HABOTEST HT106B

HABOTEST HT106B Socket Tester User Manual

รุ่น : HT106B

1. บทนำ

The HABOTEST HT106B Socket Tester is a compact and portable device designed for quick and accurate detection of socket wiring status. It features RCD (Residual Current Device) or GFCI (Ground Fault Circuit Interrupter) testing capabilities and voltage measurement with an LCD display. This manual provides essential information for safe and effective use of the device in various settings, including schools, laboratories, and factories.

HABOTEST HT106B Socket Tester alongside its user manual

Image 1: HABOTEST HT106B Socket Tester alongside its user manual.

2. คำแนะนำด้านความปลอดภัย

⚠คำเตือน:

  • Always read this instruction manual carefully before use and strictly observe all safety rules, cautions, and warnings.
  • To avoid possible electric shock or personal injury, always check the tester carefully for any damage before use. If any damage is found, discontinue use immediately and send it for repair.
  • Ensure the RCD test is performed only under correct wiring conditions.
  • When performing an RCD test, ensure all equipment on the power line is closed to prevent power failure or harm. Obtain permission if testing in public places.

3. การตั้งค่า

The HT106B Socket Tester is designed for immediate use. Simply plug the device into a standard three-hole power outlet to begin testing.

ด้านข้าง view of the HT106B Socket Tester plug

ภาพที่ 2: ด้านข้าง view of the HT106B Socket Tester, showing the plug pins.

4. คู่มือการใช้งาน

4.1. ฉบับtage ทดสอบ

Insert the tester into a standard three-hole power outlet. The socket voltage value will be displayed on the tester's LCD screen in Volts (V).

  • The test duration should not exceed 5 minutes.
  • Exercise caution to avoid touching the RCD button during voltage testing to prevent accidental tripping of the leakage protection switch.
ด้านหน้า view of HT106B Socket Tester showing LCD display with voltagอีอ่าน

ภาพที่ 3: ด้านหน้า view of the HT106B Socket Tester displaying a voltage reading on its LCD screen.

4.2. RCD (or GFCI) Test

Insert the tester into a correctly wired three-hole power socket. Press the RCD/GFCI test button for less than 3 seconds. A properly functioning RCD/GFCI should trip (turn off the power) at this time. If the RCD/GFCI does not trip, it indicates a failure and requires professional electrician maintenance.

  • The test duration should not exceed 5 minutes.
  • RCD and GFCI functions cannot be used simultaneously.

4.3. Wiring Status Detection

The HT106B Socket Tester uses a series of indicator lights to quickly identify the wiring status of the socket. Refer to the functional control table and indicator results below to interpret the findings.

Partial manual page showing RCD test instructions and functional control table

Image 4: Excerpt from the manual detailing RCD test instructions and the functional control table.

Indicator corresponding test results chart for HT106B Socket Tester

Image 5: Chart illustrating the indicator light patterns and their corresponding wiring test results.

Functional Control Table & Indicator Results
รูปแบบตัวบ่งชี้สถานะการเดินสายไฟ
Two red lights (top row)ถูกต้อง: Lines are connected normally.
Red light in the middle (top row)เปิดภาคพื้นดิน: The ground line is missing.
Red light on the left (top row)เปิดเป็นกลาง: The neutral wire is missing.
No red light (top row)เปิดสด: Lack of "fire line" (live wire).
Two red lights on the right (top row)สด/GRD ย้อนกลับ: Live and ground wires are misconnected.
Red lights on the left and right (top row)สด/ใหม่ย้อนกลับ: Wrong connection of live and neutral wires.
All three red lights (top row)LIVE/GRD ย้อนกลับ, GRD หายไป: Faulty phase connection and missing ground.

Note: This tester cannot distinguish between neutral line and ground wire reverse.

5. การบำรุงรักษา

การทำความสะอาด

Clean the tester with a soft, damp cloth. Do not use abrasive cleaners or other chemicals, as they may damage the device. Ensure the tester is completely dry before its next use.

6 การแก้ไขปัญหา

  • RCD/GFCI does not trip during test: This indicates that the RCD/GFCI has failed. Immediately contact a professional electrician for inspection and repair.
  • Wiring fault detected (e.g., Open Ground, Live/GRD Reverse): If the tester indicates a wrong connection, consult a professional electrician to repair the wiring. Do not attempt to fix faulty wiring yourself unless you are qualified.

7. ข้อมูลจำเพาะ

ยี่ห้อฮาโบเทสต์
แบบอย่างHT106B
ปฏิบัติการฉบับที่tage48 - 250V / 45 - 65Hz
การวัดปริมาตรtage48 - 250V / 45 - 65Hz
ความแม่นยำ(2.0% + 2)
ระดับความสูง< 2000 เมตร
RCD Test Current30มิลลิแอมป์
RCD กำลังทำงานtage220V ± 20V
GFCI Test Current> 5mA
GFCI ฉบับที่ทำงานtage110V ± 20V
อุณหภูมิในการทำงาน0°C - 40°C
ความชื้นในการทำงานความชื้นสัมพัทธ์ 20% - 75%
อุณหภูมิในการจัดเก็บ-10°C - 50°C
ความชื้นในการเก็บรักษาความชื้นสัมพัทธ์ 20% - 80%
น้ำหนักสินค้า59กรัม
ขนาดสินค้า58 x 64 x 60มม.
แหล่งพลังงานสายไฟ