Multimeter with backlight, along with a comprehensive set of probes and accessories, all housed in a durable carrying case.
The Fluke 179 multimeter offers a wide range of measurement functions, adheres to the latest safety standards, and features a large, easy-to-view แสดง.
เนื้อหาชุด:
- Fluke 179 True RMS Digital Multimeter with backlight
- Fluke TL224 Silicone Test Leads
- Fluke TL910 Electronic Test Probes with replacement tips
- Fluke AC280 Heavy Duty Hook Clips
- Fluke 80BK-A Integrated Temperature Probe
- Fluke C35 Durable Carrying Case
- TPAK Magnetic Meter Hanger

2. การตั้งค่า
2.1. การติดตั้งแบตเตอรี่
The Fluke 179 Multimeter requires 4 AA alkaline batteries for operation. These are typically included with the kit. To install or replace batteries, refer to the instructions provided in the quick start guide or the full user manual for your specific model. Generally, this involves opening the battery compartment on the rear of the device, inserting the batteries with correct polarity, and securing the cover.
2.2. การเชื่อมต่อสายทดสอบ
Ensure the multimeter is turned off before connecting or disconnecting test leads. Insert the black test lead into the COM (common) input jack and the red test lead into the appropriate input jack for your desired measurement (e.g., VΩmA for voltage, resistance, or current measurements).

For specialized measurements, use the included accessories:
- Fluke TL224 Silicone Test Leads: Standard leads for general measurements.
- Fluke TL910 Electronic Test Probes with replacement tips: Ideal for precision work on small electronic components.
- Fluke AC280 Heavy Duty Hook Clips: For secure connections to larger terminals or wires.
- Fluke 80BK-A Integrated Temperature Probe: Connect to the appropriate input jacks for temperature measurements.



3. คู่มือการใช้งาน
The Fluke 179 Multimeter offers a variety of measurement functions. Always select the correct function and range before making a measurement to ensure accuracy and safety.
3.1. การวัดพื้นฐาน
- เล่มที่tage (AC/DC): Turn the rotary switch to V~ (AC) or V- (DC). Connect the test leads in parallel with the circuit or component to be measured.
- กระแสไฟฟ้า (AC/DC): Turn the rotary switch to A~ (AC) or A- (DC) or mA/µA. Connect the test leads in series with the circuit. Ensure the correct input jack is used for the expected current level.
- ความต้านทาน (Ω): Turn the rotary switch to Ω. Connect the test leads across the component. Ensure the circuit is de-energized before measuring resistance.
- ความต่อเนื่อง: Turn the rotary switch to the continuity symbol (speaker icon). The meter will beep if a continuous path is detected.
- การทดสอบไดโอด: Turn the rotary switch to the diode symbol. Connect the test leads across the diode to check its forward voltagอีลดลง
3.2. คุณสมบัติขั้นสูง
- Manual and Automatic Ranging: The multimeter can automatically select the appropriate measurement range. For specific applications, manual ranging can be selected.
- การแสดงผลค้างไว้: กดปุ่ม HOLD เพื่อหยุดการอ่านปัจจุบันบนจอแสดงผล
- พักอัตโนมัติ: Automatically holds stable readings on the display.
- Min/Max-Average Recording: Capture minimum, maximum, and average readings over a period, useful for monitoring fluctuating signals.
- Frequency (Hz) and Capacitance (F) Measurements: Select the appropriate function on the rotary switch to measure frequency or capacitance.
- การวัดอุณหภูมิ: Connect the Fluke 80BK-A Integrated Temperature Probe to the multimeter and select the temperature function to measure temperature.


3.3. การสาธิตวิดีโอ
4. การบำรุงรักษา
4.1. การดูแลทั่วไป
To ensure the longevity and accuracy of your Fluke 179 Multimeter, keep it clean and dry. Wipe the case with a damp cloth and mild detergent as needed. Do not use abrasives or solvents. Store the multimeter and its accessories in the provided Fluke C35 Durable Carrying Case when not in use to protect them from dust and physical damage.
4.2. การเปลี่ยนแบตเตอรี่
When the low battery indicator appears on the display, replace the 4 AA alkaline batteries promptly. Always use fresh batteries of the specified type. Refer to the user manual for detailed instructions on safely opening the battery compartment and replacing the batteries.
5 การแก้ไขปัญหา
If you encounter issues with your Fluke 179 Multimeter, consider the following basic troubleshooting steps:
- ไม่มีปัญหาเรื่องจอภาพ/พลังงาน: Check battery levels and ensure they are correctly installed. Replace batteries if necessary.
- การอ่านค่าที่ไม่ถูกต้อง: Verify that the correct function and range are selected for the measurement. Ensure test leads are properly connected and not damaged. Clean the test lead tips if they appear corroded.
- "OL" (Overload) Indication: This indicates that the measured value exceeds the selected range. Switch to a higher range or a different measurement function if applicable.
- การทดสอบความต่อเนื่อง/ไดโอดไม่ทำงาน: Ensure the circuit is de-energized before performing these tests. Check for proper lead connection.
For more complex issues, consult the full Fluke 179 user manual or contact Fluke customer support.
6. ข้อมูลจำเพาะ
| คุณสมบัติ | รายละเอียด |
|---|---|
| หมายเลขรุ่น | FLUKE-179/EDA2 |
| ขนาดสินค้า | 11.54 x 16 x 3.35 นิ้ว |
| น้ำหนักสินค้า | 1.95 ปอนด์ |
| แหล่งพลังงาน | แบตเตอรี่อัลคาไลน์ |
| แบตเตอรี่ที่จำเป็น | แบตเตอรี่ AA 4 ก้อน (รวมอยู่ด้วย) |
| ผู้ผลิต | บริษัท ฟลุ๊ค คอร์ปอเรชั่น |
| สไตล์ | ELECTRONICS DMM AND DELUXE ACCESSORY COMBO KIT |
7. การรับประกันและการสนับสนุน
For warranty information and technical support, please refer to the documentation included with your Fluke 179/EDA2 kit or visit the official Fluke website. Fluke products are known for their reliability and often come with comprehensive support.
คุณสามารถเยี่ยมชม ร้าน Fluke บน Amazon สำหรับรายละเอียดผลิตภัณฑ์เพิ่มเติมและทรัพยากรสนับสนุน