1. บทนำ
The AMTAST WA-60A Portable Water Activity Meter is designed for precise measurement of water activity (aw) in various substances, including food products like beef jerky, freeze-dried food, fruits, and vegetables. This device helps assess product preservation and stability by quantifying the free water content. Its portable design and integrated sensor make it a convenient tool for on-site analysis.
2. สินค้าหมดview

รูปที่ 2.1: The AMTAST WA-60A Water Activity Meter in use, displaying a water activity reading. This device measures free water activity to assess the preservation and stability of food, medicine, and other products.

รูปที่ 2.2: The AMTAST WA-60A Water Activity Meter with its sample plate. The kit typically includes the meter, sample plate, portable bag, and manual for accurate measurement of free water content.
คุณสมบัติหลัก:
- การออกแบบพกพา: Weighing approximately 100 grams, this meter is lightweight and suitable for on-the-go testing.
- การวัดที่แม่นยำ: Offers a measurement range of 0-1.0aw with a resolution of ±0.01aw and an accuracy of 0.02aw.
- เซนเซอร์แบบรวม: Features a non-conductive humidity sensor and integrated readings in a single unit, simplifying water activity analysis.
- การทดสอบอย่างรวดเร็ว: Provides rapid results, typically completing measurements within 5 minutes.
- จอแสดงผลที่ชัดเจน: Equipped with a 6-digit backlit LCD screen that simultaneously displays water activity (aw) and temperature.
- ฟังก์ชั่นที่เป็นมิตรต่อผู้ใช้: Includes automatic and manual shut-off options, along with a low battery indicator.

รูปที่ 2.3: รายละเอียด view of the meter's backlit LCD screen, showing both the water activity (aw) and temperature values for clear readings.

รูปที่ 2.4: Image showing the battery compartment for 2x1.5V AAA batteries and the non-conductive humidity sensor. The device also features automatic shutdown, manual shutdown, and alarm indication.
3. ข้อมูลจำเพาะ

รูปที่ 3.1: The AMTAST WA-60A Water Activity Meter shown alongside its key specifications.
| พารามิเตอร์ | ค่า |
|---|---|
| หมายเลขรุ่น | WA-60A |
| ช่วงการวัด | 0.00 ~ 1.00 aw |
| ปณิธาน | ±0.01 อ๊อฟ |
| ความแม่นยำ | ±0.02 อ๊อฟ |
| Temperature Operation Conditions | 0-50 องศาเซลเซียส |
| Humidity Operation Conditions | ความชื้นสัมพัทธ์ <95% |
| น้ำหนักสินค้า | 100 กรัม (3.53 ออนซ์) |
| แหล่งจ่ายไฟ | 2 x 1.5V AAA Size (UM-4) Battery (not included) |
| วัสดุ | เอบีเอส |
| ขนาด | Approximately 13.5 cm (5.3 inches) height, 7 cm (2.8 inches) width |
4. การตั้งค่า
Before first use, ensure the device is properly set up.
- การติดตั้งแบตเตอรี่: Open the battery compartment on the back of the meter. Insert two 1.5V AAA batteries, ensuring correct polarity. Close the compartment securely.
- Sampเลอผู้ถือ: The meter comes with a sample holder featuring a strong magnetic connection. Ensure the sample holder is clean and dry before use.
- Calibration (Highly Recommended): For accurate and reliable results, especially for food safety applications, it is highly recommended to calibrate the meter using certified water activity standards. This should be done in the range relevant to your testing.
4.1 วิดีโอ: This video demonstrates the setup and basic operation of the AMTAST WA-60A Water Activity Meter, including how to prepare samples for measurement.
5. การดำเนินการ
Follow these steps for accurate water activity measurement:
- เตรียมสampเลอ: วาง s . ของคุณample into a clean, dry sample cup. Ensure the sample fills the cup adequately without overflowing.
- สถานที่ampเลอ: วางตำแหน่ง sample cup onto the base of the meter. The magnetic sample holder will secure it in place.
- การปรับสมดุล: ขั้นตอนสำคัญ: After placing the sample and closing the meter, allow sufficient time for the sample to equilibrate with the sensor. This process can take several hours, or even overnight, depending on the sample type and environmental conditions. Do not turn on the meter immediately.
- เปิดเครื่อง: เมื่อ sample has equilibrated, turn on the meter while it is still closed on the sampเล.
- อ่านการวัด: The LCD screen will display the water activity (aw) and temperature. Allow the reading to stabilize before recording the final value.
- หมดแรง: The device features automatic and manual shut-off options. To manually turn off, press and hold the power button.
5.1 วิดีโอ: วิดีโอนี้ให้ข้อมูลทั่วไปเกี่ยวกับview of the AMTAST Smart Water Activity Meter, demonstrating its use in a laboratory setting.
5.2 วิดีโอ: This video demonstrates the process of using the Water Activity Meter for monitoring food water activity (AW).

รูปที่ 5.1: The meter is designed for quick and efficient testing, providing accurate readings for water activity measurements.

รูปที่ 5.2: The AMTAST WA-60A is widely used for testing water activity in various food products, including dried fruits, beef jerky, cookies, and sausages.
6. การบำรุงรักษา
- การทำความสะอาด: เก็บสไว้ample holder and sensor area clean and free from debris. Use a soft, dry cloth to wipe the device. Do not use abrasive cleaners or immerse the device in water.
- พื้นที่จัดเก็บ: Store the meter in its protective case in a cool, dry place when not in use. Remove batteries if storing for extended periods to prevent leakage.
- การสอบเทียบ: Regular calibration with known standards is essential to maintain accuracy. Refer to Section 4 for calibration recommendations.
7 การแก้ไขปัญหา
| ปัญหา | สาเหตุที่เป็นไปได้ | สารละลาย |
|---|---|---|
| Inaccurate or erratic readings | Insufficient equilibration time; lack of calibration; dirty sensor. | มั่นใจ sample equilibrates for several hours before measurement. Calibrate the device regularly with appropriate standards. Clean the sensor and sampผู้ถือเลอ |
| อุปกรณ์ไม่เปิดเครื่อง | แบตเตอรี่เสียหรือติดตั้งไม่ถูกต้อง | Check battery polarity. Replace batteries with fresh 1.5V AAA batteries. |
| จอภาพมืดหรืออ่านไม่ออก | แบตเตอรี่อ่อน | เปลี่ยนแบตเตอรี่ |
8. ข้อมูลด้านความปลอดภัย
- อย่าพยายามถอดประกอบหรือซ่อมแซมอุปกรณ์ด้วยตนเอง โปรดติดต่อช่างผู้ชำนาญการเพื่อขอรับบริการ
- เก็บอุปกรณ์ให้ห่างจากอุณหภูมิ ความชื้น และแสงแดดโดยตรง
- จัดการอุปกรณ์ด้วยความระมัดระวังเพื่อหลีกเลี่ยงความเสียหายทางกายภาพ
- ทิ้งแบตเตอรี่ตามระเบียบข้อบังคับในท้องถิ่น
9. การรับประกันและการสนับสนุน
For warranty information, technical support, or service inquiries, please contact AMTAST customer service. Refer to the product packaging or the official AMTAST webเว็บไซต์สำหรับรายละเอียดการติดต่อ
AMTAST Official Store: Visit the AMTAST Store on Amazon