การแนะนำ
This manual provides instructions for the installation, operation, and maintenance of the Opengear CM8100 Console Server. The CM8100 series is designed to provide secure out-of-band management for network and server infrastructure, enabling remote access and control even during primary network outagใช่
Key features of the CM8100 Console Server include:
- 16, 32, or 48 port serial console server with Smart Out-of-Band™ capabilities.
- Support for Data Center and Enterprise Network automation with Python and Docker.
- Embedded physical security via TPM 2.0 module.
- Dual power supplies for redundancy and independent monitoring.
- Integrated environmental temperature monitoring.
การติดตั้งและการตั้งค่า
This section guides you through the physical installation and initial setup of your CM8100 Console Server.
การแกะกล่องอุปกรณ์
Carefully unpack all components from the box. Verify that all items listed in the "What's in the Box" section are present and undamaged.
ภาพ: ด้านหน้า view of the Opengear CM8100 Console Server, showing the red and black chassis, Opengear logo, model number, and dual power inlets on the right side.
การติดตั้งแร็ค
The CM8100 Console Server is designed for standard 19-inch rack installation.
- Attach the two rack ears to the sides of the console server using the provided M4 screws.
- Secure the console server into the rack using the four M5x15mm rack screws and M5mm caged nuts. Ensure the device is level and securely fastened.
การเชื่อมต่อไฟฟ้า
The CM8100 features dual power supplies for redundancy.
- Connect the two A/C power cables to the power inlets on the rear of the console server.
- Connect the other ends of the power cables to independent power sources for redundancy.
- Verify that the power indicator LEDs on the front panel illuminate, indicating successful power-up.
การเชื่อมต่อเครือข่าย
Connect the console server to your network for management access.
- Connect an Ethernet cable from your network switch to the primary network port on the console server.
- (Optional) Connect a second Ethernet cable to the secondary network port for network redundancy.
การเชื่อมต่อพอร์ตอนุกรม
Connect your managed devices (servers, network devices) to the serial ports on the CM8100.
- Identify the serial ports on the rear of the console server.
- Use appropriate serial cables (e.g., the provided CAT5 patch cable with DB9F-RJ45 rollover serial adapter) to connect your devices to the CM8100 serial ports.
- Note the port numbers for future configuration.
ภาพ: ด้านหลัง view of the Opengear CM8100 Console Server, displaying various network and serial console ports, along with dual power supply connections.
การดำเนินการ
This section covers basic operation and initial access to the CM8100 Console Server.
การเข้าถึงเบื้องต้น
Access the console server for initial configuration via a direct serial connection or network connection.
Serial Console Access
- Connect a computer to the console server's dedicated console port using a serial cable.
- ตั้งค่าโปรแกรมจำลองเทอร์มินัลของคุณ (เช่น PuTTY, Tera Term) ด้วยการตั้งค่าต่อไปนี้: อัตราการส่งข้อมูล 115200 บอด, 8 บิตข้อมูล, ไม่มีพาริตี, 1 บิตหยุด, ไม่มีการควบคุมการไหลของข้อมูล
- Power on the CM8100. The boot process will display on your terminal.
- Log in using the default credentials (refer to the Quick Start Guide for default username and password).
Network Access (Web อินเตอร์เฟซ)
Once the device has an IP address (either DHCP assigned or manually configured via serial console), you can access the web อินเทอร์เฟซ
- เปิด web browser and enter the IP address of the CM8100.
- เข้าสู่ระบบโดยใช้ข้อมูลประจำตัวของคุณ
- จาก web interface, you can configure serial ports, network settings, user accounts, and other system parameters.
การจัดการอุปกรณ์ที่เชื่อมต่อ
The CM8100 allows you to connect to the console of your attached devices.
- การเข้าถึงคอนโซลแบบอนุกรม: จาก web interface or command-line interface (CLI), select the desired serial port to establish a connection to the attached device.
- การจัดการนอกช่องทาง: Utilize the Smart OOB™ features to access and manage devices even when the primary network is down.
การซ่อมบำรุง
Regular maintenance ensures optimal performance and longevity of your CM8100 Console Server.
อัพเดตเฟิร์มแวร์
Periodically check the Opengear website for firmware updates. Keeping the firmware current provides new features, bug fixes, and security enhancements.
- Download the latest firmware image from the official Opengear support portal.
- Access the CM8100 web อินเทอร์เฟซ
- Navigate to the firmware update section (typically under System > Firmware).
- ทำตามคำแนะนำบนหน้าจอเพื่ออัปโหลดและติดตั้งเฟิร์มแวร์ใหม่ ห้ามปิดเครื่องระหว่างกระบวนการอัปเดต
การทำความสะอาด
Keep the console server clean to prevent dust buildup, which can affect cooling.
- ใช้ผ้าแห้งนุ่มเช็ดบริเวณภายนอกของอุปกรณ์
- ตรวจสอบให้แน่ใจว่าช่องระบายอากาศไม่มีสิ่งกีดขวาง
- ห้ามใช้น้ำยาทำความสะอาดโดยตรงกับอุปกรณ์
การพิจารณาด้านสิ่งแวดล้อม
Ensure the operating environment meets the recommended conditions.
- Maintain proper airflow around the device.
- Keep the device within specified temperature and humidity ranges.
การแก้ไขปัญหา
This section provides solutions to common issues you might encounter with the CM8100 Console Server.
ไม่มีไฟฟ้า
- อาการ: Power indicator LEDs are off, device does not respond.
- สารละลาย: Verify that both A/C power cables are securely connected to the device and to active power outlets. Check power sources and circuit breakers.
ไม่สามารถเข้าถึง Web อินเทอร์เฟซ
- อาการ: Web browser cannot connect to the CM8100 IP address.
- สารละลาย:
- Verify the console server has power and is running.
- Confirm the network cable is properly connected to an active network port.
- Check the IP address configuration of the CM8100 (via serial console if necessary).
- Ensure your computer is on the same network or has a route to the CM8100's IP address.
- ปิดใช้งานไฟร์วอลล์ใดๆ บนคอมพิวเตอร์ของคุณชั่วคราว เพื่อป้องกันการรบกวน
No Serial Console Connection to Managed Device
- อาการ: Unable to establish a serial connection to a device connected to the CM8100.
- สารละลาย:
- Verify the serial cable connection between the CM8100 port and the managed device.
- Ensure the correct serial cable type (e.g., rollover, straight-through) is used for the specific device.
- Check the serial port configuration on the CM8100 (baud rate, data bits, parity, stop bits, flow control) matches the settings of the managed device.
- Confirm the managed device is powered on and functioning correctly.
ข้อมูลจำเพาะ
| คุณสมบัติ | รายละเอียด |
|---|---|
| ยี่ห้อ | โอเพ่นเกียร์ |
| ชุด | CM8100 Console Server |
| หมายเลขรุ่น | CM8116 |
| น้ำหนักสินค้า | 8.63 ปอนด์ |
| ขนาดสินค้า (กxยxส) | 19.5 x 16.5 x 3.5 นิ้ว |
| ผู้ผลิต | โอเพ่นเกียร์ |
| มีจำหน่ายครั้งแรก | 16 กุมภาพันธ์ 2023 |
มีอะไรอยู่ในกล่อง
The following items are included with your Opengear CM8100 Console Server:
- CM8100 Console Server
- ชุดติดตั้งแร็ค
- 2 x Rack Ears with Six M4 Screws
- 4 x M5mm Caged Nuts
- 4 x M5x15mm Rack Screws
- 1 x CAT5 Patch Cable 6'
- 1 x DB9F-RJ45 Rollover Serial Adapter
- 2 x A/C Power Cables
- คู่มือเริ่มต้นอย่างรวดเร็ว
- Lighthouse Insert