DIGITEN DHC-101

DIGITEN Digital Humidity Controller DHC-101 User Manual

รุ่น: DHC-101

1. บทนำ

The DIGITEN DHC-101 Digital Humidity Controller is a pre-wired, simple-stage electronic humidistat designed for precise humidity management. It is suitable for a wide range of applications including dehumidifiers, humidifiers, reptile enclosures, greenhouses, exhaust fans, and fermentation processes. Featuring a large, lighted LCD screen for easy readability and a user-friendly interface, this plug-and-play device ensures accurate and stable humidity control.

Applications of DIGITEN DHC-101 Humidity Controller

Image: The DIGITEN DHC-101 controller is versatile, suitable for applications such as homebrewing, seed germination, cheese making, and cigar storage, ensuring optimal humidity levels.

2. ข้อมูลด้านความปลอดภัย

  • Ensure the power supply matches the controller's specifications (100-240Vac).
  • Do not immerse the controller or sensor in water or expose to excessive moisture.
  • เก็บให้พ้นจากมือเด็ก
  • ห้ามถอดประกอบหรือดัดแปลงอุปกรณ์ แนะนำให้ช่างผู้ชำนาญเข้ารับบริการทั้งหมด
  • ถอดปลั๊กอุปกรณ์ทุกครั้งก่อนทำความสะอาดหรือบำรุงรักษา
  • The case is designed with fireproof ABS material, but avoid exposing it to open flames or extreme heat.

3. เนื้อหาบรรจุภัณฑ์

ตรวจสอบว่ามีรายการทั้งหมดอยู่ในแพ็คเกจ:

  • 1 x DHC-101 Humidity Controller
  • เซ็นเซอร์วัดความชื้น 1 ชิ้น
  • 1 x คู่มือผู้ใช้
DIGITEN DHC-101 Humidity Controller packaging

Image: The DIGITEN DHC-101 Humidity Controller is packaged securely in a brown and black box.

4. สินค้าหมดview

The DHC-101 controller features a main unit with an integrated display and control buttons, a high-accuracy humidity sensor, and a pre-wired power plug for easy installation.

DIGITEN DHC-101 Digital Humidity Controller with sensor and plug

Image: The DIGITEN DHC-101 Digital Humidity Controller, showing the main unit, connected humidity sensor, and power plug.

ด้านหน้า view of DIGITEN DHC-101 Humidity Controller

ภาพ: ด้านหน้าที่ใส view of the DIGITEN DHC-101 controller, highlighting its LCD display and control buttons.

DIGITEN DHC-101 Humidity Sensor

Image: The high-accuracy humidity sensor for the DHC-101 controller, featuring a 2-meter lead length.

DIGITEN DHC-101 Output Plug

Image: Detail of the pre-wired output plug, designed for connecting the controlled device to the DHC-101 controller.

5. ข้อมูลจำเพาะ

  • ช่วงการควบคุม: ความชื้นสัมพัทธ์ 5-99%
  • ความละเอียดความชื้น: ความชื้นสัมพัทธ์ 0.1%
  • ความแม่นยำ: ± 3% RH
  • โหมดการควบคุม: Humidify or Dehumidify
  • กำลังไฟฟ้าเข้า: 100-240Vac, 50/60Hz
  • Humidity Control Output: Max. 10A, 100-240VAC
  • Humidity Output Load: 1100W@110V, 2200W@220V
  • เสียงปลุก Buzzer: High and Low Humidity Alarm
  • รุ่นเซนเซอร์: MEAS HTG3500 series
  • Sensor Lead Length: 2เมตร (6ฟุต)
  • Relay Contact Capacity: Humidity (10A, 100-240VAC), Dehumidify (10A, 100-240VAC)
  • Input Power Cable Length: 150 ซม. (6 ฟุต)
  • Output Power Cable Length: 18ซม. (7นิ้ว)
  • วัสดุ: อะคริโลไนไตรล์ บิวทาไดอีน สไตรีน (ABS)

6. การตั้งค่า

ทำตามขั้นตอนเหล่านี้สำหรับการตั้งค่าเริ่มต้น:

  1. แกะ: Carefully remove the DHC-101 controller and its components from the packaging.
  2. เชื่อมต่อเซ็นเซอร์: Plug the humidity sensor into the designated port on the controller. Ensure a secure connection.
  3. เซ็นเซอร์ตำแหน่ง: Place the humidity sensor in the environment where humidity needs to be monitored and controlled. Ensure it is not directly exposed to water or extreme temperatures.
  4. เชื่อมต่ออุปกรณ์: Plug your humidifier or dehumidifier into the output socket of the DHC-101 controller.
  5. เปิดเครื่อง: Plug the DHC-101 controller's main power plug into a standard 100-240Vac electrical outlet. The LCD screen will illuminate.

7. คู่มือการใช้งาน

The DHC-101 operates in either Humidify or Dehumidify mode based on your set parameters.

การตั้งค่าพารามิเตอร์:

Use the 'SET' button to enter programming mode and the up/down arrows to adjust values. Press 'SET' again to confirm and move to the next parameter.

โหมดลดความชื้น:

To activate dehumidification, set the RUN humidity value to be สูงกว่า than the STOP humidity value. The LCD will display "MODE: DEHUMIDIFICATION".

  • When the measured humidity is higher than the set RUN humidity, the dehumidification equipment will start operating.
  • When the measured humidity reaches the set STOP humidity, the dehumidification equipment will stop operating.

โหมดเพิ่มความชื้น:

To activate humidification, set the RUN humidity value to be ต่ำกว่า than the STOP humidity value. The LCD will display "MODE: HUMIDIFICATION".

  • When the measured humidity is lower than the set RUN humidity, the humidification equipment will start operating.
  • When the measured humidity reaches the set STOP humidity, the humidification equipment will stop operating.

ฟังก์ชั่นปลุก:

The controller features a buzzer alarm for high and low humidity conditions. Refer to the detailed user manual included in the package for setting alarm thresholds.

8. การบำรุงรักษา

  • การทำความสะอาด: Wipe the controller and sensor with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • การดูแลเซ็นเซอร์: Keep the humidity sensor clean and free from dust or debris to ensure accurate readings. Avoid physical damage to the sensor.
  • พื้นที่จัดเก็บ: หากต้องเก็บรักษาอุปกรณ์เป็นเวลานาน ควรตัดการเชื่อมต่อจากแหล่งจ่ายไฟและเก็บไว้ในที่แห้งและเย็น

9 การแก้ไขปัญหา

Problem: Display is blank.
สารละลาย: Ensure the controller is properly plugged into a live power outlet. Check the power cable for any damage.
Problem: Appliance not turning on/off as expected.
สารละลาย: Verify that the RUN and STOP humidity settings are correctly configured for either humidification or dehumidification mode. Check if the appliance plugged into the controller is functioning correctly. Ensure the sensor is placed in an appropriate location and is not obstructed.
Problem: Humidity readings appear inaccurate.
สารละลาย: Clean the humidity sensor to remove any dust or debris. Ensure the sensor is not exposed to direct airflow, extreme temperatures, or moisture that could affect readings. If issues persist, the sensor may need replacement.
Problem: Buzzer alarm sounds frequently.
สารละลาย: Check the current humidity level against your set high and low alarm thresholds. Adjust the thresholds if necessary, or address the environmental conditions causing the humidity to exceed/fall below the set limits.

10. การรับประกันและการสนับสนุน

For warranty information and technical support, please refer to the contact details provided in the user manual included with your product or visit the official DIGITEN webไซต์นี้ โปรดเก็บใบเสร็จรับเงินที่ซื้อไว้เพื่อใช้เรียกร้องการรับประกัน

© 2024 DIGITEN สงวนลิขสิทธิ์ทุกประการ

Ask a question about this manual