Coolmay CX3G-24MT

คู่มือการใช้งานคอนโทรลเลอร์ PLC PID Coolmay CX3G-24MT

Model: CX3G-24MT | Brand: Coolmay

1. บทนำ

This manual provides detailed instructions for the installation, operation, programming, and maintenance of the Coolmay CX3G-24MT PID PLC Controller. The CX3G-24MT is a versatile programmable logic controller designed for industrial automation applications, featuring voltage support, high-speed pulse control, and motor drive capabilities. It integrates PID auto-tuning, linear arc interpolation, and supports various communication protocols.

ด้านหน้า view of the Coolmay CX3G-24MT PLC controller

รูปที่ 1 : ด้านหน้า view of the Coolmay CX3G-24MT PLC controller.

2. สินค้าหมดview

The Coolmay CX3G-24MT is a compact and powerful PLC controller offering 12 digital inputs (DI) and 12 digital outputs (DO). It supports multiple communication interfaces including RS232, RS485, and CAN, making it highly adaptable for various control systems. Key features include:

  • Highly integrated I/O, supporting up to 80 points in the CX3G series.
  • Supports up to 16 optional AD analog quantities.
  • 6-channel single-phase high-speed counting.
  • Standard 8-channel high-speed pulse output.
  • Advanced features like interrupt handling, linear arc interpolation, and PID auto-tuning.
  • 32K program capacity and 32K retentive registers.

Video 1: Product showcase highlighting the physical features and ports of the Coolmay CX3G PLC.

Labeled diagram of the CX3G PLC components and ports

Figure 2: Labeled diagram of the CX3G PLC components and ports. Key components include: 1. Mounting hole, 2. Terminal block for input signal of power supply, 3. Terminal block of digital output, 4. LED of Digital Input, 5. LED of Digital Output, 6. PWR: Power-up State (RUN: The light is On when the PLC is run), 7. RS485/RS232/CAN, 8. RS485, 9. RS485, 10. RUN/STOP PLC operational switch, 11. Analog output, 12. RS232, 13. DIN-Rail Slot (35mm), 14. Terminal block of digital input, 15. PLC USB programming port.

Diagram illustrating high-speed counting and pulse capabilities

Figure 3: Diagram illustrating the high-speed counting and high-speed pulse capabilities of the PLC.

3. ข้อมูลจำเพาะ

The following tables detail the specifications for the CX3G series, including the CX3G-24MT model.

3.1 ข้อกำหนดทั่วไป

คุณสมบัติคำอธิบาย
หมายเลขรุ่นCX3G-24MT
ประเภทมอเตอร์DC Motor, AC Motor
สารเคมีที่น่ากังวลสูงไม่มี
ต้นทางจีนแผ่นดินใหญ่

3.2 CX3G Series Model Specifications

Table of specifications for various CX3G models

Figure 4: Detailed specifications for CX3G models including dimensions, I/O, and features.

แบบอย่างCX3G-16MCX3G-24MCX3G-32MCX3G-48MCX3G-34MCX3G-64MCX3G-80M
มิติ85*90*36มม.130*90*36มม.200*90*36มม.285*90*36มม.
ขนาดคัตเอาท์77*99มม.122*99มม.192*99มม.277*99มม.
การติดตั้งFixed hole installation and DIN-Rail (35mm)
คุณสมบัติSupport interrupt, linear arc interpolation, PID auto-tuning. 32K program capacity, 32K retentive register
I/O levelInput: Passive NPN, public terminal isolated
Transistor output: NPN
Relay output: Normally open dry contact
ดิจิทัลไอโอ8DI/8DO12DI/12DO16DI/16DO24DI/24DO18DI/16DO32DI/32DO40DI/40DO
DO typeTransistor(MT) or mixed(2T6R)Relay(MR) or transistor(MT) or mixed(MRT)
(Relay output: max load 5A/ transistor output: max load 500mA)
High speed counting6 channel single-phase 60KHz or AB(Z) phase 2 channel 60KHz, 1 channel 10KHz
High speed pulse8 channels, Y0-Y3 is 100KHz, Y4-Y7 is 10KHz
High-speed counting + high-speed pulse < 480KHz
Analog I/O (optional)โมฆะ6AI/4AO2เอไอ8AI/4AO12AI/8AO16AI/8AO4AI/4AO
AI type (optional)Type E/K/S/T/J thermocouple/ PT100/ PT1000/ NTC10K/ NTC50K/ NTC100K/
0~10V/ 0~5V/ 0-20mA/ 4-20mA
-5V~5V/ -10V~10V (except for CX3G-16M)
AO type (optional)0~10V/ 0-~5V/ 0~20mA/ 4~20mA
-5~5V/ -10~10V (2DA for 1 minus temperature)
Default COM port1 Mini type B USB port, 1 Rs232 (Interface terminal is mouse female port with 8 holes), 2 RS485 ports
ไม่จำเป็นDefault 2 RS485 ports can be customized as:
1 RS485, 1 RS232,
or 1 RS485, 1 CAN (2.0A/B),
or 1 RS232, 1 CAN (2.0A/B)
CX3G-48M can add Ethernet port.
Default 2 RS485 ports can be customized as 1 RS485, 1 RS232,
CAN (2.0A/B) port is optional
ซอฟต์แวร์Compatible with WORKS 2

3.3 Analog Input Types and Ranges

Table detailing analog input types and their corresponding ranges

Figure 5: Detailed analog input types and their corresponding temperature/voltage/current ranges.

พิมพ์คำอธิบาย
PTPT100 (Range: -200~500℃)
PT1000PT1000 (Range: -200~500℃)
EThermocouple type E (Range: 0~600℃)
E_Thermocouple type E, positive and negative temp. test (Range: -110~730℃)
KThermocouple type K, positive temperature test (Range: 0~1100℃)
K_Thermocouple type K, positive and negative temp. test (Range: -230~1370℃)
TThermocouple type T (Range: 0~400℃)
T_Thermocouple type T, positive and negative temp. test (Range: -230~400℃)
SThermocouple type S (Range: 0~1690℃)
S_Thermocouple type S, positive and negative temp. test (Range: -40~1690℃)
JThermocouple type J (Range: 0~800℃)
J_Thermocouple type J, positive and negative tempe. test (Range: -90~950℃)
กทช.10กThermistor 10K (Range: -48~110℃)
กทช.50กThermistor 50K (Range: -48~210℃)
กทช.100กThermistor 100K (Range: -48~210℃)
V0~10โวลต์
V50~5โวลต์
V + customized voltage0~customized voltage (e.g., customized as 0~24V, the model is written as “V24”)
V_-10~10โวลต์
V5_-5~5โวลต์
A00~20มิลลิแอมป์
A44~20มิลลิแอมป์

4. การตั้งค่าและการติดตั้ง

The CX3G-24MT PLC controller can be installed using fixed holes or mounted on a 35mm DIN-Rail. Ensure proper ventilation and a stable environment for installation.

4.1 แผนผังการเดินสายไฟ

Careful wiring is crucial for the correct and safe operation of the PLC. Refer to the diagrams below for connecting the PLC to other devices and for input/output configurations.

Wiring diagram for connecting CX3G PLC and HMI

Figure 6: Wiring diagram for connecting the CX3G PLC and HMI. This diagram illustrates connections for USB-232 serial port cable, PLC download cable, Mini type-B PLC download cable, HMI programming cable, and DC24V power supply.

Detailed input and output wiring diagrams

Figure 7: Detailed wiring diagrams including an input wiring diagram, relay output equivalent circuit diagram, and transistor output equivalent circuit diagram.

4.2 โปรโตคอลการสื่อสาร

The CX3G-24MT supports a variety of communication protocols, enabling integration with different industrial devices.

Diagram showing PLC supporting multiple communication protocols

Figure 8: Diagram showing the PLC supporting multiple communication protocols, including Mitsubishi programming port, Mitsubishi BD board, Modbus RTU/ASCII/TCP, N:N communication, and EIP protocol, and connections to various devices like sensors, relays, thermocouples, soft starters, and frequency converters.

5. คู่มือการใช้งาน

Once the PLC is properly installed and wired, ensure the power supply is stable (DC24V). The 'PWR' LED will illuminate when the PLC is powered on. The 'RUN' LED indicates that the PLC program is actively running. Use the RUN/STOP switch (labeled 10 in Figure 2) to control the PLC's operational state.

6. การเขียนโปรแกรม

The Coolmay CX3G-24MT PLC is compatible with WORKS 2 programming software. You can connect your computer to the PLC via the Mini type B USB port (labeled 15 in Figure 2) or the RS232 port (labeled 12 in Figure 2) for programming and debugging. Software and manuals are available on the Coolmay webเว็บไซต์หรือติดต่อฝ่ายสนับสนุนลูกค้า

7. การบำรุงรักษา

To ensure the longevity and reliable operation of your Coolmay CX3G-24MT PLC controller, follow these maintenance guidelines:

  • รักษาเครื่องให้สะอาดและปราศจากฝุ่นและเศษซาก
  • Regularly check all wiring connections for tightness and signs of wear.
  • Ensure adequate ventilation around the PLC to prevent overheating.
  • Avoid exposing the unit to excessive moisture, extreme temperatures, or corrosive environments.
  • Periodically back up your PLC programs.

8 การแก้ไขปัญหา

If you encounter issues with your CX3G-24MT PLC, consider the following common troubleshooting steps:

  • ไม่มีพลังงาน/ไฟ LED ดับ: Check the DC24V power supply connection and ensure it is providing the correct voltage. Verify the power switch is in the 'ON' position.
  • PLC Not Running: Ensure the RUN/STOP switch is in the 'RUN' position. Check your program for errors using the WORKS 2 software.
  • ปัญหาการสื่อสาร: Verify the correct cable is used (USB or RS232) and that the drivers are installed on your computer. Check communication settings (baud rate, parity, data bits, stop bits) in both the PLC and the programming software. For Modbus communication, ensure the protocol settings are correctly configured.
  • I/O Malfunction: Check wiring to input/output devices. Verify the status of input/output LEDs on the PLC. Test external devices independently to rule out external faults.

9. เคล็ดลับผู้ใช้

  • ซอฟต์แวร์การเขียนโปรแกรม: The PLC is programmed using WORKS 2 software. Ensure you have the latest version for optimal compatibility and features.
  • Modbus Support: This PLC supports Modbus communication. Refer to the programming manual for detailed instructions on configuring Modbus RTU/ASCII/TCP protocols for integration with other devices.
  • อินพุตแบบอะนาล็อก: When using optional analog inputs, ensure the correct sensor type (e.g., PT100, Thermocouple, Voltage, Current) is selected in your program to match your hardware.

10. การรับประกันและการสนับสนุน

For technical support, software downloads, or further assistance, please contact Coolmay customer service. Software and manuals are provided free of charge and can be obtained from the official Coolmay website or by reaching out to the seller.

เอกสารที่เกี่ยวข้อง - CX3G-24MT

พรีview คู่มือผู้ใช้ Coolmay Cloud Platform: การลงทะเบียน การผูก และการกำหนดค่า
คู่มือฉบับสมบูรณ์เกี่ยวกับการใช้แพลตฟอร์ม Coolmay Cloud สำหรับการควบคุม PLC ระยะไกล ครอบคลุมตั้งแต่การลงทะเบียนบัญชี การผูกอุปกรณ์ การกำหนดค่าตัวแปรสเลฟ และการตั้งค่าพารามิเตอร์เครือข่าย เอกสารนี้อธิบายขั้นตอนในการผสานรวม Coolmay PLC เข้ากับระบบคลาวด์เพื่อการตรวจสอบและควบคุมที่มีประสิทธิภาพยิ่งขึ้น
พรีview คู่มือการเขียนโปรแกรม Coolmay PLC V20.81 - คำแนะนำและการใช้งาน
คู่มือการเขียนโปรแกรมที่ครอบคลุมสำหรับคอนโทรลเลอร์ซีรีส์ Coolmay PLC (V20.81) พร้อมรายละเอียดคำแนะนำ การใช้งานอุปกรณ์ และหลักการเขียนโปรแกรม ใช้งานร่วมกับซอฟต์แวร์ Mitsubishi ได้
พรีview คู่มือการใช้งานและการเขียนโปรแกรม Coolmay QM3G Series HMI/PLC All-in-One: คุณสมบัติ ข้อมูลจำเพาะ และคู่มือการใช้งาน
คู่มือการเขียนโปรแกรมฉบับนี้ให้รายละเอียดอย่างครบถ้วนเกี่ยวกับอุปกรณ์ HMI/PLC ออลอินวัน Coolmay QM3G Series ครอบคลุมถึงข้อกำหนดของฮาร์ดแวร์ ข้อควรระวังในการเขียนโปรแกรม ฟังก์ชันการทำงานของ PLC และ HMI โปรโตคอลการสื่อสาร (Modbus, RS485, CAN, Ethernet) และการใช้งานซอฟต์แวร์ ซึ่งให้ข้อมูลที่จำเป็นสำหรับวิศวกรและช่างเทคนิคที่ทำงานกับโซลูชันระบบอัตโนมัติทางอุตสาหกรรมของ Coolmay
พรีview คู่มือการเขียนโปรแกรม PLC Coolmay L02 Series: คุณลักษณะ ข้อมูลจำเพาะ และแอปพลิเคชัน
สำรวจคู่มือการเขียนโปรแกรม PLC Coolmay L02 Series คู่มือนี้ให้รายละเอียดเกี่ยวกับคุณสมบัติขั้นสูงของ PLC L02 สถาปัตยกรรมระบบ ความเข้ากันได้ของโมดูล โปรโตคอลการสื่อสาร (Modbus, Ethernet/IP) และคำแนะนำในการเขียนโปรแกรม เหมาะสำหรับการใช้งานด้านระบบอัตโนมัติและระบบควบคุมในอุตสาหกรรม
พรีview คู่มือผู้ใช้ Coolmay CM-GPRS - โมดูลการสื่อสารไร้สาย
คู่มือผู้ใช้ฉบับสมบูรณ์สำหรับโมดูลสื่อสารไร้สาย Coolmay CM-GPRS ซึ่งประกอบด้วยรายละเอียดเกี่ยวกับฮาร์ดแวร์ โหมดการทำงาน การส่งข้อมูล การระบุตำแหน่ง GPS และการกำหนดค่า รวมถึงข้อมูลเกี่ยวกับรุ่น CM-GPRS-G และ CM-GPRS-L
พรีview คู่มือผู้ใช้ Coolmay CM500 VFD
คู่มือผู้ใช้สำหรับไดรฟ์ความถี่แปรผัน (VFD) Coolmay CM500 ครอบคลุมข้อควรระวังด้านความปลอดภัย ข้อมูลผลิตภัณฑ์ การติดตั้ง การใช้งาน พารามิเตอร์ และการแก้ไขปัญหา