1. บทนำ

The Atrix VACOHCS HEPA Certified Vacuum is designed for efficient and safe cleaning, particularly in environments requiring ultra-fine filtration. This manual provides essential information for the proper setup, operation, and maintenance of your vacuum to ensure optimal performance and user safety.

2. ข้อมูลด้านความปลอดภัย

Always read and understand all safety warnings and instructions before operating this appliance. Failure to follow these instructions may result in electric shock, fire, and/or serious injury.

  • Ensure the vacuum is unplugged before performing any maintenance or changing accessories.
  • Do not use the vacuum on wet surfaces or to pick up liquids. This vacuum is designed for dry hazardous material cleanup.
  • เก็บผม เสื้อผ้าที่หลวม นิ้ว และส่วนต่างๆ ของร่างกายให้ห่างจากช่องเปิดและชิ้นส่วนที่เคลื่อนไหว
  • ใช้เฉพาะตามที่อธิบายไว้ในคู่มือนี้เท่านั้น ใช้เฉพาะอุปกรณ์เสริมที่ผู้ผลิตแนะนำเท่านั้น
  • ควรระมัดระวังเป็นพิเศษเมื่อทำความสะอาดบนบันได
  • ห้ามหยิบจับสิ่งของที่กำลังเผาไหม้หรือมีควัน เช่น บุหรี่ ไม้ขีดไฟ หรือขี้เถ้าร้อน
  • The vacuum is equipped with a short electrical cord. Always use a suitable extension cord that is in good condition and rated for the vacuum's power requirements.

3. เนื้อหาบรรจุภัณฑ์

ตรวจสอบว่ารายการทั้งหมดที่ระบุไว้ด้านล่างนี้รวมอยู่ในแพ็คเกจของคุณ:

  • VACOHCS HEPA Vacuum Unit
  • OF612HE-IC HEPA CERTIFIED Filter Cartridge
  • สายไฟ 25 ฟุต
  • เครื่องมือซอกมุม
  • Crevice Tool Brush
  • Utility Nozzle and Brush
  • 19" Wand
  • สายยางใส
  • (2) Hose Plugs
  • สายสะพายไหล่ปรับได้
Atrix VACOHCS HEPA Certified Vacuum kit in red case

Figure 3.1: The Atrix VACOHCS HEPA Certified Vacuum kit, neatly organized within its durable red carrying case, showcasing the main unit, filter, and various accessories.

4. การตั้งค่า

Follow these steps for initial setup of your Atrix VACOHCS vacuum:

  1. ติดตั้งท่อ: Connect the clear hose to the vacuum's intake port. Ensure a secure fit to prevent loss of suction.
  2. ประกอบไม้กายสิทธิ์: Connect the 19" wand to the hose. Attach the desired cleaning tool (crevice tool, utility nozzle, etc.) to the end of the wand.
  3. เชื่อมต่อพลังงาน: Plug the vacuum's pigtail cord into a suitable 3-prong extension cord. Utilize the cord relief feature on the vacuum to alleviate pressure on the pigtail cord connection.
  4. Wear the Backpack: Adjust the shoulder straps and waist strap for a comfortable and secure fit. The ergonomic design allows for airflow between your back and the unit.

Video 4.1: This video demonstrates the assembly, ergonomic features, and practical use of the Atrix Ergo Pro Backpack Vacuum, including how to wear it comfortably and attach accessories.

Person wearing Atrix VACOHCS backpack vacuum while cleaning

Figure 4.2: A person wearing the Atrix VACOHCS backpack vacuum, demonstrating its ergonomic design and portability during a cleaning task.

5. คู่มือการใช้งาน

The Atrix VACOHCS is designed for versatile cleaning across various surfaces.

  1. เปิด/ปิดเครื่อง: Locate the power switch on the side of the vacuum unit. Flip the switch to the 'ON' position to start the vacuum.
  2. การทำความสะอาดพื้นผิว: Select the appropriate attachment for your cleaning task. Use the utility nozzle for general cleaning on hard floors, carpets, and upholstery. The crevice tool is ideal for tight spaces and edges.
  3. Adjusting the Wand: The 19" wand is extendable. Adjust its length to comfortably reach high or low areas without straining.
  4. ฟังก์ชั่นพัดลม: This vacuum can also function as a blower. Consult the full product manual for instructions on converting the unit to blower mode and using the specialized blower attachments.
Man using Atrix vacuum with long wand on a hard floor

Figure 5.1: A man efficiently cleaning a hard floor surface using the Atrix vacuum with its extended wand and floor tool, highlighting its versatility for different floor types.

6. การบำรุงรักษา

Regular maintenance ensures the longevity and efficiency of your Atrix VACOHCS vacuum, especially regarding its HEPA filtration system.

  1. การเปลี่ยนไส้กรอง: The VACOHCS uses an OF612HE-IC HEPA CERTIFIED Filter Cartridge. This is a sealed system designed for safe and simple replacement. When the filter is full, simply plug the intake and exhaust ports of the cartridge with the provided plugs, then pull the tabs to remove it. Dispose of the old filter according to local regulations for hazardous waste. Install a new filter cartridge by aligning it correctly and ensuring it clicks into place.
  2. No Secondary Filters: The sealed filter cartridge design eliminates the need for secondary or tertiary filters, reducing cross-contamination risks during changes.
  3. การทำความสะอาดทั่วไป: เช็ดด้านนอกของเครื่องดูดฝุ่นด้วยโฆษณาamp cloth as needed. Ensure all ports and connections are free of debris.

วิดีโอ 6.1: จบแล้วview of the ATRIX SafeGuard 360 filter system, detailing its components and the benefits of its sealed design for safe and simple filter changes.

Video 6.2: This video highlights the features and benefits of the ATRIX SafeGuard 360 HEPA H13 Certified Filter, emphasizing its individual testing and high efficiency for capturing fine particles.

7. ข้อมูลจำเพาะ

คุณสมบัติข้อมูลจำเพาะ
ยี่ห้อAtrix
ชื่อรุ่นVACOHCS
คุณสมบัติพิเศษแบบมีสาย
ประเภทตัวกรองCartridge (OF612HE-IC HEPA Certified)
ส่วนประกอบที่รวมอยู่HEPA Filter, 25 ft power cord, crevice tool, crevice tool brush, utility nozzle and brush, 19" wand, clear hose, (2) hose plugs, adjustable shoulder strap
ไร้สายมั้ย?เลขที่
การใช้งานที่แนะนำสำหรับผลิตภัณฑ์Carpet, Desk, Furniture, Hard Floor, Tile Floor, Hardwood, Rug, Garage, Bare Floor, Sofa
ฟอร์มแฟกเตอร์Handheld (with backpack harness)
สีสีขาว
ระดับเสียง73 เดซิเบล
Ampอีเรจ5.23 Amps
จำนวนรายการ1
ประเภทตัวควบคุมการควบคุมด้วยมือ
แรงม้ามอเตอร์0.84 แรงม้า
วิธีการควบคุมสัมผัส
สไตล์ขนาดกะทัดรัด
พกพาได้No (designed to be worn)
จำนวนระดับพลังงาน1
การใช้งานภายใน/ภายนอกอาคารในร่ม
แรงม้าสูงสุด0.84 แรงม้า
เทคโนโลยีการเก็บรวบรวมแบบสุญญากาศการดูด
ยูพีซี838067003296
ขนาดแพ็คเกจ20 x 9 x 6 นิ้ว
ASINB078Y7FTJM
คำแนะนำด้านพื้นผิวทุกชั้น
แหล่งพลังงานสายไฟ

8 การแก้ไขปัญหา

If you encounter issues with your Atrix VACOHCS vacuum, consider the following common troubleshooting steps:

  • ไม่มีไฟฟ้า: Check if the power cord is securely plugged into both the vacuum and a functioning electrical outlet. Ensure the extension cord is not damaged.
  • การสูญเสียแรงดูด: Inspect the hose and attachments for blockages. Verify that the filter cartridge is correctly installed and not completely full.
  • เสียงผิดปกติ: Turn off the vacuum immediately. Check for any foreign objects lodged in the hose, wand, or attachments. Ensure the filter is properly seated.
  • ความร้อนสูงเกินไป: If the vacuum shuts off unexpectedly, it may be due to overheating. Unplug the unit and allow it to cool down for at least 30 minutes. Check for blockages or a full filter that might be restricting airflow.

For persistent issues, please contact Atrix customer support.

9. การรับประกันและการสนับสนุน

For information regarding product warranty, returns, or technical support, please refer to the official Atrix webหรือติดต่อฝ่ายบริการลูกค้าโดยตรง โปรดเก็บใบเสร็จรับเงินไว้เป็นหลักฐานการซื้อสำหรับการเรียกร้องการรับประกันใดๆ

© 2026 Atrix สงวนลิขสิทธิ์ทุกประการ