1. บทนำ
This manual provides essential information for the safe and efficient installation, operation, and maintenance of the Generic ZUKED 310 Series Variable Frequency Drive (VFD) Inverter. This VFD is designed to control the speed and torque of AC induction motors by varying the motor input frequency and voltage. Please read this manual thoroughly before installation and operation to ensure proper use and to prevent damage or injury.
2. ข้อมูลด้านความปลอดภัย
WARNING: Electrical shock hazard. Only qualified personnel should install, operate, and maintain this equipment.
- Always disconnect power before performing any wiring or maintenance. Wait at least 5 minutes after power-off for capacitors to discharge.
- ตรวจสอบให้แน่ใจว่าได้ต่อสายดินของ VFD และมอเตอร์อย่างถูกต้อง
- Do not touch internal components while power is applied or immediately after power-off.
- ควรปกป้อง VFD จากความชื้น ฝุ่นละออง ก๊าซกัดกร่อน และแสงแดดโดยตรง
- ตรวจสอบปริมาณอินพุตtage matches the VFD's specifications before connecting power.

รูปที่ 2.1: Front panel of the VFD, showing the display, control buttons, and a 'DANGER 5 min' warning indicating residual voltage หลังจากปิดเครื่อง
3. คุณสมบัติของผลิตภัณฑ์
The ZUKED 310 Series VFD Inverter offers robust performance and versatile control for various industrial applications. Key features include:
- ฉบับกว้างtagความเข้ากันได้: Supports 3-phase input/output for industrial motors, with models for 1-phase 220V input to 3-phase 220V output, and 3-phase 380V input to 3-phase 380V output.
- การควบคุมมอเตอร์ที่แม่นยำ: Advanced vector control technology ensures precise torque and speed regulation with a typical speed accuracy of ±0.5%.
- การออกแบบที่แข็งแกร่ง: Compact structure with an IP55-rated dust and water-resistant enclosure, suitable for harsh workshop conditions.
- Integrated Automation: Features an integrated PID controller, RS485 communication interface, and multiple I/O ports for seamless automation system integration.
- ประสิทธิภาพการใช้พลังงาน: An energy-saving mode automatically adjusts output to match load demands, potentially reducing power consumption by 30%-60%.
- ฟังก์ชันการป้องกัน: Includes comprehensive protection against overcurrent, overvoltage, overload, phase loss, and short circuits.
- ปริมาณการส่งออกtage ระเบียบข้อบังคับ: Built-in Automatic Voltage Regulation (AVR) function maintains stable output voltage.

รูปที่ 3.1: เกินview of the ZUKED 310 Series VFD Inverter.

รูปที่ 3.2: VFD model indicating 380V/220V compatibility and 11KW power rating.

รูปที่ 3.3: VFD model indicating 220V/380V compatibility and various power ratings from 0.75KW to 5.5KW.
4. ข้อมูลจำเพาะ
| ข้อมูลจำเพาะ | ค่า |
|---|---|
| หมายเลขรุ่น | JBAQJAEEA-ZUKED-11KW-3PH380V-3PH380V |
| อินพุต Voltagอี (1 เฟส) | ไฟฟ้ากระแสสลับ 220 โวลต์ ±10% |
| ปริมาณการส่งออกtage (3-phase from 1-phase input) | ไฟฟ้ากระแสสลับ 0-240 โวลต์ |
| อินพุต Voltagอี (3 เฟส) | ไฟฟ้ากระแสสลับ 380 โวลต์ ±10% |
| ปริมาณการส่งออกtage (3-phase from 3-phase input) | ไฟฟ้ากระแสสลับ 0-440 โวลต์ |
| ตัวเลือกกำลังขับ | 0.75KW, 1.5KW, 2.2KW, 4KW, 5.5KW, 7.5KW, 11KW |
| ความถี่เอาต์พุต | 0-320เฮิรตซ์ |
| วิธีการควบคุม | การควบคุม V/F, การควบคุมเวกเตอร์ |
| คุณสมบัติการป้องกัน | กระแสเกิน, ปริมาตรเกินtage, Overload, Phase Loss, Short Circuit |
| ฟังก์ชั่นพิเศษ | Simple PLC, Built-in PID, AVR Function |
| ขนาดแพ็คเกจ | ขนาด 0.39 x 0.39 x 0.39 นิ้ว (โดยประมาณ) |
| น้ำหนักสินค้า | 3.53 ออนซ์ (โดยประมาณ) |
5. การติดตั้งและการเดินสายไฟ
5.1 ข้อกำหนดด้านสิ่งแวดล้อม
- อุณหภูมิ: 0°C ถึง 40°C (32°F ถึง 104°F)
- ความชื้น: ความชื้นสัมพัทธ์น้อยกว่า 90% ไม่มีการควบแน่น
- ที่ตั้ง: Avoid direct sunlight, corrosive gases, flammable materials, and excessive dust. Ensure adequate ventilation.
5.2 การเชื่อมต่อสายไฟ
Proper wiring is crucial for safe and reliable operation. Refer to the wiring diagrams below for correct connections.

รูปที่ 5.1: Single-phase and Three-phase wiring diagrams for the VFD.
5.2.1 Power Input (R, S, T / L1, L2)
- Single-Phase 220V Input: Connect the live wire to L1 and the neutral wire to L2.
- Three-Phase 380V Input: Connect the three phase wires to R, S, and T terminals.
- Always ensure a fuse is installed on the input line for protection.
5.2.2 Motor Output (U, V, W)
Connect the three motor phase wires to the U, V, and W terminals of the VFD. Ensure correct phase sequence for desired motor rotation. If the motor rotates in the wrong direction, swap any two of the U, V, W connections.
5.2.3 Braking Resistance (P+, PB)
If dynamic braking is required, connect an external braking resistor between the P+ and PB terminals. Refer to the VFD specifications for appropriate braking resistor values.
5.2.4 Grounding (PE)
Connect the PE (Protective Earth) terminal to a reliable ground point. Proper grounding is essential for safety and to minimize electromagnetic interference.
5.2.5 ขั้วต่อควบคุม
The VFD features various control terminals for external control signals, including digital inputs (DI), analog inputs (AI), analog outputs (AO), and communication ports (RS485). Refer to the detailed diagram for specific terminal functions.

รูปที่ 5.2: รายละเอียด view of the VFD's control and power terminals.

รูปที่ 5.3: ด้านข้าง view of the VFD, showing model details and ventilation.
6. การตั้งค่าและการกำหนดค่า
The VFD's control panel allows for parameter setting and monitoring. The display shows operational status and parameter values, while buttons like PRG, M-FUN, SHIFT, RUN, STOP/REST, UP, DOWN, and ENTER are used for navigation and input.
6.1 Basic Parameter Settings
Upon initial power-up, it is essential to configure basic motor parameters and operating modes. Common parameters include:
- กำลังมอเตอร์: Set according to your motor's nameplate.
- มอเตอร์จัดอันดับVoltage: Set according to your motor's nameplate.
- มอเตอร์จัดอันดับปัจจุบัน: Set according to your motor's nameplate.
- ความถี่เอาต์พุตสูงสุด: Typically 50Hz or 60Hz, but can be set up to 320Hz.
- Acceleration/Deceleration Time: Adjust these parameters to control how quickly the motor speeds up or slows down.
- โหมดการควบคุม: Select between V/F control (Volts per Hertz) or Vector control based on application requirements. Vector control offers better performance for demanding applications.
Refer to the detailed parameter list in the full product manual (if available) for advanced settings, including PID control, simple PLC functions, and communication settings.
7. การดำเนินการ
Once the VFD is correctly installed and configured, operation is straightforward.
7.1 การสตาร์ทเครื่องยนต์
กดปุ่ม วิ่ง button on the control panel or activate the corresponding external run command (if configured). The motor will accelerate to the set frequency according to the acceleration time parameter.
7.2 การหยุดมอเตอร์
กดปุ่ม หยุดพัก/พัก button on the control panel or activate the corresponding external stop command. The motor will decelerate to a stop according to the deceleration time parameter.
7.3 Adjusting Frequency/Speed
ใช้ ▲ (ขึ้น) และ ▼ (Down) arrow buttons on the control panel to adjust the output frequency, thereby changing the motor speed. The display will show the current output frequency or motor speed.

รูปที่ 7.1: Examples of industrial applications suitable for the VFD.
8. การบำรุงรักษา
การบำรุงรักษาอย่างสม่ำเสมอจะช่วยให้ VFD ของคุณมีอายุการใช้งานยาวนานและทำงานได้อย่างน่าเชื่อถือ
- การทำความสะอาด: Periodically clean the VFD's exterior and cooling fins to prevent dust accumulation, which can hinder heat dissipation. Use a soft, dry cloth. Do not use liquid cleaners.
- การตรวจสอบ: Regularly inspect wiring connections for tightness and signs of corrosion or damage. Check for any unusual noises or odors during operation.
- การตรวจสอบสิ่งแวดล้อม: ตรวจสอบให้แน่ใจว่าสภาพแวดล้อมการทำงานยังคงอยู่ในขีดจำกัดอุณหภูมิและความชื้นที่กำหนด
- เช็คพัดลม: Verify that the cooling fan (if present) is operating correctly and not obstructed.
WARNING: Always disconnect power and wait for the discharge period before performing any maintenance or inspection.
9 การแก้ไขปัญหา
ส่วนนี้ให้คำแนะนำสำหรับปัญหาทั่วไป สำหรับปัญหาที่ซับซ้อน โปรดติดต่อฝ่ายสนับสนุนด้านเทคนิค
| อาการ/รหัสข้อผิดพลาด | สาเหตุที่เป็นไปได้ | สารละลาย |
|---|---|---|
| มอเตอร์ไม่ทำงาน | No power, incorrect wiring, stop command active, parameter error. | Check power supply, verify wiring, ensure run command is active, check motor parameters. |
| ความผิดพลาดของกระแสไฟเกิน | Motor overload, short circuit in motor/cables, acceleration time too short. | Reduce load, check motor and cables, increase acceleration time, verify motor parameters. |
| โอเวอร์โวลtagความผิดพลาด | Deceleration time too short, input voltage too high, regenerative load. | Increase deceleration time, check input voltage, consider adding a braking resistor. |
| อันเดอร์โวลtagความผิดพลาด | ปริมาณอินพุตtage too low, power supply instability. | ตรวจสอบอินพุต voltage, ensure stable power supply. |
| โอเวอร์โหลดข้อบกพร่อง | Motor or VFD overloaded. | Reduce mechanical load, check motor parameters, ensure VFD is correctly sized for the motor. |
10. การรับประกันและการสนับสนุน
Specific warranty terms and conditions for the Generic ZUKED 310 Series VFD Inverter are not provided within the product details. Please refer to your purchase documentation or contact your vendor for warranty information and technical support.