FBT V350-4T0015

SIMPHOENIX V350 Series VFD Instruction Manual

Model: V350-4T0015

1. บทนำ

This manual provides essential information for the safe and efficient installation, operation, and maintenance of the SIMPHOENIX V350 series closed-loop vector inverter, model V350-4T0015. This Variable Frequency Drive (VFD) is designed for precise motor control in various industrial applications, including machine tools, textile machinery, road construction machinery, cable machinery, and petrochemical processing. Please read this manual thoroughly before using the product.

SIMPHOENIX V350 Series VFD

Figure 1: SIMPHOENIX V350 Series VFD unit.

2. คำแนะนำด้านความปลอดภัย

Observe all safety precautions to prevent personal injury or equipment damage. Improper installation or operation can lead to severe consequences.

  • อันตรายจากไฟฟ้า: Ensure power is disconnected before installation, wiring, or maintenance. Only qualified personnel should perform electrical work.
  • การต่อลงดิน: Always connect the VFD to a proper ground.
  • การคายประจุของตัวเก็บประจุ: Wait at least 10 minutes after power-off for internal capacitors to discharge before touching terminals. Verify voltage ด้วยมัลติมิเตอร์
  • สิ่งแวดล้อม: Install the VFD in a clean, dry, well-ventilated area, free from corrosive gases, dust, and direct sunlight.
  • ความเข้ากันได้ของมอเตอร์: Ensure the motor's voltage and current ratings are compatible with the VFD.
  • หยุดฉุกเฉิน: Implement an external emergency stop circuit independent of the VFD control.

3. สินค้าหมดview

3.1 คุณสมบัติหลัก

  • High Torque Performance: Achieves up to 200% start torque at zero speed in closed-loop vector mode and 180% in open-loop vector mode.
  • อินเทอร์เฟซผู้ใช้: Standard 5-digit two-line LED panel display; LCD keypad optional.
  • การตรวจสอบตามเวลาจริง: Vivid display for monitoring power, running time, input/output current, voltage, and failure records.
  • High Frequency Operation: Supports running modes up to 1000Hz.
  • Parameter Simplification: Built-in system and application macros simplify parameter settings.
  • Flexible Speed Control: Programmable 16-stage speed running, with adjustable running time, acceleration, deceleration, and direction for each stage.
  • อินพุต/เอาต์พุตเสมือน: Software virtual I/O function for flexible configuration, reducing external interference and simplifying wiring.
  • ฟังก์ชันการป้องกัน: Abundant warning and protection features for safe operation.

3.2 ส่วนประกอบ

The V350 series VFD typically consists of:

  • แผงควบคุม: For parameter setting and status display.
  • ขั้วไฟฟ้า: For connecting input power and motor.
  • ขั้วควบคุม: For external control signals (e.g., start/stop, speed reference, fault output).
  • Heat Sink and Fan: เพื่อระบายความร้อนให้กับชิ้นส่วนภายใน

4. การตั้งค่าและการติดตั้ง

4.1 การติดตั้ง

Mount the VFD vertically on a non-flammable surface, ensuring adequate clearance for ventilation. Avoid mounting in direct sunlight or near heat sources. Maintain specified clearances above, below, and to the sides of the unit for proper airflow.

4.2 การเดินสายไฟ

All wiring must comply with local and national electrical codes. Use appropriate wire gauges and ensure all connections are secure.

  1. กำลังไฟเข้า (R, S, T): Connect the 380V AC power supply to the R, S, T terminals. Ensure correct phase sequence.
  2. กำลังไฟฟ้าขาออกของมอเตอร์ (U, V, W): Connect the motor to the U, V, W terminals. Do not connect power factor correction capacitors or surge suppressors between the VFD and the motor.
  3. การต่อสายดิน (PE): Connect the PE terminal to a reliable earth ground.
  4. ขั้วควบคุม: Wire control signals (e.g., start/stop, analog speed reference, digital inputs) according to your application requirements and the VFD's terminal diagram. Refer to the detailed wiring diagram in the full product manual for specific terminal assignments.

4.3 การเพิ่มพลังเริ่มต้น

Before applying power, double-check all wiring connections. Power on the VFD and observe the display. If any fault codes appear, refer to the troubleshooting section.

5. คู่มือการใช้งาน

5.1 การทำงานของแผงควบคุม

The VFD features a 5-digit two-line LED display and a keypad for parameter setting and monitoring. Common buttons include:

  • วิ่ง/หยุด: Starts and stops the motor.
  • PROG/ข้อมูล: Enters/exits parameter setting mode and confirms data.
  • ลูกศรขึ้น/ลง: Navigates through parameters and adjusts values.
  • กะ: Moves cursor during parameter editing.

5.2 Basic Parameter Settings

Key parameters to configure for initial operation include:

  • มอเตอร์จัดอันดับความถี่: Set to the motor's nominal frequency (e.g., 50Hz or 60Hz).
  • มอเตอร์จัดอันดับVoltage: Set to the motor's nominal voltagอี (เช่น 380V)
  • มอเตอร์จัดอันดับปัจจุบัน: Set to the motor's nominal current.
  • เวลาเร่งความเร็ว: Time taken for the motor to accelerate from 0Hz to maximum frequency.
  • เวลาลดความเร็ว: Time taken for the motor to decelerate from maximum frequency to 0Hz.
  • โหมดการควบคุม: Select between open-loop vector, closed-loop vector, or V/F control based on application requirements.

Refer to the detailed parameter list in the comprehensive manual for advanced settings and specific parameter codes.

6. การบำรุงรักษา

การบำรุงรักษาอย่างสม่ำเสมอจะช่วยให้ VFD ทำงานได้อย่างมีประสิทธิภาพสูงสุดและยืดอายุการใช้งาน

  • การทำความสะอาด: ควรทำความสะอาดภายนอกและช่องระบายอากาศของ VFD เป็นระยะ เพื่อป้องกันฝุ่นละอองสะสม ใช้ผ้าแห้งนุ่มๆ เช็ดทำความสะอาด ห้ามใช้น้ำยาทำความสะอาดชนิดเหลว
  • การตรวจสอบ: ตรวจสอบการเชื่อมต่อสายไฟอย่างสม่ำเสมอ เพื่อดูว่าแน่นหนาดีหรือไม่ และมีร่องรอยการสึกหรอหรือความเสียหายหรือไม่ ตรวจสอบดูว่ามีเสียงหรือกลิ่นผิดปกติเกิดขึ้นระหว่างการใช้งานหรือไม่
  • การระบายอากาศ : Ensure cooling fans are operating correctly and that airflow around the unit is unobstructed. Replace fans if they become noisy or stop working.
  • การตรวจสอบตัวเก็บประจุ: For long-term reliability, electrolytic capacitors may require inspection or replacement after several years of operation. This should be performed by qualified service personnel.

7 การแก้ไขปัญหา

This section provides solutions for common issues. For persistent or complex problems, contact technical support.

Fault Code/Symptomสาเหตุที่เป็นไปได้สารละลาย
OV (Overvoltage)ปริมาณอินพุตtage too high, regenerative braking.ตรวจสอบอินพุต voltage. Increase deceleration time. Install braking resistor if necessary.
OC (Overcurrent)Motor overload, short circuit, rapid acceleration/deceleration.Check motor load. Inspect motor and wiring. Increase acceleration/deceleration time.
OL (โอเวอร์โหลด)Motor or VFD overload.Reduce motor load. Check motor current settings. Ensure proper ventilation.
UV (Undervoltage)ปริมาณอินพุตtagอีต่ำเกินไปตรวจสอบแรงดันไฟฟ้าขาเข้าtage.
Err (External Fault)External fault input activated.Check external control circuit and devices connected to fault input terminals.

8. ข้อมูลจำเพาะ

Technical specifications for the SIMPHOENIX V350-4T0015 VFD:

พารามิเตอร์ค่า
ยี่ห้อFBT (SIMPHOENIX)
แบบอย่างV350-4T0015
อินพุต Voltageกระแสสลับ 380 โวลต์
กำลังไฟที่กำหนด1.5 กิโลวัตต์
วิธีการควบคุมClosed-loop vector, Open-loop vector, V/F control
ช่วงความถี่เอาท์พุทสูงถึง 1000Hz
แสดง5-digit two-line LED panel
ผู้ผลิตเอฟบีที
ASINB08QVWYYLT
วันที่พร้อมใช้งานครั้งแรก17 ธันวาคม 2020

9. การรับประกันและการสนับสนุน

This product is covered by a standard manufacturer's warranty against defects in materials and workmanship. The specific duration and terms of the warranty may vary. Please retain your proof of purchase for warranty claims.

For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact your authorized dealer or the manufacturer's customer support. Provide your product model number (V350-4T0015) and serial number when seeking support.

© 2023 FBT. All rights reserved. Information in this manual is subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.