This manual provides detailed instructions for the proper setup, operation, and maintenance of your AmScope T720 Trinocular Compound Microscope. Please read this manual thoroughly before using the instrument to ensure optimal performance and longevity.

ข้อมูลด้านความปลอดภัย

  • ความปลอดภัยทางไฟฟ้า: Ensure the microscope is connected to a power source within the specified voltage range (90-240V). Always unplug the microscope before cleaning or performing maintenance.
  • การจัดการ: Handle the microscope with care. Avoid sudden impacts or vibrations.
  • สิ่งแวดล้อม: Use the microscope in a clean, dry, and dust-free environment. Avoid exposure to direct sunlight or extreme temperatures.
  • ส่วนประกอบทางแสง: Do not touch optical surfaces with bare hands. Use specialized lens cleaning materials.

เนื้อหาแพ็คเกจ

ตรวจสอบว่ามีสินค้าทั้งหมดที่ระบุไว้ด้านล่างอยู่ในแพ็คเกจของคุณ:

  • Microscope (Main Body)
  • หัวกล้องสามตา
  • Plan Achromatic Objectives (4X, 10X, 40X, 100X)
  • Extreme Widefield Eyepieces (10X pair)
  • สายไฟ
  • ผ้าคลุมป้องกันฝุ่น
  • Immersion Oil (for 100X objective)
  • คู่มือการใช้งาน (เอกสารนี้)

สินค้าเกินview

The AmScope T720 is a professional trinocular compound microscope designed for advanced laboratory and research applications. It features a Plan Infinity optical system, providing crisp and clear images across the entire field of view.

ด้านหน้าซ้าย view of the AmScope T720 Trinocular Compound Microscope

ด้านหน้าซ้าย view of the AmScope T720 Trinocular Compound Microscope, showcasing the trinocular head, eyepieces, revolving nosepiece with objectives, mechanical stagและฐานที่มีปุ่มควบคุมแสงสว่าง

คุณสมบัติหลัก:

  • ระบบออปติคอล: Plan Infinity optical system for high-quality, sharp images.
  • กำลังขยาย: Four magnification settings: 40X, 100X, 400X, and 1000X.
  • เลนส์สายตา: Extreme widefield 10X eyepieces.
  • วัตถุประสงค์: Four Plan Achromatic objectives (4X, 10X, 40X, 100X).
  • จมูก: Backward nosepiece configuration for ampพื้นที่ทำงาน
  • การให้แสงสว่าง: Wide band voltage (90-240V) Kohler LED illumination system with iris condenser.
  • ศีรษะ: 30-degree inclined, 360-degree swiveling, compensation-free trinocular head.
  • การโฟกัส: Coaxial coarse and fine focusing system.
  • Stage: 3D mechanical stage.
  • พอร์ต Trinocular: Dedicated port for attaching a camera or video device.
Another perspective of the AmScope T720 microscope

Another perspective of the AmScope T720 microscope, showing the overall structure and the placement of the illumination and stage control mechanisms.

การตั้งค่า

1. การแกะกล่องและการจัดวาง:

Carefully remove all components from the packaging. Place the microscope on a stable, level surface away from direct sunlight, heat sources, and vibrations.

2. Head Assembly:

Loosen the set screw on the top of the microscope body. Gently insert the trinocular head into the opening, ensuring it is fully seated. Tighten the set screw to secure the head. The head can be rotated 360 degrees for comfortable viewการไอเอ็นจี

3. Eyepiece Installation:

Remove the protective caps from the eyepiece tubes on the trinocular head. Insert the two 10X widefield eyepieces into the tubes. If dust caps are present, remove them.

4. Objective Installation:

Rotate the revolving nosepiece until the lowest power objective (4X) is positioned over the stage opening. Screw the 4X, 10X, 40X, and 100X Plan Achromatic objectives into the nosepiece in increasing order of magnification. Ensure they are securely tightened.

5. การเชื่อมต่อไฟฟ้า:

Connect the power cord to the microscope's power input and then to a suitable electrical outlet (90-240V AC).

ด้านข้าง view of the AmScope T720 Trinocular Compound Microscope

ด้านข้าง view of the AmScope T720 Trinocular Compound Microscope, highlighting the ergonomic design of the stand and the position of the coarse and fine focus knobs.

คำแนะนำการใช้งาน

1. Power On and Illumination:

Turn on the main power switch, usually located at the base of the microscope. Adjust the brightness control knob to achieve comfortable illumination. The Kohler illumination system provides even and bright lighting for optimal viewการไอเอ็นจี

2. Specimen Placement:

วางสไลด์ตัวอย่างที่เตรียมไว้ลงบนแท่นรองเชิงกลtage. ใช้ stage clips to hold the slide securely in place. Use the X-Y stage control knobs to center the specimen area you wish to observe under the objective lens.

3. การมุ่งเน้น:

  1. การโฟกัสแบบหยาบ: Begin with the 4X objective. Use the coarse focus knob to bring the specimen into approximate focus.
  2. โฟกัสละเอียด: Once roughly focused, use the fine focus knob for precise focusing. This knob allows for minute adjustments to achieve a sharp image.
  3. Interpupillary Distance and Diopter Adjustment: Adjust the interpupillary distance by moving the eyepiece tubes until a single, circular field of view is observed. If one eye requires a different focus, use the diopter adjustment ring on one of the eyepieces to compensate.

4. Changing Magnification:

To increase magnification, rotate the revolving nosepiece to the next higher objective (e.g., from 4X to 10X). Due to the Plan Infinity optical system, the image should remain largely in focus, requiring only minor adjustments with the fine focus knob. When using the 100X objective, apply a small drop of immersion oil directly onto the specimen slide before rotating the 100X objective into position. Ensure the objective lens makes contact with the oil.

5. Using the Trinocular Port:

The trinocular port allows for the attachment of a microscope camera or other imaging device. To direct light to the trinocular port, pull out the light path selector rod (if present) on the side of the head. Refer to your camera's manual for specific attachment and operation instructions.

ภาพระยะใกล้ view of the AmScope T720 microscope's objectives and mechanical stage

ภาพระยะใกล้ view of the AmScope T720 microscope's revolving nosepiece with Plan Achromatic objectives (4X, 10X, 40X, 100X) and the mechanical stage, illustrating the ample working distance provided by the backward nosepiece.

การซ่อมบำรุง

1. การทำความสะอาด:

  • ส่วนประกอบทางแสง: Use a soft brush or air blower to remove dust from lenses. For smudges, use lens cleaning paper and a small amount of lens cleaning solution. Wipe gently in a circular motion. Never use abrasive materials or harsh solvents.
  • ร่างกาย: เช็ดตัวกล้องจุลทรรศน์ด้วยผ้าเนื้อนุ่มและแห้งamp ผ้า. หลีกเลี่ยงไม่ให้ความชื้นเข้าไปในชิ้นส่วนอิเล็กทรอนิกส์
  • น้ำมันแช่: After using the 100X objective, clean the objective lens and the slide immediately with lens cleaning paper and solution to prevent oil from hardening.

2. การจัดเก็บ:

When not in use, cover the microscope with the provided dust cover to protect it from dust and debris. Store it in a cool, dry place.

3. การตรวจสอบเป็นประจำ:

Periodically check all screws and moving parts for tightness. Do not overtighten.

การแก้ไขปัญหา

ปัญหาสาเหตุที่เป็นไปได้สารละลาย
ไม่มีแสงสว่างPower cord disconnected, power switch off, bulb failureCheck power connection, turn on switch, contact support for bulb replacement.
Image is blurry or won't focusIncorrect focusing, objective not fully engaged, dirty lens, slide upside downAdjust coarse and fine focus, rotate nosepiece until objective clicks into place, clean lenses, ensure slide cover slip is up.
จุดด่างดำในทุ่งนา viewDust on eyepiece, objective, or condenserClean eyepieces, objectives, and condenser. Rotate eyepiece to see if spots move.
ภาพมืดเกินไปหรือสว่างเกินไปIllumination intensity incorrect, iris diaphragm setting incorrectAdjust brightness control, adjust iris diaphragm for optimal contrast.
Difficulty with 100X objectiveNo immersion oil, air bubbles in oil, incorrect oil typeEnsure a drop of immersion oil is used, remove air bubbles by gently rotating objective, use only specified immersion oil.

ข้อมูลจำเพาะ

คุณสมบัติรายละเอียด
แบบอย่างT720
ระบบออปติคอลPlan Infinity
ศีรษะTrinocular, 30-degree inclined, 360-degree swiveling
เลนส์สายตาWF10X (Extreme Widefield)
วัตถุประสงค์Plan Achromatic 4X, 10X, 40X (Spring), 100X (Spring, Oil)
การขยายภาพ40X, 100X, 400X, 1000X
จมูกBackward, Revolving
Stage3D Mechanical Stage
การโฟกัสCoaxial Coarse & Fine Adjustment
การส่องสว่างKohler LED, Wide Band Voltagอี (90-240V)
ประเภทแหล่งกำเนิดแสงนำ
วัสดุGlass (Optical Components)
น้ำหนักสินค้า28 ปอนด์ (12.7 กก.)
ขนาดแพ็คเกจ22.44 x 20.87 x 10.24 นิ้ว

การรับประกันและการสนับสนุน

For warranty information, technical support, or service inquiries, please contact AmScope customer service. Refer to the official AmScope webโปรดตรวจสอบเว็บไซต์หรือเอกสารการซื้อของคุณเพื่อดูรายละเอียดการติดต่อและเงื่อนไขการรับประกันล่าสุด

นอกจากนี้ อาจมีแหล่งข้อมูลออนไลน์และคำถามที่พบบ่อย (FAQ) ให้บริการบนเว็บไซต์ด้วย AmScope Store.