This manual provides detailed instructions for the installation, operation, and maintenance of the DIGITEN G1 Water Flow Sensor, Model FL-808. This Hall effect flow sensor is designed for accurate measurement of liquid flow within a range of 1 to 60 liters per minute. Please read this manual thoroughly before use to ensure proper function and safety.

สินค้าเกินview

The DIGITEN G1 Water Flow Sensor (Model FL-808) is a robust and reliable device for measuring water flow. It features G1 (0.5 inch) threaded connections for easy integration into various systems. The sensor outputs a square wave pulse signal proportional to the flow rate, making it suitable for microcontrollers and other electronic systems.

คุณสมบัติหลัก:

  • โครงสร้างทนทาน: Waterproof, heat-resistant, pressure-resistant, and cold-resistant design.
  • ช่วงอัตราการไหลกว้าง: Measures flow from 1 to 60 Liters per minute.
  • ติดตั้งง่าย: Simple G1 (0.5 inch) threaded connections.
  • เอาท์พุตพัลส์: Generates a square wave pulse signal for flow rate calculation.
  • เป็นไปตามมาตรฐาน RoHS: เป็นไปตามมาตรฐานด้านสิ่งแวดล้อม

ข้อมูลด้านความปลอดภัย

  • ตรวจสอบให้แน่ใจว่าได้ถอดแหล่งจ่ายไฟออกก่อนการติดตั้งหรือการบำรุงรักษา
  • Do not exceed the maximum operating pressure of 1.75 MPa.
  • Verify correct wiring connections to prevent damage to the sensor or connected equipment.
  • Avoid installing the sensor in locations with extreme vibrations or corrosive environments.
  • This device is intended for water flow measurement. Do not use with other liquids without verifying compatibility.

เนื้อหาแพ็คเกจ

  • 1 x DIGITEN G1 Water Flow Sensor (Model FL-808)

ข้อมูลจำเพาะทางเทคนิค

แบบอย่างFL-808
วัสดุMetal (Internal components), Plastic (Housing)
ขนาดการเชื่อมต่อทางเข้า/ทางออกG1 (0.5 inch) Threaded
ช่วงอัตราการไหล1 - 60 ลิตร/นาที
แรงดันใช้งานสูงสุด1.75 MPa (17.5 บาร์)
ปฏิบัติการฉบับที่tagอี เรนจ์DC 5 - 24 V
กระแสไฟฟ้าที่ใช้งานCannot exceed 10 mA (at DC 5V)
สัญญาณเอาท์พุตSquare Wave Pulse
Frequency FormulaF = 4.8 * Q (L/min) ± 2%
Output Pulse per LiterApproximately 450 pulses/liter
อุณหภูมิในการทำงาน≤ 80 องศาเซลเซียส
ความชื้นในการทำงานความชื้นสัมพัทธ์ 35% - 90%
อุณหภูมิในการจัดเก็บ-25°C ถึง +80°C
ความชื้นในการเก็บรักษาความชื้นสัมพัทธ์ 25% - 95%
ความต้านทานฉนวน> 100 MΩ
ความยาวสายเคเบิล15 ซม.
น้ำหนักผลิตภัณฑ์80 กรัม

การติดตั้งและการตั้งค่า

1. การติดตั้งเครื่องกล

The flow sensor features G1 (0.5 inch) male threaded connections on both ends. Ensure the flow direction arrow on the sensor body aligns with the intended water flow in your system. Apply appropriate thread sealant (e.g., PTFE tape) to prevent leaks. Tighten connections securely but do not overtighten.

DIGITEN G1 Water Flow Sensor, front view

รูปที่ 1 : ด้านหน้า view of the DIGITEN G1 Water Flow Sensor, showing the G1 threaded connections and the product label.

Technical drawing of DIGITEN G1 Water Flow Sensor with dimensions

Figure 2: Technical drawing illustrating the dimensions and internal structure of the DIGITEN G1 Water Flow Sensor.

2. การเดินสายไฟฟ้า

The sensor has a 3-wire connection. Connect the wires as follows:

  • สายสีแดง: VCC (+) - Connect to DC 5V to 24V power supply.
  • สายสีดำ: GND (-) - Connect to ground.
  • สายสีเหลือง: Signal Output - Connect to your microcontroller or data acquisition system's input pin.

ตรวจสอบปริมาณการใช้งานtage is within the specified range of DC 5-24V. The current drawn by the sensor should not exceed 10mA at 5V DC.

DIGITEN G1 Water Flow Sensor with red, black, and yellow wires connected

รูปที่ 3: ระยะใกล้ view of the sensor's wiring connections: Red (VCC), Black (GND), and Yellow (Signal).

Close-up of the 3-pin connector for the DIGITEN G1 Water Flow Sensor

รูปที่ 4: รายละเอียด view of the 3-pin connector attached to the sensor's cable.

คำแนะนำการใช้งาน

หลักการทำงาน

The DIGITEN G1 Water Flow Sensor uses a Hall effect sensor to detect the rotation of an internal turbine. As water flows through the sensor, it spins a turbine, and a magnet attached to the turbine generates a series of electrical pulses. The frequency of these pulses is directly proportional to the flow rate of the water.

Flow Rate Calculation

The output signal is a square wave. The flow rate (Q in L/min) can be calculated from the measured frequency (F in Hz) using the following formula:

F = 4.8 * Q (L/min)

Therefore, to find the flow rate:

Q (L/min) = F / 4.8

The sensor provides approximately 450 pulses per liter of water. The accuracy is ±2%.

DIGITEN G1 Water Flow Sensor showing internal turbine

รูปที่ 5: ภายใน view of the sensor, highlighting the turbine mechanism responsible for pulse generation.

DIGITEN G1 Water Flow Sensor with clear label and connections

Figure 6: The sensor with its label clearly visible, detailing model number, working range, and wiring information.

การซ่อมบำรุง

  • การตรวจสอบปกติ: Periodically check for any signs of leaks at the connections or damage to the sensor body and wiring.
  • การทำความสะอาด: If the sensor's accuracy degrades, it may be due to debris accumulation inside the turbine. Disconnect power and water supply, then carefully remove the sensor for inspection and cleaning. Use a soft brush and clean water to remove any obstructions.
  • พื้นที่จัดเก็บ: If storing the sensor for an extended period, ensure it is clean, dry, and kept within the specified storage temperature and humidity ranges (-25°C to +80°C, 25%-95% RH).

การแก้ไขปัญหา

ปัญหาสาเหตุที่เป็นไปได้สารละลาย
ไม่มีสัญญาณออก
  • Incorrect wiring (VCC, GND, Signal)
  • ไม่มีแหล่งจ่ายไฟ
  • เซ็นเซอร์ทำงานผิดปกติ
  • ไม่มีน้ำไหล
  • Check wiring against the diagram.
  • ตรวจสอบว่าแหล่งจ่ายไฟ (DC 5-24V) เชื่อมต่อและใช้งานได้แล้ว
  • Ensure water is flowing through the sensor.
  • ถ้าเป็นไปได้ ให้ทดสอบกับเซ็นเซอร์ที่ใช้งานได้ดีแล้ว
Inaccurate flow readings
  • Debris inside the sensor
  • ฟองอากาศในท่อน้ำ
  • Incorrect frequency calculation formula
  • Sensor installed incorrectly (e.g., against flow direction)
  • ทำความสะอาดเซ็นเซอร์ตามวิธีที่อธิบายไว้ในส่วนการบำรุงรักษา
  • Bleed air from the water system.
  • Double-check the calculation formula (F = 4.8 * Q).
  • Verify the flow direction arrow on the sensor.
รอยรั่วที่จุดเชื่อมต่อ
  • สารซีลเกลียวไม่เพียงพอ
  • การเชื่อมต่อหลวม
  • เกลียวเสียหาย
  • Reapply thread sealant (PTFE tape) and retighten.
  • Ensure connections are snug.
  • ตรวจสอบเกลียวว่ามีรอยชำรุดหรือไม่ หากจำเป็นให้เปลี่ยนใหม่

การรับประกันและการสนับสนุน

For warranty information or technical support, please contact DIGITEN customer service through the retailer where the product was purchased or visit the official DIGITEN website. Please have your product model number (FL-808) and purchase details ready when contacting support.

© 2023 DIGITEN สงวนลิขสิทธิ์ทุกประการ

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.