diymore LCR-TC1

Diymore LCR TC1 ESR Transistor Tester Multifunction Tester User Manual

Brand: diymore | Model: LCR-TC1

ข้อมูลด้านความปลอดภัยที่สำคัญ

คำเตือน: The built-in Li-ion battery must not be immersed in water or placed near a heat source. For your personal safety, always observe the specifications and precautions for Li-ion batteries.

คำเตือน: Always discharge capacitors before connecting them to the tester! The tester can be damaged if capacitors are not discharged. It is not recommended to use the tester to measure batteries with voltage above 4.5V, as this may damage the tester.

Warning image showing a tester and a warning sign

Image: Important safety warnings regarding battery and capacitor handling.

สินค้าเกินview

The Diymore LCR TC1 is a versatile multifunction tester designed for identifying and measuring various electronic components. It features a clear TFT graphic display for easy reading of measurement results.

Diymore LCR TC1 Multifunction Tester with its packaging and accessories

Image: The Diymore LCR TC1 tester, its retail box, a USB charging cable, and test clips.

คุณสมบัติหลัก:

  • Multifunction Testing: Capable of detecting NPN and PNP transistors, capacitors, resistors, diodes, triodes, N-channel and P-channel MOSFETs, JFET, IGBT, Triac, and battery voltage.
  • TFT Graphic Display (160x128): Provides clear, graphical display of measurement results. Supports both Chinese and English languages.
  • ตัวถอดรหัสอินฟราเรด: Allows for decoding of infrared remote control signals, displaying the data code and infrared waveform.
  • ไฟ LED แสดงสถานะการชาร์จ: A red LED indicates charging status, turning green when fully charged.
  • การสอบเทียบอัตโนมัติ: Simplifies setup with an automatic calibration function.
Labeled diagram of the Diymore LCR TC1 tester showing its components

Image: A detailed diagram highlighting the 160x128 TFT display, IR receiver window, multifunction key, transistor test area, Zener diode test area, Micro USB charging interface, and charge indicator LED.

การตั้งค่า

การชาร์จครั้งแรก:

Before first use, ensure the device is fully charged. Connect the provided USB cable to the Micro USB charging interface on the tester and a suitable 4.5V power source. The charging indicator LED will glow red during charging and turn green once fully charged.

Note: Do not use a charging input voltage higher than 4.5V to prevent damage to the tester.

การจัดวางส่วนประกอบ:

The test socket is divided into a transistor test area and a Zener diode test area. Ensure components are placed in the correct area for accurate measurement.

Diagram showing component placement in the test socket

Image: A visual guide for correctly placing components into the test socket for measurement.

การสอบเทียบอัตโนมัติ:

To calibrate the tester, short-circuit the three test sockets. Briefly press the multifunction button. The tester will automatically calibrate. Follow any on-screen prompts during the calibration process; no further operations are required until prompted to disconnect the short circuit.

Image showing the tester during calibration with shorted pins

Image: The tester screen displaying the calibration process, with test pins shorted.

คำแนะนำการใช้งาน

Power On and Measurement:

When the tester is off, briefly press the multifunction button. The tester will power on and automatically begin a measurement cycle.

Tester screen showing a component test in progress

Image: The tester displaying the results of a component test, showing component type and pinout.

Automatic and Manual Shutdown:

  • ปิดเครื่องอัตโนมัติ: After a component test or infrared decoding is complete, the tester will automatically shut down after a set timeout period. The factory default timeout is 20 seconds. This timeout can be adjusted (10, 15, 20, 25 seconds) by shorting jumpers inside the device. This requires opening the casing and soldering, and static ESD protection is recommended.
  • การปิดระบบด้วยตนเอง: To force shutdown at any time, including during a measurement, long-press the multifunction button.

ขั้นตอนการทดสอบส่วนประกอบ:

With the tester off or after a completed test, insert the component's pins into the appropriate test area of the socket. Press the locking handle down. Briefly press the multifunction button. The tester will automatically measure the component and display the graphical results on the screen.

Tester screen showing capacitor ESR measurement

Image: The tester displaying the capacitance and Equivalent Series Resistance (ESR) of a capacitor.

Tester screen showing resistor value measurement

Image: The tester displaying the resistance value of a resistor.

Infrared (IR) Decoding:

After a component detection or at the main screen, point an infrared remote control towards the "IR" light window on the tester. Press a button on the remote control. If successful, the tester will decode the signal and display the data code and infrared waveform.

Tester screen showing infrared signal decoding

Image: The tester displaying decoded infrared data and waveform from a remote control.

การซ่อมบำรุง

To ensure the longevity and accurate performance of your Diymore LCR TC1 tester, follow these maintenance guidelines:

  • การทำความสะอาด: เช็ดอุปกรณ์ด้วยผ้านุ่มและแห้ง ห้ามใช้น้ำยาทำความสะอาดที่มีฤทธิ์กัดกร่อนหรือตัวทำละลาย
  • พื้นที่จัดเก็บ: เก็บเครื่องทดสอบไว้ในที่แห้งและเย็น หลีกเลี่ยงแสงแดดโดยตรงและอุณหภูมิที่สูงหรือต่ำเกินไป
  • การดูแลแบตเตอรี่ Avoid fully discharging the battery frequently. Recharge the device when the battery level is low. If storing for extended periods, charge the battery to approximately 50% every few months.
  • การคายประจุของตัวเก็บประจุ: Always ensure capacitors are fully discharged before connecting them to the tester to prevent damage to the device.

Troubleshooting (Frequently Asked Questions)

FAQ image with questions and answers about the tester

Image: A visual representation of common questions and answers regarding the tester's functionality.

  1. Can this transistor tester measure Darlington transistors?

    The output current of the tester is 6 mA, and the voltage is less than 5 V. High-power IGBTs, Thyristors, and Darlington transistors cannot be tested.

  2. Can this transistor tester measure hollow coils and power inductors?

    Hollow coils and power inductors cannot be measured directly. Please connect the corresponding color ring inductor for testing.

  3. Do I need to discharge the capacitor before measuring it?

    Yes, always discharge capacitors before connecting them to the tester. Failure to do so can damage the tester.

  4. How can I distinguish between the two measurement areas?

    Triodes, diodes, capacitors, etc., are measured in the "123" area; place them in positions "1" and "3". Zener diodes should be inserted into the "KAA" area for measurement.

  5. Why does the screen show a Zener diode when I measure resistance?

    Resistance cannot be measured in the "KAA" area. If you insert a component into the "KAA" area, it will be displayed as a Zener diode.

  6. Why is the resistance measurement inaccurate?

    If the measured resistance is less than 10 Ohms, this can cause inaccuracy in the reading.

ข้อมูลจำเพาะ

The following table details the technical specifications and measurement ranges for the Diymore LCR TC1 Multifunction Tester:

Table of main performance parameters for the tester

Image: A comprehensive table outlining component types, their measurable ranges, and parameter descriptions.

ข้อมูลจำเพาะค่า
ผู้ผลิตดิยมอร์
หมายเลขชิ้นส่วนD051055
น้ำหนักสินค้า120 กรัม
ขนาดแพ็คเกจ11.2 x 8.4 x 4.9 ซม.
แบตเตอรี่ต้องใช้แบตเตอรี่ลิเธียมโพลิเมอร์ 1 ก้อน (มีให้ในชุด)
หมายเลขรุ่นแอลซีอาร์-ทีซี1
สีแอลซีอาร์-ทีซี1
สไตล์ทันสมัย
วัสดุทีเอฟที
แหล่งพลังงานใช้พลังงานจากแบตเตอรี่
ความแม่นยำในการวัด0.1
ส่วนประกอบที่รวมอยู่Transistor-Tester
วันที่พร้อมใช้งานครั้งแรก20 พฤษภาคม 2020
Dimensions of the Diymore LCR TC1 tester

Image: The physical dimensions of the Diymore LCR TC1 tester, showing its length, width, and height.

การรับประกันและการสนับสนุน

ข้อมูลการรับประกัน:

Specific warranty details are typically provided at the point of purchase or within the product packaging. Please refer to your purchase receipt or the seller's terms and conditions for warranty coverage.

การสนับสนุนลูกค้า:

If you have any questions, encounter issues, or require assistance with your Diymore LCR TC1 tester, please feel free to contact the seller or Diymore customer support. Contact information can usually be found on the product packaging or the seller's page where the product was purchased.

© 2024 diymore สงวนลิขสิทธิ์ทุกประการ