Hygiena SS3

Hygiena SystemSURE Plus ATP Monitoring System User Manual

แบบ: SS3

1. สินค้าหมดview

The Hygiena SystemSURE Plus is an advanced ATP (Adenosine Triphosphate) hygiene monitoring system designed for rapid and accurate assessment of surface and liquid cleanliness. This next-generation system builds upon the success of the SystemSURE II, offering enhanced functionality, new software capabilities, and increased memory to meet diverse operational demands.

คุณสมบัติหลัก:

  • Sensitive Detection: Detects down to 1 femtomole (1 x 10-15 moles) of ATP, ensuring high accuracy in hygiene monitoring.
  • Advanced Photodiode Technology: Features an internal solid-state detector that maintains performance stability, unaffected by drops or shakes.
  • ขนาดกะทัดรัดและพกพาสะดวก: Small, lightweight, and handheld design for ease of use in various environments.
  • อายุการใช้งานแบตเตอรี่ที่ยาวนานขึ้น: Powered by 2 x AA batteries, providing several months of uninterrupted operation.
  • การบำรุงรักษาที่ง่ายดาย: Removable read chamber design facilitates simple and thorough cleaning.
Hygiena SystemSURE Plus ATP Monitoring System handheld device

Figure 1: The Hygiena SystemSURE Plus ATP Monitoring System, a handheld device for hygiene monitoring.

2. การตั้งค่า

2.1 การแกะบรรจุภัณฑ์และการตรวจสอบ

Carefully unpack all components from the packaging. Verify that all items listed in the packing slip are present and undamaged. If any components are missing or damaged, contact Hygiena customer support immediately.

2.2 การติดตั้งแบตเตอรี่

  1. Locate the battery compartment cover on the back of the SystemSURE Plus device.
  2. Slide the cover open or remove it according to the indicator.
  3. ใส่แบตเตอรี่ AA สอง (2) ก้อน โดยตรวจสอบให้แน่ใจว่าขั้วถูกต้อง (+/-) ตามที่ระบุไว้ภายในช่องใส่แบตเตอรี่
  4. ใส่ฝาปิดช่องใส่แบตเตอรี่กลับเข้าที่อย่างแน่นหนา

2.3 SureTrend Software Installation

The SureTrend software is essential for data management and analysis. Install the software on a compatible computer by following the instructions provided with the software package or by downloading the latest version from the official Hygiena webตรวจสอบให้แน่ใจว่าคอมพิวเตอร์ของคุณตรงตามข้อกำหนดขั้นต่ำของระบบ

2.4 การเปิดเครื่องครั้งแรก

Press and hold the power button (usually marked with a circle or 'P') until the device screen illuminates. The device will perform a self-test. Once complete, the main menu or ready screen will appear.

Hygiena SystemSURE Plus ATP Monitoring System held in a hand

Figure 2: The SystemSURE Plus device comfortably held in a user's hand, demonstrating its portability.

3. คู่มือการใช้งาน

3.1 Performing an ATP Test

  1. Power on the SystemSURE Plus device.
  2. Select the desired test plan or location using the navigation buttons.
  3. Take a Hygiena ATP test swab (e.g., UltraSnap, AquaSnap) and follow its specific instructions for collecting a sample from the surface or liquid to be tested.
  4. Activate the swab by breaking the Snap-Valve and squeezing the liquid down the swab shaft. Shake gently.
  5. Insert the activated swab into the SystemSURE Plus read chamber. Ensure it is fully seated.
  6. Close the chamber lid and press the 'OK' button to initiate the test.
  7. The device will display the RLU (Relative Light Unit) reading after a 15-second countdown.

3.2 การตีความผลลัพธ์

The RLU value indicates the level of ATP detected. Higher RLU values correspond to higher levels of biological contamination. Refer to your organization's established pass/fail limits for ATP readings to determine the cleanliness status of the tested area.

3.3 Data Transfer to SureTrend

Connect the SystemSURE Plus device to your computer using the provided USB cable. Open the SureTrend software. Follow the software prompts to synchronize data from the device to the computer for detailed analysis, trending, and reporting.

4. การบำรุงรักษา

4.1 การทำความสะอาดเครื่อง

Regular cleaning ensures optimal performance and longevity of your SystemSURE Plus. Use a soft, damp cloth with a mild, non-abrasive cleaner to wipe the exterior of the device. Avoid harsh chemicals or solvents.

4.2 Cleaning the Read Chamber

The SystemSURE Plus features a removable read chamber for easy cleaning. To clean:

  1. ตรวจสอบให้แน่ใจว่าอุปกรณ์ปิดอยู่
  2. Carefully remove the read chamber according to the device's design (refer to the diagram in the full manual if needed).
  3. Clean the chamber using a lint-free cloth and isopropyl alcohol. Ensure no debris or liquid remains.
  4. Allow the chamber to dry completely before reinserting it into the device.

4.3 การเปลี่ยนแบตเตอรี่

When the low battery indicator appears on the screen, replace both AA batteries promptly to avoid interruption of operation and potential data loss. Refer to section 2.2 for battery installation instructions.

4.4 พื้นที่จัดเก็บ

Store the SystemSURE Plus in a clean, dry environment at room temperature. Avoid extreme temperatures, humidity, and direct sunlight. If storing for extended periods, remove the batteries.

Hygiena SystemSURE Plus ATP Monitoring System on a charging stand

Figure 3: The SystemSURE Plus device resting on its stand, suitable for storage or charging (if applicable).

5 การแก้ไขปัญหา

5.1 อุปกรณ์ไม่เปิดเครื่อง

  • ตรวจสอบการติดตั้งแบตเตอรี่และให้แน่ใจว่าขั้วถูกต้อง
  • เปลี่ยนแบตเตอรี่ AA ใหม่
  • ตรวจสอบให้แน่ใจว่าได้กดปุ่มเปิด/ปิดค้างไว้นานพอ

5.2 Inaccurate or Inconsistent Readings

  • Verify that ATP test swabs are not expired and have been stored correctly.
  • Ensure the read chamber is clean and free of debris (refer to section 4.2).
  • Confirm proper sample collection and swab activation techniques.
  • Perform a calibration check if available (refer to the full SureTrend manual for calibration procedures).

5.3 SureTrend Software Connection Issues

  • ตรวจสอบให้แน่ใจว่าสาย USB เชื่อมต่อกับอุปกรณ์และคอมพิวเตอร์อย่างแน่นหนา
  • Verify that the SureTrend software is running and updated to the latest version.
  • Check your computer's device manager for proper recognition of the SystemSURE Plus.
  • รีสตาร์ททั้งอุปกรณ์และคอมพิวเตอร์

For persistent issues, contact Hygiena customer support.

6. ข้อมูลจำเพาะ

ชื่อยี่ห้อสุขอนามัย
หมายเลขรุ่นSS3
ขนาดรายการ (ยาว x กว้าง x สูง)7.01 x 1.18 x 2.99 นิ้ว
น้ำหนักสินค้า9.12 ออนซ์
แหล่งพลังงานแบตเตอรี่ AA 2 ก้อน
ATP Detection Sensitivity1 femtomole (1 x 10-15 moles)
ผู้ผลิตสุขอนามัย

7. ข้อมูลการรับประกัน

The Hygiena SystemSURE Plus ATP Monitoring System is covered by a manufacturer's warranty. Specific warranty terms and conditions, including duration and coverage details, are provided with your product documentation. Please retain your proof of purchase for warranty claims. For detailed warranty information, refer to the official Hygiena webไซต์หรือติดต่อฝ่ายสนับสนุนลูกค้า

8. การสนับสนุน

For technical assistance, product inquiries, or to order accessories and consumables, please contact Hygiena customer support. You can find contact information and additional resources, including FAQs and software updates, on the official Hygiena Store on Amazon or the main Hygiena corporate webเว็บไซต์.

© 2024 Hygiena สงวนลิขสิทธิ์ทุกประการ ข้อมูลอาจเปลี่ยนแปลงได้โดยไม่ต้องแจ้งให้ทราบล่วงหน้า

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.