การแนะนำ
This manual provides essential instructions for the safe and effective use of Rayovac Size 312 Hearing Aid Batteries. These zinc-air batteries are designed for advanced hearing aid devices, offering reliable power and a long shelf life. Please read this manual thoroughly before use.
ข้อมูลด้านความปลอดภัย
- เก็บให้พ้นมือเด็ก: Batteries can be swallowed. Ingesting batteries can cause serious injury or death. Seek immediate medical attention if a battery is swallowed.
- ใช้ครั้งเดียว: These are single-use batteries and are not rechargeable. Attempting to recharge them may lead to leakage or rupture.
- การกำจัด: ทิ้งแบตเตอรี่ที่ใช้แล้วตามระเบียบข้อบังคับของท้องถิ่น ห้ามทิ้งลงในกองไฟ
- พื้นที่จัดเก็บ: Store batteries in their original packaging in a cool, dry place away from direct sunlight and extreme temperatures.
- ปราศจากสารปรอท: Rayovac Size 312 batteries feature a mercury-free formula.
การติดตั้งและการตั้งค่า
Proper handling and installation ensure optimal performance and safety.
1. Opening the Battery Package
The Rayovac battery package is designed for ease of use and secure storage. It features a lock dial system on the back to prevent accidental spinning and a front-facing door for easy access to individual batteries.

Image: The front-facing door allows for easy removal of a single battery.
2. Removing a Battery
- Locate the front-facing door on the package.
- Open the door and carefully slide out one battery. The long, wide tabs on the battery are designed for easier handling.
- Close the door to keep the remaining batteries clean and secure.

Image: The long, wide tab on the battery facilitates easier handling.
3. Air Activation
Rayovac hearing aid batteries are zinc-air batteries, which means they are activated by air. Once you remove the protective tab, air enters the battery and activates it. For optimal performance, allow the battery to air activate for approximately 1 minute before inserting it into your hearing aid.
4. Inserting into Hearing Aid
- Open the battery compartment of your hearing aid.
- Insert the activated battery with the flat, positive (+) side facing up, or as indicated by your hearing aid manufacturer's instructions.
- Close the battery compartment securely. Your hearing aid should now power on.
Setup and Battery Change Demonstration Videos
Meet Our Easy to Use, Award-Winning Package
Video: This video demonstrates the features of the Rayovac battery packaging, including the lock dial system and front-facing door for easy battery access.
How to Change Your Hearing Aid Battery
Video: This video provides a step-by-step guide on how to replace a used hearing aid battery with a new Rayovac battery.
คำแนะนำการใช้งาน
Once installed, your Rayovac Size 312 batteries will power your hearing aid. These batteries are engineered for advanced hearing aid devices, supporting features such as audio streaming and phone calls.

Image: Rayovac batteries are designed for long-lasting performance.
Rayovac Size 312 batteries are designed to deliver consistent power throughout their lifespan. No other Size 312 hearing aid battery lasts longer on ANSI & IEC performance tests.

Image: These batteries boast a 4-year shelf life, ensuring readiness when needed.
การซ่อมบำรุง
Proper maintenance of your batteries and their storage can extend their effectiveness.
- การจัดเก็บข้อมูลที่ปลอดภัย: Always reclose the front-facing door of the battery package after removing a battery. This keeps the remaining batteries clean, secure, and protected from environmental factors.
- การจัดการ: The long, wide tabs on the batteries are designed to make handling easier, especially for individuals with dexterity challenges.
- หลีกเลี่ยงการปนเปื้อน: Do not touch the battery with dirty or greasy hands, as this can affect performance.
การแก้ไขปัญหา
If you experience issues with your Rayovac hearing aid batteries, consider the following common solutions:
- Hearing Aid Not Powering On:
- Ensure the protective tab has been completely removed from the battery.
- Verify the battery is inserted correctly into the hearing aid compartment, with the correct polarity.
- Allow 1 minute for air activation after removing the tab before insertion.
- อายุการใช้งานแบตเตอรี่สั้น:
- Ensure the battery tab was removed just prior to use, not significantly in advance.
- Check the expiration date on the battery package.
- Environmental factors like humidity and temperature can affect battery life.
- High-drain usage (e.g., continuous streaming) will naturally reduce battery life.
- Difficulty Removing Batteries from Package:
- Ensure the lock dial on the back of the package is disengaged to allow the batteries to rotate freely to the front-facing door.
- The package features a perforated rounded edge, allowing the dial to be completely removed for added convenience if preferred.
If problems persist, consult your hearing aid professional or contact Rayovac customer support.
ข้อมูลจำเพาะ
| คุณสมบัติ | รายละเอียด |
|---|---|
| หมายเลขรุ่น | บีดี15516 |
| ขนาดแบตเตอรี่ | 312 |
| ประเภทเซลล์แบตเตอรี่ | Zinc-Air |
| เล่มที่tage | 1.45 โวลต์ |
| การนำกลับมาใช้ซ้ำ | ใช้ครั้งเดียว |
| จำนวนหน่วย (ต่อแพ็ค) | 8 ชิ้น (แพ็คละ 7 ชิ้น) |
| อายุการเก็บรักษา | 4 ปี |
| ขนาดสินค้า | 0.31 x 0.31 x 0.14 นิ้ว |
| น้ำหนักสินค้า | 0.06 Pounds (per pack) |
| ผู้ผลิต | บริษัท สเปกตรัม แบรนด์ส อิงค์ |
การรับประกันและการสนับสนุน
Rayovac products are manufactured by Spectrum Brands Inc. For any questions regarding product performance, warranty claims, or technical support, please contact Spectrum Brands Inc. directly or refer to the contact information provided on the product packaging. Keep your purchase receipt for warranty purposes.