Walfront STVP-936

Walfront STVP-936 3-Phase Voltage คู่มือผู้ใช้ตัวป้องกัน

Model: STVP-936 (50A)

1. บทนำ

The Walfront STVP-936 series automatic reset over-voltage, ต่ำกว่า voltage, and multi-function protector is a sophisticated monitoring and auxiliary device designed for three-phase four-wire power systems and electrical equipment. This device provides comprehensive protection by instantly cutting off the power supply to prevent damage to electrical equipment when conditions such as overvoltage, อันเดอร์โวลtage, or overcurrent occur. Once the line voltage returns to normal, the protector automatically restores the power supply.

This protector integrates multiple functions including over-voltage, ต่ำกว่า voltage, over-current, three-phase current (voltage) unbalance, phase sequence (phase dislocation), and phase-break detection. It also features fault inquiry, voltmeter and ammeter functions, and the ability to restore factory settings. The clear LCD screen provides easy access to all functions and settings.

2. ข้อมูลด้านความปลอดภัย

คำเตือน: Installation and maintenance should only be performed by qualified electricians in accordance with local electrical codes and regulations. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • Ensure power is disconnected before installation or any maintenance.
  • Verify correct wiring connections for three-phase four-wire systems.
  • ห้ามใช้งานอุปกรณ์หากพบว่าได้รับความเสียหาย
  • ควรเก็บอุปกรณ์ให้ห่างจากความชื้นและอุณหภูมิที่สูงหรือต่ำเกินไป
  • The device is designed for indoor use within specified environmental conditions.

3. สินค้าหมดview

Walfront STVP-936 3-Phase Voltage Protector front view

รูปที่ 3.1 : ด้านหน้า view of the Walfront STVP-936 Voltage Protector, showing the LCD display and control buttons.

The STVP-936 is a compact device designed for DIN rail mounting. It features an LCD display for real-time voltage and current readings, as well as for navigating settings. Control buttons allow for adjustment of protection parameters.

คุณสมบัติหลัก:

  • Automatic reset function after fault clearance.
  • Integrated protection against over-voltage, ต่ำกว่า voltage, กระแสเกิน
  • Three-phase current (voltage) unbalance protection.
  • Phase sequence (phase dislocation) and phase-break protection.
  • Fault inquiry function.
  • Built-in voltmeter and ammeter.
  • Factory settings restoration option.
  • Clear LCD display for easy monitoring and configuration.

4. ข้อมูลจำเพาะ

Walfront STVP-936 Voltage Protector dimensions

Figure 4.1: Dimensions of the Walfront STVP-936 Voltagอี ผู้พิทักษ์

พารามิเตอร์ค่า
ประเภทสินค้าปรับระดับเสียงได้tagอี ผู้พิทักษ์
วัสดุพลาสติก
แบบอย่างSTVP-936
จัดอันดับVoltage (Three-Phase Four-Wire)230V/400VAC 50/60Hz
คะแนนปัจจุบันปรับได้ 1-50A (ค่าเริ่มต้น 50A)
โอเวอร์โวลtage Value Range221V-300V-OFF (default 280V)
โอเวอร์โวลtage Recovery Value Range220V- (default 250V)
โอเวอร์โวลtagเวลาดำเนินการ0.1 - 10 seconds (default 0.2 seconds)
อันเดอร์โวลtage Value Range219V-150V-OFF (default 160V)
อันเดอร์โวลtage Recovery Value Range220V-151V (default 180V)
อันเดอร์โวลtagเวลาดำเนินการ0.1 - 10 seconds (default 0.2 seconds)
Overcurrent Action Time1 - 512 seconds (default 5 seconds)
ปริมาตรสามเฟสtage Unbalance Value Range5%-90%-OFF (default 25%)
เฟส Voltage Unbalance Action Time0.1 - 10 seconds (default 2.0 seconds)
Power-On Delay Time2 - 255 seconds (default 2 seconds)
เวลาหน่วงในการกู้คืนความล้มเหลว2 - 512 seconds (default 60 seconds)
การใช้พลังงาน≤ 3VA
โหมดการแสดงผลจอแอลซีดี
Electrical Isolation Strength>2000VAC, pulse 2.5KV 1.2/50μS
อุณหภูมิสภาพแวดล้อมการทำงาน-20℃ ~ 50℃
ความชื้นของสภาพแวดล้อมการทำงาน<85%
Working Environment Altitudeไม่เกิน 2000 เมตร
ขนาดโดยประมาณ (ยาว x กว้าง x สูง)70 x 95 x 65 มม. (2.8 x 3.7 x 2.6 นิ้ว)
น้ำหนักสินค้า13.5 ออนซ์

5. การตั้งค่าและการติดตั้ง

The Walfront STVP-936 is designed for DIN rail mounting within an electrical enclosure. Ensure the enclosure provides adequate ventilation and protection from environmental factors.

Walfront STVP-936 showing IN and OUT terminals

รูปที่ 5.1 : ด้านหน้า view showing the 'IN' (input) and 'OUT' (output) terminals for wiring.

คำแนะนำในการเดินสายไฟ:

  1. การตัดการเชื่อมต่อไฟฟ้า: Before beginning any wiring, ensure that the main power supply to the circuit is completely disconnected and locked out to prevent accidental re-energization.
  2. การติดตั้ง: Mount the STVP-936 onto a standard DIN rail securely.
  3. Input Wiring (IN terminals):
    • Connect the incoming three-phase power lines (L1, L2, L3) and the Neutral line (N) to the corresponding 'IN' terminals at the top of the device.
    • ตรวจสอบให้แน่ใจว่าการเชื่อมต่อทั้งหมดแน่นหนาและปลอดภัย เพื่อป้องกันการหลวมของหน้าสัมผัสและความร้อนสูงเกินไป
  4. Output Wiring (OUT terminals):
    • Connect the protected load's three-phase power lines (L1, L2, L3) and the Neutral line (N) to the corresponding 'OUT' terminals at the bottom of the device.
    • Verify that the load's current requirements do not exceed the device's maximum current rating (50A for this model).
  5. การต่อลงดิน: Ensure proper grounding of the electrical system as per local codes.
  6. การตรวจสอบ: Double-check all wiring connections for correctness and tightness before restoring power.
Walfront STVP-936 top-down view ของเทอร์มินัล

รูปที่ 5.2: จากบนลงล่าง view illustrating the terminal block layout for wiring connections.

6. คู่มือการใช้งาน

After successful installation and power-up, the device's LCD will display real-time voltage and current readings. The device is pre-configured with default settings, but these can be adjusted to suit specific application requirements.

Walfront STVP-936 LCD display and control buttons

Figure 6.1: Close-up of the LCD display and control buttons (SET, Up, Down).

จอแสดงผลและการควบคุม:

  • จอแสดงผล LCD: แสดงปริมาณแบบเรียลไทม์tage (V), current (A), and various protection parameters during configuration.
  • ปุ่ม ตลท.: Used to enter the setting mode and confirm parameter changes.
  • ปุ่มขึ้น/ลง: Used to navigate through settings and adjust parameter values.

การปรับพารามิเตอร์:

  1. กดปุ่มค้างไว้ ชุด button for a few seconds to enter the parameter setting mode.
  2. ใช้ Up และ ลง buttons to scroll through the different adjustable parameters (e.g., Overvoltage Value, Undervoltage Value, Overcurrent Action Time, etc.).
  3. When the desired parameter is displayed, press the ชุด button briefly to select it for adjustment.
  4. ใช้ Up และ ลง buttons to change the value of the selected parameter.
  5. กดปุ่ม ชุด button again to confirm the new value and move to the next parameter, or to exit the setting mode if no further changes are needed.
  6. If no buttons are pressed for a certain period, the device may automatically exit the setting mode and save changes.

Refer to the Specifications section (Section 4) for the default values and adjustable ranges of each parameter.

Fault Inquiry and Reset:

  • The device automatically detects faults and disconnects power. The LCD will typically display the type of fault.
  • After a fault condition clears and the recovery delay time (default 60 seconds) has passed, the device will automatically reset and restore power.
  • To inquire about past faults, consult the device's specific menu options using the SET and Up/Down buttons.
  • To restore factory settings, there is usually a specific sequence or menu option. Refer to the on-screen prompts or a more detailed manufacturer's guide if available.

7. การบำรุงรักษา

The Walfront STVP-936 Voltage Protector is designed for minimal maintenance. However, regular checks can ensure optimal performance and longevity.

  • การตรวจสอบภาพ: ตรวจสอบอุปกรณ์เป็นระยะเพื่อดูว่ามีร่องรอยความเสียหายทางกายภาพ การเปลี่ยนสี หรือการเชื่อมต่อหลวมหรือไม่
  • การทำความสะอาด: Keep the device clean and free from dust. Use a dry, soft cloth for cleaning. Do not use liquid cleaners or solvents.
  • การตรวจสอบการเชื่อมต่อ: Ensure all wiring connections remain tight and secure. Loose connections can lead to overheating and device malfunction.
  • สภาพแวดล้อม : ตรวจสอบว่าสภาพแวดล้อมการทำงานยังคงอยู่ภายในช่วงอุณหภูมิและความชื้นที่กำหนด
  • การทดสอบการทำงาน: If possible and safe to do so, periodically test the protection functions by simulating a fault condition (e.g., temporarily reducing voltage if a test setup is available) to ensure the device responds correctly. This should only be done by qualified personnel.

อย่าพยายามเปิดหรือซ่อมแซมอุปกรณ์ด้วยตนเอง แนะนำให้ส่งช่างผู้ชำนาญเข้ารับบริการทั้งหมด

8 การแก้ไขปัญหา

This section provides guidance for common issues. For problems not listed here, contact technical support.

ปัญหาสาเหตุที่เป็นไปได้สารละลาย
อุปกรณ์ไม่เปิดเครื่องไม่มีไฟเข้า; การเดินสายไฟไม่ถูกต้อง; ความผิดพลาดภายในCheck main power supply. Verify input wiring (L1, L2, L3, N). If power is present and wiring is correct, the device may be faulty.
อุปกรณ์ตัดการทำงานบ่อยครั้งเล่มที่tage fluctuations (over/under); overcurrent condition; phase unbalance; incorrect settings.Monitor line voltage and current. Check load for overcurrent. Verify protection parameter settings (overvoltage, อันเดอร์โวลtage, overcurrent, unbalance thresholds). Adjust settings if necessary, ensuring they are appropriate for your system.
Device does not reset after fault clears.Fault condition still present; recovery delay time not elapsed; internal fault.Ensure the fault condition (e.g., overvoltage) has genuinely cleared. Wait for the configured failure recovery delay time to elapse. If the issue persists, power cycle the device (if safe) or contact support.
LCD display is blank or erratic.No power; display fault; internal malfunction.Check power supply. If power is present, try power cycling the device. If the problem persists, the device may require servicing.
ไม่สามารถปรับการตั้งค่าได้Incorrect button sequence; device locked.Ensure you are pressing and holding the SET button correctly to enter setting mode. Follow the operating instructions precisely.

9. การรับประกันและการสนับสนุน

Specific warranty information for the Walfront STVP-936 Voltage Protector is not provided in this manual. Please refer to the product packaging, your purchase documentation, or contact your retailer or Walfront customer service for details regarding warranty coverage and terms.

For technical support, troubleshooting assistance beyond this manual, or inquiries about replacement parts, please contact Walfront customer support through their official webเว็บไซต์หรือข้อมูลการติดต่อที่ให้มาพร้อมกับการซื้อของคุณ

© 2024 Walfront. All rights reserved. Information subject to change without notice.

Ask a question about this manual