DIGITEN DHC312

DIGITEN Humidity Controller DHC312 User Manual

Model: DHC312 | Brand: DIGITEN

1. บทนำ

This manual provides detailed instructions for the installation, operation, and maintenance of the DIGITEN DHC312 Humidity Controller. This pre-wired digital humidistat is designed to regulate and maintain desired humidity levels in various environments, offering both humidification and dehumidification capabilities. It also features a real-time temperature display for comprehensive environmental management.

DIGITEN DHC312 Humidity Controller with sensor and power cord

Image 1.1: The DIGITEN DHC312 Humidity Controller, showing the main unit, power outlet, power plug, and humidity sensor.

2. คุณสมบัติของผลิตภัณฑ์

  • High-Precision Swiss-Imported Humidity Sensor: Regulates humidity within 5% to 99% RH with an accuracy of ±3%RH.
  • การแสดงอุณหภูมิแบบเรียลไทม์: Monitors ambient temperature (Note: The device measures temperature but does not control it).
  • Convenient Plug & Play Operation: Non-programmable design for ease of use; no complex programming required.
  • Intelligent Dual-Stagอี การควบคุม: Seamlessly switches between humidification and dehumidification modes. Requires humidifiers with automatic restart functions.
  • การใช้งานที่หลากหลาย: Suitable for home brewing, reptile habitats, greenhouses, mushroom cultivation, grow tents, meat drying, and incubation.
  • ฟังก์ชั่นเพิ่มเติม: Supports switching between °C/°F, calibration, and compressor delay functions.
DIGITEN DHC312 Humidity Controller with features listed: Large Screen, Humidification and Dehumidification, Memory function, °C/°F Switchable, Plug and Play, Non Programmable

ภาพที่ 2.1: จบแล้วview of the DHC312 controller highlighting its key features such as large screen, dual-mode operation, and plug-and-play functionality.

Close-up of the Swiss high-precision Sensirion sensor component

ภาพที่ 2.2: รายละเอียด view of the high-precision Swiss-imported humidity sensor, emphasizing its compact design and internal components.

3. เนื้อหาบรรจุภัณฑ์

The DIGITEN DHC312 Humidity Controller package includes the following items:

  • 1 x DIGITEN DHC312 Humidity Controller Unit
  • 1 x คู่มือผู้ใช้
Contents of the DIGITEN DHC312 package including the controller, power outlet, sensor, and manual

Image 3.1: The complete package contents, showing the main controller unit, the dual-outlet power strip, the humidity sensor, and the instruction manual.

4. ข้อมูลจำเพาะ

ข้อมูลจำเพาะค่า
หมายเลขรุ่นดีเอชซี312
ช่วงการควบคุมความชื้นสัมพัทธ์ 5-99%
การแก้ปัญหาความชื้นความชื้นสัมพัทธ์ 0.1%
ความแม่นยำ±3%ความชื้นสัมพัทธ์
โหมดการควบคุมHumidify or Dehumidify
กำลังไฟเข้า100~240VAC, 50/60เฮิรตซ์
Relay Contact Capacity (Humidify)10A, 100~240VAC
Relay Contact Capacity (Dehumidify)10A, 100~240VAC
ความยาวสายเซ็นเซอร์2เมตร/6.56ฟุต
ความยาวของสายไฟอินพุต150ซม. / 4.92ฟุต
ความยาวสายไฟขาออก18ซม. / 0.59ฟุต
สีสีดำ
วัสดุพลาสติก
ประเภทจอภาพดิจิตอล
น้ำหนักสินค้า15.8 ออนซ์
ขนาดแพ็คเกจ7.8 x 3.5 x 3.5 นิ้ว
Diagram showing the dimensions and specifications of the DIGITEN DHC312 Humidity Controller

Image 4.1: Visual representation of the controller's dimensions and key technical specifications.

5. คำแนะนำในการตั้งค่า

The DIGITEN DHC312 is designed for plug-and-play convenience. Follow these steps for initial setup:

  1. การจัดวาง: Position the main controller unit in a stable location.
  2. การเชื่อมต่อเซนเซอร์: Ensure the humidity sensor is securely connected to the main controller unit. Place the sensor probe in the environment where humidity needs to be monitored and controlled. Avoid placing it near direct airflow or heat sources for accurate readings.
  3. การเชื่อมต่อไฟฟ้า: Plug the controller's power plug into a standard electrical outlet (100-240VAC).
  4. การเชื่อมต่ออุปกรณ์:
    • For humidification, plug your humidifier into the outlet labeled "HUMIDIFICATION" on the dual-stage power strip.
    • For dehumidification, plug your dehumidifier or exhaust fan into the outlet labeled "DEHUMIDIFICATION".

    สำคัญ: Ensure your humidifier has an automatic restart function for seamless operation with this controller.

DIGITEN DHC312 Dual-Relay humidity controller showing humidification and dehumidification outlets in a greenhouse setting

Image 5.1: The dual-relay power strip connected to the controller, illustrating the separate outlets for humidification and dehumidification appliances.

6. คู่มือการใช้งาน

The DHC312 features a clear digital display and intuitive buttons for easy operation.

6.1 แสดงผลเกินview

Close-up of the DIGITEN DHC312 display showing working mode, current temperature, current humidity, setting humidity, difference, and calibration indicators

ภาพที่ 6.1: รายละเอียด view of the controller's LCD screen, indicating various display elements such as current temperature, current humidity, and set humidity.

  • โหมดการทำงาน: Indicates whether the unit is in humidification or dehumidification mode.
  • อุณหภูมิปัจจุบัน: Displays the real-time ambient temperature.
  • ระดับความชื้นปัจจุบัน: Shows the real-time ambient humidity percentage.
  • Setting Humidity (SET): Displays the target humidity percentagคุณก็ได้ตั้งค่าไว้แล้ว
  • Difference (DIFF): Indicates the humidity differential setting.
  • Calibration (CA): Indicates if calibration is active.

6.2 การกำหนดระดับความชื้นเป้าหมาย

  1. กดปุ่ม Up () หรือ ลง () button to adjust the target humidity value (SET).
  2. After setting the desired value, wait approximately 5 seconds. The controller will automatically save the setting and return to the normal display mode.

6.3 Advanced Settings (Temperature Unit, Difference, Calibration)

  1. กดค้างไว้ ชุด button for 3 seconds until the °C or °F indicator flashes.
  2. While the indicator is flashing, short press the ชุด button to cycle through the advanced settings: Temperature Unit (°C/°F), Difference (DIFF), and Calibration (CA).
  3. ใช้ Up () หรือ ลง () buttons to adjust the value for the selected setting.
  4. กดค้างไว้ ชุด button for 3 seconds to save the changes and exit the advanced settings menu.
Diagram illustrating how to set the target humidity and access advanced settings on the DIGITEN DHC312

Image 6.2: Step-by-step guide on setting the target humidity and accessing advanced functions like °C/°F switching, difference, and calibration.

6.4 Humidification and Dehumidification Logic

The controller operates based on the set humidity value and the difference (DIFF) setting:

  • การเพิ่มความชื้น: The humidification outlet turns ON when the measured humidity is ≤ (Setting Value - DIFF). It turns OFF when the measured humidity is ≥ Setting Value.
  • การลดความชื้น: The dehumidification outlet turns ON when the measured humidity is ≥ (Setting Value + DIFF). It turns OFF when the measured humidity is ≤ Setting Value.
Visual representation of humidification and dehumidification modes in different environments

ภาพที่ 6.3: อดีตamples of the controller managing humidity in a greenhouse (humidification) and a poultry farm (dehumidification).

7. การสอบเทียบ

The DHC312 allows for humidity calibration to ensure accuracy. If you have a trusted reference hygrometer, you can adjust the controller's reading.

  1. Access the advanced settings menu by long pressing the ชุด กดปุ่มนี้เป็นเวลา 3 วินาที
  2. กดสั้น ๆ ชุด button until 'CA' (Calibration) is displayed.
  3. ใช้ Up () หรือ ลง () buttons to adjust the calibration value. This value will offset the measured humidity.
  4. กดค้างไว้ ชุด เป็นเวลา 3 วินาทีเพื่อบันทึกและออก

8 การแก้ไขปัญหา

If you encounter issues with your DIGITEN DHC312, refer to the following common problems and solutions:

ปัญหาสาเหตุที่เป็นไปได้สารละลาย
จอแสดงผลคอนโทรลเลอร์ปิดอยู่ไม่มีแหล่งจ่ายไฟCheck if the power plug is securely inserted into a live outlet. Verify the outlet is functioning.
ค่าความชื้นที่วัดได้ไม่แม่นยำSensor dirty or improperly placed; calibration needed.Clean the sensor gently. Relocate the sensor away from direct airflow or heat. Perform a calibration as described in Section 7.
Humidifier/Dehumidifier not activating.Incorrect settings; appliance not working; appliance lacks auto-restart.Verify the target humidity and DIFF settings. Ensure the appliance is plugged into the correct outlet and is functional. Confirm your appliance has an auto-restart function.
การแสดงอุณหภูมิไม่ถูกต้องSensor issue or environmental factors.Ensure the sensor is not exposed to extreme temperatures or direct sunlight. The controller measures, but does not control, temperature.

9. การบำรุงรักษา

To ensure the longevity and accurate performance of your DIGITEN DHC312 Humidity Controller, follow these maintenance guidelines:

  • การทำความสะอาด: Periodically wipe the main unit and display with a soft, dry cloth. Do not use abrasive cleaners or immerse the unit in water.
  • การดูแลเซ็นเซอร์: Keep the humidity sensor clean and free from dust, debris, or moisture buildup. Gently clean the sensor housing if necessary.
  • พื้นที่จัดเก็บ: If storing the controller for an extended period, disconnect it from power, clean it, and store it in a cool, dry place away from direct sunlight and extreme temperatures.
  • สภาพแวดล้อม : Avoid exposing the controller to corrosive gases, high humidity (beyond its operating range), or extreme temperatures, which can affect its performance and lifespan.

10. การรับประกันและการสนับสนุน

DIGITEN provides a one-year warranty for any quality problems encountered with this product. For technical support, warranty claims, or further assistance, please contact DIGITEN customer service through your purchase platform or the official DIGITEN webเว็บไซต์.

For more information about DIGITEN products, please visit the DIGITEN Store.

© 2025 DIGITEN สงวนลิขสิทธิ์ทุกประการ

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.