1. บทนำ
This manual provides detailed instructions for the installation, operation, and maintenance of your Claber 90814 24V Solenoid Valve. This robust and reliable solenoid valve is designed for underground irrigation systems, ensuring efficient water management. It is engineered to operate effectively across a wide range of water pressures, from minimal to high, and is compatible with all Claber 24V programmers.

Image 1: Claber 90814 24V Solenoid Valve. This image shows the compact design of the valve, highlighting its inlet and outlet connections and the solenoid component.
2. ข้อมูลด้านความปลอดภัย
- Always disconnect power to the irrigation controller before installing or servicing the solenoid valve.
- Ensure all electrical connections are waterproof and comply with local electrical codes.
- Do not exceed the maximum operating pressure of 12 bar (174 psi).
- Install the valve in a location protected from freezing temperatures.
- Use appropriate tools for installation to avoid damaging the valve or piping.
3. เนื้อหาบรรจุภัณฑ์
ตรวจสอบว่าส่วนประกอบทั้งหมดมีอยู่ก่อนเริ่มการติดตั้ง:
- 1 x Claber 90814 24V Solenoid Valve
4. การตั้งค่าและการติดตั้ง
- เตรียมสถานที่: Choose a suitable location for the valve, typically within a valve box, ensuring it is accessible for maintenance and protected from direct sunlight or extreme weather.
- เชื่อมต่อท่อ: The valve features 1" female inlet and outlet threads. Apply PTFE tape or pipe sealant to the male threads of your irrigation pipes. Connect the inlet pipe to the side marked 'IN' or with an arrow indicating flow direction, and the outlet pipe to the other side. Hand-tighten, then use a wrench for a final quarter to half turn, avoiding over-tightening.
- การเชื่อมต่อไฟฟ้า: Connect the two wires from the solenoid to the corresponding 24V AC output terminals on your irrigation programmer. Ensure a secure, waterproof connection using appropriate connectors (e.g., waterproof wire nuts). This valve is compatible with any 24V AC multi-line programmer.
- การทดสอบการรั่วไหล: Before burying the valve, slowly turn on the main water supply and check for any leaks at the connections.
- การตรวจสอบการทำงานด้วยตนเอง: The valve is equipped with a manual open/close device. Turn the manual override lever or screw to the 'OPEN' position to allow water flow, then return it to 'CLOSE' to stop flow. This confirms the valve's mechanical function.
5. คู่มือการใช้งาน
The Claber 90814 solenoid valve operates automatically in conjunction with a 24V AC irrigation programmer.
- การทำงานอัตโนมัติ: Once connected to a compatible 24V AC programmer, the valve will open and close according to the schedule set on the programmer. When the programmer sends a 24V AC signal, the solenoid activates, opening the valve. When the signal is removed, the valve closes.
- การดำเนินการด้วยตนเอง: กรณีไฟดับtage or for testing purposes, you can manually open and close the valve using the integrated manual override mechanism. Locate the lever or screw on the solenoid and turn it to the 'OPEN' position for continuous water flow, or 'CLOSE' to stop the flow. Remember to return it to the 'AUTO' or 'CLOSED' position for automatic operation.
6. การบำรุงรักษา
- Solenoid Filter: The solenoid is equipped with an anti-sand filter. Periodically inspect and clean this filter to prevent blockages and ensure proper valve operation.
- ฤดูหนาว: In regions prone to freezing temperatures, it is crucial to drain the irrigation system, including the solenoid valve, to prevent damage from freezing water. Consult your irrigation system's winterization guide.
- การตรวจสอบทั่วไป: Annually inspect the valve for any signs of wear, leaks, or damage. Ensure electrical connections remain secure and waterproof.
7 การแก้ไขปัญหา
| ปัญหา | สาเหตุที่เป็นไปได้ | สารละลาย |
|---|---|---|
| วาล์วไม่เปิด | No power to solenoid; faulty wiring; clogged filter; low water pressure. | Check programmer schedule and power supply; inspect wiring connections; clean solenoid filter; verify water pressure. |
| วาล์วไม่ปิด | Debris in valve; faulty solenoid; manual override engaged. | Flush the system to clear debris; inspect/replace solenoid; ensure manual override is in 'CLOSED' or 'AUTO' position. |
| อัตราการไหลของน้ำต่ำ | Partially clogged filter; insufficient main water pressure. | Clean solenoid filter; check main water supply pressure. |
| Water leaks from valve | Loose connections; damaged O-rings/seals; cracked valve body. | Tighten connections; inspect and replace O-rings/seals; replace valve if body is cracked. |
8. ข้อมูลจำเพาะ
- หมายเลขรุ่น: 90814
- ยี่ห้อ: Claber
- ประเภทวาล์ว: โซลินอยด์วาล์ว
- ปฏิบัติการฉบับที่tage: กระแสสลับ 24 โวลต์
- เกลียวทางเข้า/ทางออก: 1" Female
- แรงดันการทำงาน: 0.5 12 ไปที่บาร์ (7.25 174 เพื่อปอนด์ต่อตารางนิ้ว)
- อัตราการไหล: 4.6 to 96 liters/minute
- อุณหภูมิในการทำงาน: +5 °C ถึง +70 °C (41 °F ถึง 158 °F)
- วัสดุ: Fiberglass-reinforced nylon body, Stainless steel metal components
- คุณสมบัติ: Anti-sand filter, Slow closing anti-water hammer device, Manual open/close control
- ข้อกำหนดที่สอดคล้อง: EN 1074-1, EN 1074-2, CE
- ขนาดแพ็คเกจ: 13.4 x 12.4 x 8.4 ซม.
- น้ำหนัก: 360 กรัม
9. การรับประกันและการสนับสนุน
Claber products are manufactured to high-quality standards. For information regarding warranty coverage, technical support, or spare parts, please refer to the official Claber webหรือติดต่อตัวแทนจำหน่ายที่ได้รับอนุญาตในพื้นที่ของคุณ เก็บใบเสร็จรับเงินไว้เป็นหลักฐานการซื้อ