DANOPLUS KIB-006

DANOPLUS K Type Thermometer Data Logger

Model: KIB-006 - Instruction Manual

1. บทนำ

The DANOPLUS KIB-006 is a 4-channel K-type thermocouple thermometer data logger designed for precise temperature measurement and recording. This device allows for simultaneous monitoring of up to four temperature points, storing data directly onto an SD card for easy retrieval and analysis without requiring specialized software. It features a large LCD with backlight for clear readings, programmable high/low limit alarms, and various measurement functions suitable for a wide range of industrial, laboratory, and environmental applications.

DANOPLUS KIB-006 4-channel K-type thermometer data logger with four yellow thermocouple probes connected, displaying temperature readings on its screen.

Image: The DANOPLUS KIB-006 thermometer with four K-type thermocouple probes connected, showing its digital display and an 8GB SD card.

2. เนื้อหาบรรจุภัณฑ์

กรุณาตรวจสอบเนื้อหาในแพ็คเกจเมื่อได้รับเพื่อให้แน่ใจว่าสินค้าทั้งหมดอยู่ในที่เดิมและไม่ได้รับความเสียหาย:

  • 1 x DANOPLUS KIB-006 4-Channel K-Type Thermometer SD Logger
  • 2 x K-Type Thermocouple Probes
  • 1 x 8GB SD Card
  • แบตเตอรี่ AA 4 ก้อน
  • 1 x English Operation Manual (this document)
  • Standard Factory Packaging
Contents of the DANOPLUS KIB-006 package, including the thermometer, two K-type thermocouples, an 8GB SD card, and batteries.

Image: The DANOPLUS KIB-006 thermometer, two K-type thermocouples, an 8GB SD card, and batteries, representing the included items.

3. คุณสมบัติหลัก

  • 4-Channel Measurement: Simultaneously displays temperature readings from up to four K-type thermocouple probes.
  • SD Card Data Logging: Records unlimited temperature data directly to an included 8GB SD card in TXT format, eliminating the need for software.
  • Programmable High/Low Limit Alarm: Features an audible buzzer and LED indicator that activate when temperature thresholds are exceeded.
  • ช่วงการวัดกว้าง: Capable of measuring temperatures from -200 to 1370°C (-328 to 2498°F) for the main unit.
  • Large LCD with Backlight: Provides clear temperature readings and operational status, with an adjustable backlight for low-light conditions.
  • MAX/MIN/HOLD Function: ช่วยให้ผู้ใช้งานสามารถ view maximum, minimum, and hold current measured values on the screen.
  • หน่วยที่สามารถสลับได้: สามารถสลับระหว่างองศาเซลเซียส (°C) และองศาฟาเรนไฮต์ (°F) ได้อย่างง่ายดาย
  • Differential Temperature (T1-T2): Calculates and displays the temperature difference between two selected channels.
  • ปิดเครื่องอัตโนมัติ: ช่วยประหยัดแบตเตอรี่โดยการปิดเครื่องอัตโนมัติหลังจากไม่มีการใช้งาน 20 นาที
Diagram showing the key features of the DANOPLUS KIB-006 thermometer, including 4 channels, SD card datalogger, wide measurement range, Hi/Low temperature alarm, switchable temperature unit, and data hold function.

Image: Visual representation of the thermometer's features, including its 4-channel capability, SD card data logging, wide measurement range, alarm, unit switching, and data hold.

4. คู่มือการติดตั้ง

4.1. การติดตั้งแบตเตอรี่

  1. ค้นหาฝาครอบช่องใส่แบตเตอรี่ที่ด้านหลังของอุปกรณ์
  2. เลื่อนฝาเปิดออก
  3. ใส่แบตเตอรี่ AA จำนวน 4 ก้อน โดยให้แน่ใจว่าขั้วถูกต้อง (+/-)
  4. ปิดฝาช่องใส่แบตเตอรี่ให้แน่น

4.2. การใส่การ์ด SD

  1. หาช่องเสียบการ์ด SD ที่ด้านข้างของอุปกรณ์
  2. Gently insert the provided 8GB SD card into the slot until it clicks into place. Ensure the card is oriented correctly.
  3. To remove, press the SD card inward until it springs out.
ภาพระยะใกล้ view of the DANOPLUS KIB-006 showing the SD card slot and how to insert an SD card.

Image: Demonstrates the insertion of an SD card into the data logger for data storage.

4.3. การเชื่อมต่อเทอร์โมคัปเปิล

  1. Identify the four K-type thermocouple input ports on the top of the device, labeled CH1, CH2, CH3, and CH4.
  2. Connect the K-type thermocouple probes to the desired channels. Ensure the positive (+) and negative (-) terminals of the probe match the corresponding markings on the device's input ports.
  3. Gently push the probe connectors firmly into the ports until they are secure.
ภาพระยะใกล้ view of the DANOPLUS KIB-006's four K-type thermocouple input ports, showing a yellow probe being inserted into one of the channels.

Image: Illustrates the connection of a K-type thermocouple probe into one of the four input channels on the device.

5. การดำเนินการ

5.1. เปิด/ปิดเครื่อง

  • กดปุ่ม เปิด/ปิด ปุ่มเพื่อเปิดเครื่อง
  • ในการปิดเครื่องให้กดปุ่ม เปิด/ปิด กดปุ่มนี้ประมาณ 3 วินาที

5.2. การควบคุมแบ็คไลท์

  • กดปุ่ม เปิด/ปิด button briefly to toggle the LCD backlight on or off.

5.3. การวัดอุณหภูมิ

  • Once powered on and thermocouples are connected, the device will immediately begin displaying real-time temperature readings for each active channel.

5.4. MAX/MIN/HOLD Function

ฟังก์ชันนี้ช่วยให้คุณ view the maximum, minimum, and current held values during a measurement session.

  1. กดปุ่ม สูงสุด/ต่ำสุด/คงค่า button once to display the maximum (MAX) temperature recorded.
  2. กดปุ่ม สูงสุด/ต่ำสุด/คงค่า button again to display the minimum (MIN) temperature recorded.
  3. กดปุ่ม สูงสุด/ต่ำสุด/คงค่า button a third time to hold the current readings (HOLD).
  4. กดปุ่ม สูงสุด/ต่ำสุด/คงค่า button a fourth time to return to real-time measurement mode.
Video demonstrating the MAX/MIN/HOLD function of the DANOPLUS KIB-006 thermometer. It shows how to cycle through maximum, minimum, and hold values on the display.

Video: Demonstration of the MAX/MIN/HOLD function on the DANOPLUS KIB-006 thermometer.

5.5. การบันทึกข้อมูลลงในการ์ด SD

The device records temperature data to the SD card in a simple TXT file format, which can be opened with any text editor or spreadsheet software.

  • ในการเริ่มบันทึก ให้กด บันทึก button. The 'REC' indicator will appear on the screen.
  • หากต้องการหยุดบันทึก ให้กด บันทึก button again. The 'REC' indicator will disappear.
  • ของampling rate for data logging can be programmed (refer to advanced settings in the full manual for details).

5.6. Alarm Function (High/Low Limit)

The thermometer features programmable high and low temperature alarms.

  • When a measured temperature exceeds the set high limit or falls below the set low limit, the device will activate an audible buzzer and an LED indicator.
  • Refer to the full manual for instructions on how to set specific high and low alarm thresholds.
DANOPLUS KIB-006 thermometer displaying temperature readings with an alarm icon and sound waves indicating the beeper/LED alarm function.

Image: The thermometer indicating an active alarm with visual and auditory cues.

5.7. การสลับหน่วย (°C/°F)

  • กดปุ่ม ° C / ° F button (often combined with another function button, refer to button labels) to toggle between Celsius and Fahrenheit temperature units.

5.8. Differential Temperature (T1-T2)

  • กดปุ่ม ทีโอที-ทีวัน button to display the temperature difference between channel 1 and channel 2.

6. การสมัคร

The DANOPLUS KIB-006 is suitable for a variety of temperature monitoring tasks, including but not limited to:

  • ระบบ HVAC: Monitoring air conditioning and heating system performance.
  • กระบวนการอุตสาหกรรม: Temperature control in manufacturing, machinery, and equipment.
  • การใช้ในห้องปฏิบัติการ: Research, experiments, and quality control requiring precise temperature data.
  • บริการด้านอาหาร: Monitoring temperatures in ovens, refrigerators, and freezers.
  • พิพิธภัณฑ์สัตว์น้ำ: Maintaining stable water temperatures for aquatic life.
  • Refrigeration Equipment: Performance testing and maintenance of cooling units.
Grid of images showing various applications for the DANOPLUS KIB-006 thermometer, including HVAC, microwave oven, industrial settings, laboratory, aquarium, and refrigeration equipment.

ภาพ: อดีตamples of diverse environments where the thermometer can be effectively utilized.

7. ข้อมูลจำเพาะ

พารามิเตอร์ค่า
Thermometer Main Unit Temp. Range-200 ถึง 1370°C (-328 ถึง 2498°F)
ปณิธาน0.1 องศาเซลเซียส, 0.1 องศาฟาเรนไฮต์
Accuracy (under 18-28°C ambient temp.)±(0.3%rdg + 1 °C)
K Bead Type Thermocouple Temp. Range-50 ถึง 200°C (-58 ถึง 392°F)
SampลิงอัตราProgrammable from 1 second up
ขนาดจอ LCD (สxก)47 x 104 มม. (1.85 x 4.1 นิ้ว)
อุณหภูมิในการทำงาน0 ถึง 50°C
ปฏิบัติการ RH%ความชื้น <80%
อุณหภูมิในการจัดเก็บ-20 ถึง 50°C
ที่เก็บ RH%ความชื้น <90%
ขนาด (ยาว x กว้าง x สูง)152 x 100 x 39 มม.
น้ำหนัก300g (0.66 ปอนด์)
แหล่งจ่ายไฟ4 x AA Batteries (included) or 9V adaptor (not included)
เทคโนโลยีการเชื่อมต่อการ์ด SD
ประเภทจอภาพจอแอลซีดี
วัสดุภายนอกพลาสติก
หมายเลขรุ่นKIB-006
ยูพีซี619317589858
Image showing the DANOPLUS KIB-006 thermometer with callouts for its main unit measuring range, K type thermocouple range, big LCD display dimensions, and portable design weight and dimensions.

Image: Detailed specifications and physical dimensions of the thermometer.

8. การบำรุงรักษา

  • การทำความสะอาด: เช็ดอุปกรณ์ให้สะอาดด้วยผ้าแห้งเนื้อนุ่ม ห้ามใช้สารทำความสะอาดที่มีฤทธิ์กัดกร่อนหรือตัวทำละลาย
  • การเปลี่ยนแบตเตอรี่: Replace all 4 AA batteries when the low battery indicator appears on the display to ensure accurate readings and proper operation.
  • พื้นที่จัดเก็บ: เมื่อไม่ได้ใช้งานเป็นเวลานาน ควรถอดแบตเตอรี่ออกและเก็บอุปกรณ์ไว้ในที่แห้งและเย็น หลีกเลี่ยงแสงแดดโดยตรงและอุณหภูมิที่สูงหรือต่ำเกินไป
  • การดูแลรักษาเทอร์โมคัปเปิล: Handle thermocouple probes carefully. Avoid bending or kinking the wires excessively, as this can affect accuracy. Replace damaged probes.

9 การแก้ไขปัญหา

ปัญหาสาเหตุที่เป็นไปได้สารละลาย
อุปกรณ์ไม่เปิดเครื่องแบตเตอรี่หมดหรือติดตั้งไม่ถูกต้องตรวจสอบขั้วแบตเตอรี่; เปลี่ยนด้วยแบตเตอรี่ AA ใหม่
No temperature reading / "----" on displayThermocouple not connected or faultyEnsure thermocouple is securely connected to the correct channel. Test with another probe if available.
การอ่านที่ไม่ถูกต้องDamaged thermocouple; incorrect probe type; environmental interferenceInspect probes for damage. Ensure K-type probes are used. Avoid strong electromagnetic fields.
Data not saving to SD cardSD card full or faulty; card not inserted correctly; recording not initiatedCheck SD card capacity. Reinsert SD card. Ensure 'REC' indicator is active. Try a different SD card.
นาฬิกาปลุกไม่ทำงานAlarm limits not set; alarm function disabledVerify alarm settings and ensure they are enabled.

10. การรับประกันและการสนับสนุน

The DANOPLUS KIB-006 comes with a standard manufacturer's warranty. For specific warranty details, please refer to the documentation included with your purchase or contact DANOPLUS customer support.

For technical assistance, troubleshooting beyond this manual, or to inquire about replacement parts, please contact your retailer or the manufacturer directly. Contact information can typically be found on the product packaging or the official DANOPLUS webเว็บไซต์.