HighPoint RocketRAID 2720SGL

HighPoint RocketRAID 2720SGL 8-Port SAS 6Gb/s RAID HBA User Manual

Model: RocketRAID 2720SGL

1. บทนำ

The HighPoint RocketRAID 2720SGL is an 8-Port SAS 6Gb/s PCIe 2.0 x8 RAID Host Bus Adapter designed for high-performance storage solutions. This adapter supports both SAS and SATA devices, offering a range of RAID configurations including RAID 0, 1, 5, 10, 50, and JBOD. It is compatible with major operating systems such as Windows, Linux, and FreeBSD, and features a unified web-based management interface for easy configuration and monitoring.

คุณสมบัติหลัก:

  • 6Gb/s (600MB/s) data transfer rate.
  • PCI-Express 2.0 x8 interface.
  • 2 Internal Mini-SAS ports (SFF-8087) supporting up to 8 SAS/SATA drives.
  • Supports RAID levels 0, 1, 5, 10, 50, and JBOD.
  • Hot-swap and hot-plug capabilities.
  • Comprehensive OS support for Windows, Linux, and FreeBSD.
  • รวมเป็นหนึ่ง Web- การจัดการตาม (Web GUI) and Command Line Interface (CLI).
  • Advanced RAID features including Online Capacity Expansion (OCE) and Online RAID Level Migration (ORLM).
  • S.M.A.R.T. array monitoring and alerts.
HighPoint RocketRAID 2720SGL RAID HBA card
Figure 1: HighPoint RocketRAID 2720SGL 8-Port SAS 6Gb/s RAID HBA.

This image displays the HighPoint RocketRAID 2720SGL card, featuring its green PCB, golden heatsink, and two internal Mini-SAS (SFF-8087) ports. The PCIe x8 connector is visible at the bottom, along with a low-profile วงเล็บ

2. เนื้อหาบรรจุภัณฑ์

Verify that all items are present in your RocketRAID 2720SGL package:

  • RocketRAID 2720 Host Adapter
  • คู่มือการติดตั้งแบบด่วน
  • ซีดีซอฟแวร์
  • โปรต่ำfile วงเล็บ

Note: Mini-SAS to SATA cables are not included with the SGL package and must be purchased separately.

HighPoint RocketRAID 2720SGL product packaging
Figure 2: HighPoint RocketRAID 2720SGL product packaging.

This image shows the white retail box for the HighPoint RocketRAID 2720SGL, featuring the HighPoint Technologies logo and a product label with the model name and barcode.

3. การตั้งค่าและการติดตั้ง

3.1 การติดตั้งทางกายภาพ

  1. ระบบปิดเครื่อง: Ensure your computer system is completely powered off and disconnected from the power source.
  2. โครงตัวถังแบบเปิด: Open the computer chassis to access the motherboard's PCIe slots.
  3. ใส่ HBA: Locate an available PCI-Express 2.0 x8 slot or higher (e.g., x16) and carefully insert the RocketRAID 2720SGL HBA until it is firmly seated.
  4. บัตรที่ปลอดภัย: Secure the HBA with the bracket screw. If using a low-profile chassis, replace the standard bracket with the included low-profile วงเล็บ
  5. เชื่อมต่อไดรฟ์: Connect your SAS or SATA drives to the two internal Mini-SAS (SFF-8087) ports on the HBA using appropriate Mini-SAS to SATA breakout cables (not included). Each port supports up to four drives.
  6. ปิดแชสซี: ปิดฝาเคสคอมพิวเตอร์และเสียบปลั๊กไฟกลับเข้าไปใหม่
HighPoint RocketRAID 2720SGL showing Mini-SAS ports
Figure 3: Close-up of RocketRAID 2720SGL showing internal Mini-SAS ports.

ภาพนี้ให้รายละเอียด view of the HighPoint RocketRAID 2720SGL, highlighting the two internal Mini-SAS (SFF-8087) connectors where storage drives are attached. The golden heatsink and various electronic components are also visible.

3.2 การติดตั้งไดรเวอร์

After physical installation, power on your system. The operating system will detect new hardware. Install the appropriate drivers from the included Software CD or download the latest drivers from the HighPoint website for your specific operating system (Windows, Linux, FreeBSD).

  • หน้าต่าง: Follow the on-screen prompts to install drivers. It is recommended to download the latest drivers and Web interface from the HighPoint webเว็บไซต์.
  • Linux/FreeBSD: Refer to the Quick Installation Guide or HighPoint's online documentation for specific driver installation procedures for your distribution.

3.3 BIOS Configuration (Optional)

The RocketRAID 2720SGL has its own BIOS. During system boot, you may see the card's BIOS post screen. Advanced configuration or firmware updates can be performed via the BIOS or the Web GUI. If you encounter boot issues when using multiple RAID controllers, you may need to adjust specific BIOS settings:

  • Access the RocketRAID BIOS by pressing the designated hotkey (often Ctrl-H) during the card's boot-up sequence.
  • If the RocketRAID is ไม่ your boot drive, consider disabling "EBDA Reallocation" and "INT13" settings within the RocketRAID BIOS to prevent conflicts with other controllers.
  • If the RocketRAID is your boot drive, only disable "EBDA Reallocation."
  • บันทึกการเปลี่ยนแปลงและออกจาก BIOS

Note: Firmware updates are often best performed from a bootable DOS environment if conflicts arise with other RAID controllers. Refer to HighPoint's support documentation for detailed instructions on creating a bootable USB for firmware updates.

4. Operating the RocketRAID 2720SGL

4.1 การกำหนดค่า RAID

The RocketRAID 2720SGL supports various RAID levels to optimize performance or data redundancy:

  • RAID 0 (การแบ่งสตริป): Maximizes performance by striping data across multiple drives. No redundancy.
  • RAID 1 (การมิเรอร์): Provides data redundancy by mirroring data onto two drives.
  • RAID 5 (การสตริปด้วย Parity): Offers a balance of performance and data redundancy. Requires at least three drives.
  • RAID 10 (การแบ่งข้อมูลแบบสไตรปิ้ง): ผสานการทำงานของ RAID 0 และ RAID 1 เพื่อประสิทธิภาพและความปลอดภัยของข้อมูล ต้องใช้ฮาร์ดไดรฟ์อย่างน้อยสี่ตัว
  • RAID 50 (Striping of RAID 5 arrays): Combines RAID 0 and RAID 5 for higher performance and redundancy with more drives.
  • JBOD (แค่กลุ่มของดิสก์): Treats individual drives as separate entities without RAID functionality.

RAID arrays can be configured using the Web GUI, CLI, or the card's BIOS utility.

4.2 อินเทอร์เฟซการจัดการ

HighPoint provides several tools for managing your RAID arrays:

  • Web GUI (HighPoint RAID Management - HRM): A web browser-based interface for local and remote monitoring and configuration. Access typically via a specific IP address or localhost port after driver installation.
  • CLI (อินเทอร์เฟซบรรทัดคำสั่ง): For advanced users and scripting, allowing management through command-line commands.
  • BIOS Utility: Accessible during system boot (Ctrl-H) for basic RAID creation and management before the operating system loads.

คุณสมบัติขั้นสูง 4.3 ประการ

  • การขยายขีดความสามารถออนไลน์ (OCE): Allows expanding the capacity of an existing RAID array by adding more drives without data loss or downtime.
  • การย้ายข้อมูลระดับ RAID ออนไลน์ (ORLM): Enables changing the RAID level of an existing array (e.g., from RAID 0 to RAID 5) without data loss.
  • Native Command Queuing (NCQ): Optimizes the order of read/write commands for improved performance with SATA drives.
  • SMART (เทคโนโลยีการตรวจสอบ วิเคราะห์ และรายงานตนเอง): Monitors drive health and predicts potential failures.
  • Disk Scrubbing: A process to verify data integrity and correct errors on RAID arrays.
  • 64-bit LBA Support: For RAID arrays larger than 2TB.

5. การบำรุงรักษาและการตรวจสอบ

Regular monitoring of your RAID array and connected drives is crucial for data integrity and system stability.

5.1 Array Monitors, Alerts, and Indicators

  • Hard Drive LED Indicators: Activity and Failed LEDs (if applicable to your system/enclosure) provide visual status.
  • SMTP Email Notification: Configure email alerts for critical events and error reporting.
  • Alarm/Buzzer Alerts: Audible alerts for drive or array failures.
  • SAF-TE (I2C) and SGPIO: Enclosure management support for compatible drive enclosures.
  • SHI (Storage Health Inspector): Drive analysis driven from S.M.A.R.T. data for proactive maintenance.

5.2 ความเข้ากันได้ของไดรฟ์

For optimal performance and reliability, it is recommended to use enterprise-grade or RAID-specific hard drives. Desktop-class drives may exhibit unexpected behavior or become unresponsive under heavy load in a RAID environment due to differences in error recovery control (ERC) or Time-Limited Error Recovery (TLER) features.

6 การแก้ไขปัญหา

This section addresses common issues you might encounter with the RocketRAID 2720SGL.

6.1 System Fails to Boot or Hangs at POST

  • Multiple RAID Controllers: If you have another RAID controller in your system, conflicts can occur. Try disabling "EBDA Reallocation" and "INT13" in the RocketRAID BIOS if it's not your boot drive. If it is your boot drive, disable only "EBDA Reallocation."
  • การเข้าถึง BIOS: If the system hangs before you can access the RocketRAID BIOS (often by pressing Ctrl-H), try pressing the จบ key immediately when the RocketRAID BIOS screen appears to bypass it and proceed with boot.
  • ปัญหาการอัพเดตเฟิร์มแวร์: Ensure firmware is up-to-date. If a Web GUI update caused issues, consider performing the update from a bootable DOS environment as described in HighPoint's support documentation.

6.2 Drives Become Unresponsive or Drop Offline

  • ประเภทไดรฟ์: Using desktop-grade hard drives in a RAID environment can lead to instability. These drives may not handle error recovery in a timely manner, causing the controller to mark them as unresponsive. Use enterprise or RAID-specific drives for best results.
  • การเดินสาย: Ensure all Mini-SAS to SATA breakout cables are securely connected and are of good quality. Faulty cables can cause intermittent drive connectivity issues.
  • ความร้อน: The controller chip can generate significant heat. Ensure adequate airflow within your chassis, especially around the HBA's heatsink. Consider additional cooling if temperatures are consistently high.

6.3 Audible Alarm Sounds Constantly

  • This typically indicates a drive or array failure. Check the Web GUI or BIOS utility for specific error messages.
  • Verify all drives are properly connected and functioning. A drive that is not fully initialized or has errors can trigger the alarm.

7. ข้อมูลจำเพาะ

หมายเลขรุ่นRocketRAID 2720SGL
ฮาร์ดแวร์อินเตอร์เฟซเอสเอเอส
อินเทอร์เฟซ PCIePCI Express 2.0 x8
อัตราการถ่ายโอนข้อมูล6Gb/s (600MB/s) per port
พอร์ต2 Internal Mini-SAS Connectors (SFF-8087)
การสนับสนุนไดรฟ์Up to 8 SAS/SATA drives
ระดับ RAID0, 1, 5, 10, 50, เจบีโอดี
การรองรับระบบปฏิบัติการWindows (XP, 2003, Vista, 2008, 7 - 32/64-bit), Linux (Fedora Core, Red Hat Enterprise/CentOS, SuSE, Debian, Ubuntu), FreeBSD
ฟอร์มแฟกเตอร์โปรต่ำfile การ์ดเสียบปลั๊ก
น้ำหนักสินค้า4.8 ออนซ์

8. ข้อมูลการรับประกัน

The HighPoint RocketRAID 2720SGL comes with a รับประกัน 3 ปี from the manufacturer. Please retain your proof of purchase for warranty claims. For detailed terms and conditions, refer to the official HighPoint webไซต์หรือติดต่อฝ่ายสนับสนุนลูกค้าของพวกเขา

Legal Disclaimer: Device is currently working. DOA (Dead On Arrival) parts will be honored as long as the serial number of the item returned matches.

9. การสนับสนุนและทรัพยากร

For further assistance, updated drivers, firmware, and detailed documentation, please refer to the following resources: