1. บทนำ
This manual provides comprehensive instructions for the safe and effective installation, operation, and maintenance of the Ranco O16-108 Pressure Control Switch. Please read this manual thoroughly before attempting to install or operate the device. Retain this manual for future reference.
2. ข้อมูลด้านความปลอดภัย
คำเตือน: Electrical shock hazard. Disconnect power before installation or servicing. Installation and servicing must be performed by qualified personnel only. Failure to follow these instructions could result in serious injury or death.
- ควรสวมใส่อุปกรณ์ป้องกันส่วนบุคคล (PPE) ที่เหมาะสมเสมอ
- ตรวจสอบให้แน่ใจว่าการเดินสายไฟทั้งหมดเป็นไปตามข้อกำหนดด้านไฟฟ้าของท้องถิ่นและระดับประเทศ
- Do not exceed the specified electrical ratings of the device.
- Verify proper grounding to prevent electrical hazards.
3. สินค้าหมดview
The Ranco O16-108 is a robust pressure control switch designed for industrial applications. It features a durable housing, a clear pressure scale for precise adjustments, and a capillary tube for remote pressure sensing. This device is engineered to provide reliable switching based on detected pressure changes.

รูปที่ 1: Ranco O16-108 Pressure Control Switch. The image displays the main control unit with a visible pressure scale (showing values like 10, 15, 20, 30, 40, 50 in PSI and bar), the Ranco logo, and a capillary tube extending from the bottom, coiled, and terminating in a brass fitting. The scale indicates "CLOSES ON PRESSURE RISE" and "SWITCH LOW EVENT".
4. การตั้งค่าและการติดตั้ง
Proper installation is crucial for the optimal performance and longevity of the Ranco O16-108. Consult a qualified technician for installation if you are not experienced with electrical and pressure systems.
4.1 การติดตั้ง
- Mount the control unit in a location free from excessive vibration, moisture, and extreme temperatures.
- Ensure adequate clearance for wiring and adjustments.
- Use appropriate fasteners to secure the unit firmly to a stable surface.
4.2 Pressure Connection
- Connect the capillary tube's brass fitting to the pressure source.
- Ensure a leak-free connection. Do not bend the capillary tube sharply, as this can damage the sensing element.
- The capillary tube transmits pressure changes to the control unit.
4.3 เดินสายไฟฟ้า
- Refer to the wiring diagram provided with the product (not included in this manual) for specific connections.
- Connect power supply and load wires to the appropriate terminals. The contact type is Normally Open (NO) and the terminal is SPDT (Single Pole Double Throw).
- ตรวจสอบให้แน่ใจว่าการเชื่อมต่อทั้งหมดปลอดภัยและเป็นฉนวน
5. คู่มือการใช้งาน
The Ranco O16-108 operates automatically based on the set pressure points. Adjustments are made via the visible scale on the front of the unit.
5.1 Setting Pressure Points
- Identify the desired cut-in and cut-out pressure values for your application.
- Use a small screwdriver or adjustment tool (if required) to move the indicators on the pressure scale to the desired settings. The scale shows values in both bar and PSI.
- The device is designed to close on pressure rise, meaning the switch will activate when the pressure reaches the set point.
- The "SWITCH LOW EVENT" and "MINUS DIFF" markings on the scale relate to setting the differential pressure.
5.2 Manual Operation / Reset (if applicable)
While the primary operation is automatic, some Ranco pressure controls may feature a manual reset or test button. If present, this button allows for manual activation or resetting of the switch. Consult the specific product labeling for details on any manual functions.
6. การบำรุงรักษา
The Ranco O16-108 is designed for minimal maintenance. Regular inspections are recommended to ensure continued reliable operation.
- การตรวจสอบภาพ: Periodically check the unit for any signs of physical damage, corrosion, or loose connections.
- การทำความสะอาด: Keep the exterior of the control unit clean and free of dust and debris. Use a soft, dry cloth. Do not use abrasive cleaners or solvents.
- หลอดแคปิลลารี: Inspect the capillary tube for kinks, damage, or leaks. Ensure it is securely connected at both ends.
7 การแก้ไขปัญหา
If the Ranco O16-108 is not functioning as expected, review ควรตรวจสอบปัญหาทั่วไปต่อไปนี้ก่อนติดต่อฝ่ายสนับสนุน
- Device not switching:
- ตรวจสอบแหล่งจ่ายไฟให้กับตัวเครื่อง
- ตรวจสอบว่าการเชื่อมต่อสายไฟถูกต้องและปลอดภัย
- Ensure the pressure is within the set operating range.
- Inspect the capillary tube for damage or blockages.
- การอ่านค่าความดันไม่ถูกต้อง:
- Confirm the capillary tube is properly installed and free of leaks.
- Check for external factors affecting pressure sensing (e.g., temperature fluctuations at the sensing point).
- Unit appears damaged:
- Do not attempt to repair internal components. Contact a qualified service technician.
8. ข้อมูลจำเพาะ
| คุณสมบัติ | รายละเอียด |
|---|---|
| ยี่ห้อ | รันโก้ |
| หมายเลขรุ่น | O16-108 |
| ขนาดสินค้า (กว้าง x ยาว x สูง) | 4.25 x 6.5 x 2.5 นิ้ว |
| น้ำหนักสินค้า | 1.3 ปอนด์ |
| หมายเลขหุ้นแห่งชาติ | 5930-00-708-1968 |
| โหมดการทำงาน | ออโต้ |
| ประเภทการติดต่อ | เปิดปกติ |
| ประเภทขั้วต่อ | สกรูเทอร์มินัล |
| เทอร์มินัล | SPDT (ขั้วเดี่ยวสองขั้ว) |
| ประเภทวงจร | 1 ทาง |
| ประเภทตัวกระตุ้น | Push Button (likely for reset/test or internal mechanism) |
| วัสดุติดต่อ | ทองแดง |
| การให้คะแนนการคุ้มครองระหว่างประเทศ | IP00 |
9. การรับประกันและการสนับสนุน
For warranty information, technical support, or service inquiries regarding your Ranco O16-108 Pressure Control Switch, please contact Ranco customer service or your authorized Ranco distributor. Keep your purchase receipt and model number handy when contacting support.
ผู้ผลิต: รันโก้