Copeland CR35K6E-TF5-875

คู่มือผู้ใช้คอมเพรสเซอร์แบบปิดผนึก Copeland รุ่น CR35K6E-TF5-875

Model: CR35K6E-TF5-875

1. บทนำ

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Copeland Hermetic Compressor, Model CR35K6E-TF5-875. This compressor is designed for use in various refrigeration and air conditioning applications, including packaged systems, geothermal, and heat pump applications. Please read this manual thoroughly before attempting any procedures to ensure proper handling and to prevent potential hazards.

The Copeland CR series compressors are known for their efficiency, durability, and reliability in systems requiring a wide range of evaporative capacity.

2. ข้อมูลด้านความปลอดภัย

คำเตือน: Installation, service, and maintenance of this compressor must be performed by qualified and experienced personnel only. Failure to comply with safety instructions can result in serious injury, death, or property damage.

  • ถอดปลั๊กไฟทุกครั้งก่อนซ่อมบำรุงเครื่อง
  • สวมใส่อุปกรณ์ป้องกันส่วนบุคคล (PPE) ที่เหมาะสม รวมถึงแว่นตาและถุงมือเพื่อความปลอดภัย
  • Handle refrigerants with care. Refer to local regulations for proper handling and disposal.
  • ต้องแน่ใจว่ามีการระบายอากาศที่เหมาะสมเมื่อทำงานกับสารทำความเย็น
  • Do not operate the compressor if any components are damaged.
  • This compressor operates at high voltage (208/230V, 3 Phase). Exercise extreme caution.
Copeland Hermetic Compressor CR35K6E-TF5-875 front view

รูปที่ 1 : ด้านหน้า view of the Copeland Hermetic Compressor CR35K6E-TF5-875. This image shows the main body of the compressor, electrical connection box, and refrigerant line connections.

3. ข้อมูลจำเพาะ

คุณสมบัติ รายละเอียด
หมายเลขรุ่น CR35K6E-TF5-875
ยี่ห้อ โคป
สารทำความเย็น R22
ความจุ 35,000 BtuH at 45°F
เล่มที่tage 208/230โวลต์
เฟส 3 (สาม)
Connection Size (Suction) 3/4" Sweat
Connection Size (Liquid) 1/2" Sweat
ฐานติดตั้ง 7-1/2" x 7-1/2"
คุณสมบัติพิเศษ Hermetic Design
แหล่งพลังงาน Electric, Corded Electric
การใช้ที่แนะนำ Industrial systems, geothermal, heat pump applications
ผู้ผลิต โคป
สี สีดำ
Copeland Hermetic Compressor CR35K6E-TF5-875 side view

รูปที่ 2: ด้านข้าง view of the Copeland Hermetic Compressor CR35K6E-TF5-875, showing the lower refrigerant line connections and mounting feet.

4. การตั้งค่าและการติดตั้ง

Installation of the Copeland Hermetic Compressor requires specialized knowledge and tools. It is strongly recommended that installation be performed by a certified HVAC technician.

4.1 การตรวจสอบก่อนการติดตั้ง

  • Verify that the compressor model matches the system requirements (refrigerant type, voltage, capacity).
  • Inspect the compressor for any shipping damage. Do not install if damage is present.
  • Ensure the mounting surface is level and capable of supporting the compressor's weight.
  • Confirm that the electrical supply matches the compressor's voltage and phase requirements (208/230V, 3 Phase).

4.2 การติดตั้ง

  1. Position the compressor on the designated mounting base (7-1/2" x 7-1/2").
  2. Secure the compressor using appropriate vibration isolation mounts to minimize noise and stress on refrigerant lines.

4.3 การเชื่อมต่อท่อสารทำความเย็น

  • Connect the 3/4" suction line and 1/2" liquid line using proper brazing techniques.
  • Ensure all connections are leak-free. Use nitrogen purge during brazing to prevent oxidation.
  • Evacuate the system to a deep vacuum (typically 500 microns or less) to remove non-condensable gases and moisture.
  • Charge the system with the correct type and amount of R22 refrigerant as specified by the system manufacturer.

4.4 เดินสายไฟฟ้า

  • Connect the 208/230V, 3-phase power supply to the compressor's electrical terminals according to the wiring diagram provided with the system.
  • ตรวจสอบให้แน่ใจว่าการเชื่อมต่อไฟฟ้าทั้งหมดแน่นหนาและปลอดภัย
  • Install appropriate overcurrent protection devices.
  • Verify correct phase rotation for 3-phase compressors to ensure proper motor operation.

5. คู่มือการใช้งาน

Once properly installed and charged, the compressor will operate as part of the overall refrigeration or air conditioning system. The following are general operating principles:

  • The compressor is designed to cycle on and off based on the system's thermostat or control signals to maintain desired temperature.
  • Ensure the system is adequately charged with R22 refrigerant. Low or high refrigerant levels can lead to inefficient operation or damage.
  • Monitor system pressures and temperatures to ensure operation within design limits.
  • ควรหลีกเลี่ยงการเปิด-ปิดเครื่องบ่อยๆ ในระยะเวลาสั้นๆ เพราะอาจทำให้คอมเพรสเซอร์มีอายุการใช้งานสั้นลง

6. การบำรุงรักษา

Regular maintenance is crucial for the longevity and efficient operation of your Copeland compressor. All maintenance should be performed by qualified personnel.

6.1 การตรวจสอบตามปกติ (รายเดือน/รายไตรมาส)

  • ตรวจสอบดูว่ามีเสียงผิดปกติหรือการสั่นสะเทือนใดๆ ระหว่างการใช้งาน
  • Check for refrigerant leaks using an electronic leak detector.
  • Monitor system pressures and temperatures.
  • Inspect electrical connections for tightness and signs of overheating.

6.2 การบำรุงรักษาประจำปี

  • Perform a comprehensive system check, including refrigerant charge verification.
  • Clean the condenser and evaporator coils to ensure optimal heat transfer.
  • Check the compressor oil level and condition if accessible and recommended by the system manufacturer.

7 การแก้ไขปัญหา

ส่วนนี้ให้คำแนะนำทั่วไปเกี่ยวกับปัญหาที่พบบ่อย สำหรับปัญหาที่ซับซ้อน โปรดปรึกษาช่างเทคนิคผู้เชี่ยวชาญ

7.1 Compressor Not Starting

  • ไม่มีไฟฟ้า: Check circuit breakers, fuses, and electrical connections.
  • Control Issue: Verify thermostat settings and control board signals.
  • ระบบป้องกันการโอเวอร์โหลด: Compressor may be tripped on internal overload. Allow time to cool and reset. Investigate cause of overload (e.g., high head pressure, low voltagจ).
  • การเดินสายไฟไม่ถูกต้อง: Ensure correct 3-phase wiring and phase rotation.

7.2 Insufficient Cooling/Heating

  • Low Refrigerant Charge: Check for leaks and recharge system.
  • Dirty Coils: ทำความสะอาดคอยล์คอนเดนเซอร์และคอยล์ระเหย
  • Airflow Restrictions: Check filters and ductwork.
  • Compressor Malfunction: If compressor runs but does not pump effectively, it may indicate internal damage.

7.3 เสียงดังหรือการสั่นสะเทือนมากเกินไป

  • การติดตั้งแบบหลวม: Check and tighten mounting bolts.
  • Refrigerant Slugging: Ensure proper superheat and subcooling.
  • Internal Compressor Issue: If noise persists, the compressor may require replacement.

8. การกำจัด

When the compressor reaches the end of its service life, it must be disposed of in accordance with all local, state, and federal regulations. Refrigerants must be recovered by certified technicians before disposal. Do not vent refrigerants into the atmosphere.

9. การรับประกันและการสนับสนุน

Information regarding the specific warranty terms for the Copeland Hermetic Compressor CR35K6E-TF5-875 was not available in the provided product data. For warranty details and technical support, please contact your authorized Copeland distributor or the point of purchase. Ensure you have your model number (CR35K6E-TF5-875) and serial number ready when seeking support.

Genuine Copeland Compressor seal

Figure 3: Seal indicating a genuine Copeland Compressor. Always ensure you are using authentic Copeland parts for optimal performance and reliability.

© 2023 โคปแลนด์ สงวนลิขสิทธิ์ทุกประการ

คู่มือนี้มีวัตถุประสงค์เพื่อให้ข้อมูลเท่านั้น ข้อมูลจำเพาะอาจมีการเปลี่ยนแปลงโดยไม่ต้องแจ้งให้ทราบล่วงหน้า

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.