1. บทนำ
The Walfront G3/8 Pressure Sensor is a high-precision device designed for accurate pressure measurement in various industrial and commercial applications. Featuring a robust stainless steel casing, advanced ceramic core, and customized processing chip, this sensor offers stable performance, high accuracy, and a long service life. It is equipped with IP65 protection and provides an analog signal output, making it suitable for integration into diverse monitoring systems.
This manual provides essential information for the proper installation, operation, and maintenance of your Walfront pressure sensor. Please read it thoroughly before use to ensure optimal performance and safety.
2. คุณสมบัติ
- ความแม่นยำสูง: Designed for precise pressure measurement.
- โครงสร้างทนทาน: สแตนเลสซีasing with an advanced ceramic core.
- ขนาดกะทัดรัดและน้ำหนักเบา: Small size and light weight for easy installation.
- ประสิทธิภาพที่มั่นคง: Ensures long-term low drift and extended operational life.
- การป้องกัน EMC: Enhanced stability and reliability.
- การป้องกัน IP65: Provides resistance against dust and water ingress.
- Analog Signal Output: Compatible with standard control systems.
- G3/8 Screw Connection: Standardized connection for easy integration.
3. ข้อมูลจำเพาะ
| พารามิเตอร์ | ค่า |
|---|---|
| ระดับการป้องกัน | IP65 |
| อินพุต Voltage | 5 ± 0.25 VDC / 5~32 VDC |
| เทคโนโลยี | Piezoresistance |
| การเชื่อมต่อสกรู | จี3/8 |
| สัญญาณเอาท์พุต | สัญญาณอนาล็อก |
| ช่วงการวัด | 0-5 BAR (Current Model) |
| แรงดันเกินพิกัด | 2 times full pressure |
| Blast Pressure | 3 times full pressure range |
| Accuracy (Non-linearity + Repeatability + Hysteresis) | ± 1% FS (0 ~ 80 °C) ± 1.5% FS (-20 ~ 100 °C) ± 3% FS (-40 ~ 125 °C) |
| การเชื่อมต่อไฟฟ้า | Packard connector (three-core) |
| วัสดุ | สแตนเลส |
| สี | เงิน |
| ยูพีซี | 765613925002 |
4. การตั้งค่า
4.1 การติดตั้งทางกายภาพ
- การตระเตรียม: Ensure the system where the sensor will be installed is depressurized and free of contaminants.
- ตำแหน่งการติดตั้ง: Select a mounting point that is representative of the pressure to be measured and easily accessible for maintenance. Avoid locations with excessive vibration or extreme temperatures beyond the sensor's operating range.
- การเชื่อมต่อ: Carefully screw the G3/8 threaded end of the sensor into the corresponding port. Use appropriate sealing tape or compound if necessary to ensure a leak-free connection. Do not overtighten, as this can damage the sensor or the port.
- ปฐมนิเทศ: The sensor can generally be installed in any orientation, but ensure the cable is not strained or exposed to sharp edges.

รูปที่ 1: ระยะใกล้ view of the G3/8 screw terminal for physical connection.

รูปที่ 2: ทั่วไป view of the Walfront pressure sensor.
4.2 การเชื่อมต่อไฟฟ้า
The sensor uses a three-wire electrical connection, typically compatible with Packard connectors. Refer to the wiring diagram below for correct connections.
- แหล่งจ่ายไฟ: Connect the positive power supply (5 ± 0.25 VDC or 5~32 VDC) to the designated positive terminal (Pin 1, typically Red wire).
- Common/Ground: Connect the common end (Pin 3, typically Black wire) to the system ground.
- สัญญาณเอาท์พุท: Connect the analog signal output (Pin 2, typically Blue/Green wire) to your measurement or control equipment. The output signal range is typically 0.5V to 4.5V for the 0-5 BAR range.

Figure 3: Electrical wiring diagram for the pressure sensor.
สำคัญ: ตรวจสอบแหล่งจ่ายไฟ voltage is within the specified range to prevent damage to the sensor. Incorrect wiring can lead to malfunction or permanent damage.
5. คู่มือการใช้งาน
5.1 การเปิดเครื่อง
Once physically and electrically connected, apply power to the sensor. The sensor will immediately begin measuring pressure and outputting an analog signal.
5.2 Reading the Analog Signal
เซ็นเซอร์ให้ปริมาณอนาล็อกtage output that corresponds to the measured pressure. For the 0-5 BAR model, the typical output range is 0.5V to 4.5V. You will need a suitable analog-to-digital converter (ADC) or control system (e.g., PLC, microcontroller) to interpret this voltage into a pressure reading.
Example Conversion (for 0-5 BAR, 0.5V-4.5V output):
- 0.5V typically corresponds to 0 BAR.
- 4.5V typically corresponds to 5 BAR.
The pressure (P) can be calculated from the measured voltage (V_out) using a linear interpolation formula:
P = ((V_out - V_min) / (V_max - V_min)) * (P_max - P_min) + P_min
ที่ไหน:
- V_out = Measured output voltage
- V_min = Minimum output voltagอี (เช่น 0.5V)
- V_max = Maximum output voltagอี (เช่น 4.5V)
- P_min = Minimum pressure (e.g., 0 BAR)
- P_max = Maximum pressure (e.g., 5 BAR)
5.3 ข้อพิจารณาด้านสิ่งแวดล้อม
Ensure the operating environment is within the sensor's specified temperature and humidity ranges. While the sensor has IP65 protection, avoid prolonged exposure to harsh chemicals or extreme physical impact.
6. การบำรุงรักษา
The Walfront pressure sensor is designed for low maintenance. However, periodic checks can help ensure its longevity and accuracy.
- การทำความสะอาด: If the sensor's exterior becomes dirty, wipe it with a soft, damp cloth. Do not use abrasive cleaners or solvents that could damage the stainless steel or sealing materials. Ensure the pressure port is clear of debris.
- ตรวจสอบการเชื่อมต่อ: Periodically inspect the physical and electrical connections for any signs of corrosion, loosening, or damage. Tighten connections as needed.
- ตรวจสอบการสอบเทียบ: For critical applications, periodically verify the sensor's readings against a known, calibrated pressure source. If significant drift is observed, consider recalibration or replacement.
- พื้นที่จัดเก็บ: If the sensor is to be stored for an extended period, ensure it is clean, dry, and protected from extreme temperatures and physical shock.
7 การแก้ไขปัญหา
7.1 No Output or Incorrect Readings
- ตรวจสอบแหล่งจ่ายไฟ: Verify that the sensor is receiving the correct input voltage (5 ± 0.25 VDC or 5~32 VDC) and that the polarity is correct.
- การเดินสายไฟ: Double-check all electrical connections against the wiring diagram (Figure 3). Ensure no wires are loose, shorted, or incorrectly connected.
- การประยุกต์ใช้แรงกด: Confirm that pressure is actually being applied to the sensor and that the pressure is within the 0-5 BAR measuring range.
- Measurement Equipment: Ensure your receiving equipment (ADC, PLC) is correctly configured to read the analog voltage signal (0.5V-4.5V) and that its input impedance is suitable.
- Physical Blockage: Inspect the pressure port for any blockages or debris that might prevent accurate pressure transmission.
7.2 Leaks at Connection Point
- ความแน่น: Ensure the G3/8 screw connection is adequately tightened.
- การปิดผนึก: Verify that appropriate sealing tape (e.g., PTFE tape) or thread sealant was used during installation and that it is applied correctly.
- ความเสียหาย: Inspect the threads on both the sensor and the mating port for any damage that could prevent a proper seal.
7.3 เซ็นเซอร์ไม่ตอบสนอง
- Environmental Extremes: Check if the sensor has been exposed to temperatures or pressures outside its specified operating limits, which could cause permanent damage.
- ความเสียหายทางกายภาพ: Inspect for any visible physical damage to the sensor casing or cable.
8. การรับประกันและการสนับสนุน
8.1 นโยบายการคืนสินค้า
This product is typically covered by a 30-day return policy for refunds or replacements, subject to the terms and conditions of your purchase. Please refer to your purchase documentation for specific details.
8.2 การสนับสนุนลูกค้า
For further assistance, technical inquiries, or support regarding your Walfront pressure sensor, please contact Walfront customer service through the retailer where the product was purchased. Walfront is committed to providing quality goods and services.